Beam-induced quench test of LHC main quadrupole
Unexpected beam loss might lead to a transition of the accelerator superconducting magnet to a normal conducting state. The LHC beam loss monitoring (BLM) system is designed to abort the beam before the energy deposited in the magnet coils reach a quench-provoking level. In order to verify the thres...
Autores principales: | Priebe, A, Dahlerup-Petersen, K, Dehning, B, Effinger, E, Emery, J, Holzer, E B, Kurfuerst, C, Nebot Del Busto, E, Nordt, A, Sapinski, M, Steckert, J, Verweij, A, Zamantzas, C |
---|---|
Lenguaje: | eng |
Publicado: |
2011
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1379458 |