R2E-related MD: slow controlled losses for RadMon/BLM cross-checks

The purpose of the dedicated R2E MD has been to evaluate the R factor (i.e. the ratio between the thermal neutron fluence and the high energy hadron fluence (>20MeV) for various tunnel locations, to measure the HEH radiation level gradient along the MBC dipole and on the MQ, to check the ratio th...

Descripción completa

Detalles Bibliográficos
Autores principales: Calviani, M, Brugger, M, Spiezia, G, Sapinski, M, Priebe, A, Nordt, A, Pojer, M
Lenguaje:eng
Publicado: 2011
Materias:
Acceso en línea:http://cds.cern.ch/record/1376666
_version_ 1780922971812003840
author Calviani, M
Brugger, M
Spiezia, G
Sapinski, M
Priebe, A
Nordt, A
Pojer, M
author_facet Calviani, M
Brugger, M
Spiezia, G
Sapinski, M
Priebe, A
Nordt, A
Pojer, M
author_sort Calviani, M
collection CERN
description The purpose of the dedicated R2E MD has been to evaluate the R factor (i.e. the ratio between the thermal neutron fluence and the high energy hadron fluence (>20MeV) for various tunnel locations, to measure the HEH radiation level gradient along the MBC dipole and on the MQ, to check the ratio the BLM measured dose and RadMon SEU counts and to study the dose gradient between the standard BLM beam axis location and at the level of the equipment location. Within the R2E Mitigation Project, these accurate measurement and cross-check of the mentioned parameters are of great importance for the evaluation and interpretation of the R2E-related radiation levels, as well as for the evaluation of the failure cross-section of specific equipment (i.e. QPS ISO150). In addition, a short part of the MD has been devoted to the comparison of BLM signals generated by loss directed inwards and outwards with respect to the LHC ring.
id cern-1376666
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2011
record_format invenio
spelling cern-13766662019-09-30T06:29:59Zhttp://cds.cern.ch/record/1376666engCalviani, MBrugger, MSpiezia, GSapinski, MPriebe, ANordt, APojer, MR2E-related MD: slow controlled losses for RadMon/BLM cross-checksAccelerators and Storage RingsThe purpose of the dedicated R2E MD has been to evaluate the R factor (i.e. the ratio between the thermal neutron fluence and the high energy hadron fluence (>20MeV) for various tunnel locations, to measure the HEH radiation level gradient along the MBC dipole and on the MQ, to check the ratio the BLM measured dose and RadMon SEU counts and to study the dose gradient between the standard BLM beam axis location and at the level of the equipment location. Within the R2E Mitigation Project, these accurate measurement and cross-check of the mentioned parameters are of great importance for the evaluation and interpretation of the R2E-related radiation levels, as well as for the evaluation of the failure cross-section of specific equipment (i.e. QPS ISO150). In addition, a short part of the MD has been devoted to the comparison of BLM signals generated by loss directed inwards and outwards with respect to the LHC ring.CERN-ATS-Note-2011-070 MDoai:cds.cern.ch:13766662011-08-23
spellingShingle Accelerators and Storage Rings
Calviani, M
Brugger, M
Spiezia, G
Sapinski, M
Priebe, A
Nordt, A
Pojer, M
R2E-related MD: slow controlled losses for RadMon/BLM cross-checks
title R2E-related MD: slow controlled losses for RadMon/BLM cross-checks
title_full R2E-related MD: slow controlled losses for RadMon/BLM cross-checks
title_fullStr R2E-related MD: slow controlled losses for RadMon/BLM cross-checks
title_full_unstemmed R2E-related MD: slow controlled losses for RadMon/BLM cross-checks
title_short R2E-related MD: slow controlled losses for RadMon/BLM cross-checks
title_sort r2e-related md: slow controlled losses for radmon/blm cross-checks
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/1376666
work_keys_str_mv AT calvianim r2erelatedmdslowcontrolledlossesforradmonblmcrosschecks
AT bruggerm r2erelatedmdslowcontrolledlossesforradmonblmcrosschecks
AT spieziag r2erelatedmdslowcontrolledlossesforradmonblmcrosschecks
AT sapinskim r2erelatedmdslowcontrolledlossesforradmonblmcrosschecks
AT priebea r2erelatedmdslowcontrolledlossesforradmonblmcrosschecks
AT nordta r2erelatedmdslowcontrolledlossesforradmonblmcrosschecks
AT pojerm r2erelatedmdslowcontrolledlossesforradmonblmcrosschecks