Cargando…

The ICARUS Front-end Preamplifier Working at Liquid Argon Temperature

We describe characteristics and performance of the low-noise front-end preamplifier used in the ICARUS 50-litre liquid Argon Time Projection Chamber installed in the CERN West Area Neutrino Facility during the 1997-98 neutrino runs. The preamplifiers were designed to work immersed in ultra-pure liqu...

Descripción completa

Detalles Bibliográficos
Autores principales: Baibussinov, B., Carpanese, C., Casagrande, F., Cennini, P., Centro, S., Curioni, A., Meng, G., Montanari, C., Picchi, P., Pietropaolo, F., Raselli, G.L., Rubbia, C., Sergiampietri, F., Ventura, S.
Lenguaje:eng
Publicado: 2011
Materias:
Acceso en línea:http://cds.cern.ch/record/1376373
_version_ 1780922965137817600
author Baibussinov, B.
Carpanese, C.
Casagrande, F.
Cennini, P.
Centro, S.
Curioni, A.
Meng, G.
Montanari, C.
Picchi, P.
Pietropaolo, F.
Raselli, G.L.
Rubbia, C.
Sergiampietri, F.
Ventura, S.
author_facet Baibussinov, B.
Carpanese, C.
Casagrande, F.
Cennini, P.
Centro, S.
Curioni, A.
Meng, G.
Montanari, C.
Picchi, P.
Pietropaolo, F.
Raselli, G.L.
Rubbia, C.
Sergiampietri, F.
Ventura, S.
author_sort Baibussinov, B.
collection CERN
description We describe characteristics and performance of the low-noise front-end preamplifier used in the ICARUS 50-litre liquid Argon Time Projection Chamber installed in the CERN West Area Neutrino Facility during the 1997-98 neutrino runs. The preamplifiers were designed to work immersed in ultra-pure liquid Argon at a temperature of 87K.
id cern-1376373
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2011
record_format invenio
spelling cern-13763732023-03-14T20:51:03Zhttp://cds.cern.ch/record/1376373engBaibussinov, B.Carpanese, C.Casagrande, F.Cennini, P.Centro, S.Curioni, A.Meng, G.Montanari, C.Picchi, P.Pietropaolo, F.Raselli, G.L.Rubbia, C.Sergiampietri, F.Ventura, S.The ICARUS Front-end Preamplifier Working at Liquid Argon TemperatureDetectors and Experimental TechniquesWe describe characteristics and performance of the low-noise front-end preamplifier used in the ICARUS 50-litre liquid Argon Time Projection Chamber installed in the CERN West Area Neutrino Facility during the 1997-98 neutrino runs. The preamplifiers were designed to work immersed in ultra-pure liquid Argon at a temperature of 87K.We describe characteristics and performance of the low-noise front-end preamplifier used in the ICARUS 50-litre liquid Argon Time Projection Chamber installed in the CERN West Area Neutrino Facility during the 1997-98 neutrino runs. The preamplifiers were designed to work immersed in ultra-pure liquid Argon at a temperature of 87K.arXiv:1108.3825ICARUS-TM-11-02ICARUS-TM-11-02oai:cds.cern.ch:13763732011-08-19
spellingShingle Detectors and Experimental Techniques
Baibussinov, B.
Carpanese, C.
Casagrande, F.
Cennini, P.
Centro, S.
Curioni, A.
Meng, G.
Montanari, C.
Picchi, P.
Pietropaolo, F.
Raselli, G.L.
Rubbia, C.
Sergiampietri, F.
Ventura, S.
The ICARUS Front-end Preamplifier Working at Liquid Argon Temperature
title The ICARUS Front-end Preamplifier Working at Liquid Argon Temperature
title_full The ICARUS Front-end Preamplifier Working at Liquid Argon Temperature
title_fullStr The ICARUS Front-end Preamplifier Working at Liquid Argon Temperature
title_full_unstemmed The ICARUS Front-end Preamplifier Working at Liquid Argon Temperature
title_short The ICARUS Front-end Preamplifier Working at Liquid Argon Temperature
title_sort icarus front-end preamplifier working at liquid argon temperature
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/1376373
work_keys_str_mv AT baibussinovb theicarusfrontendpreamplifierworkingatliquidargontemperature
AT carpanesec theicarusfrontendpreamplifierworkingatliquidargontemperature
AT casagrandef theicarusfrontendpreamplifierworkingatliquidargontemperature
AT cenninip theicarusfrontendpreamplifierworkingatliquidargontemperature
AT centros theicarusfrontendpreamplifierworkingatliquidargontemperature
AT curionia theicarusfrontendpreamplifierworkingatliquidargontemperature
AT mengg theicarusfrontendpreamplifierworkingatliquidargontemperature
AT montanaric theicarusfrontendpreamplifierworkingatliquidargontemperature
AT picchip theicarusfrontendpreamplifierworkingatliquidargontemperature
AT pietropaolof theicarusfrontendpreamplifierworkingatliquidargontemperature
AT raselligl theicarusfrontendpreamplifierworkingatliquidargontemperature
AT rubbiac theicarusfrontendpreamplifierworkingatliquidargontemperature
AT sergiampietrif theicarusfrontendpreamplifierworkingatliquidargontemperature
AT venturas theicarusfrontendpreamplifierworkingatliquidargontemperature
AT baibussinovb icarusfrontendpreamplifierworkingatliquidargontemperature
AT carpanesec icarusfrontendpreamplifierworkingatliquidargontemperature
AT casagrandef icarusfrontendpreamplifierworkingatliquidargontemperature
AT cenninip icarusfrontendpreamplifierworkingatliquidargontemperature
AT centros icarusfrontendpreamplifierworkingatliquidargontemperature
AT curionia icarusfrontendpreamplifierworkingatliquidargontemperature
AT mengg icarusfrontendpreamplifierworkingatliquidargontemperature
AT montanaric icarusfrontendpreamplifierworkingatliquidargontemperature
AT picchip icarusfrontendpreamplifierworkingatliquidargontemperature
AT pietropaolof icarusfrontendpreamplifierworkingatliquidargontemperature
AT raselligl icarusfrontendpreamplifierworkingatliquidargontemperature
AT rubbiac icarusfrontendpreamplifierworkingatliquidargontemperature
AT sergiampietrif icarusfrontendpreamplifierworkingatliquidargontemperature
AT venturas icarusfrontendpreamplifierworkingatliquidargontemperature