Validation of a Micrometric remotely controlled pre-alignment system for the CLIC Linear Collider using a test setup (Mock-Up) with 5 degrees of freedom
The CLIC main beam quadrupoles need to be prealigned within 17 um rms with respect to a straight reference line along a sliding window of 200 m. A readjustment system based on eccentric cam movers, which will provide stiffness to the support assembly, is being studied. The cam movers were qualified...
Autores principales: | , , , , , |
---|---|
Formato: | info:eu-repo/semantics/article |
Lenguaje: | eng |
Publicado: |
2011
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1427722 |
_version_ | 1780924228791435264 |
---|---|
author | Mainaud Durand, H Anastasopoulos, M Griffet, S Kemppinen, J Leuxe, R Sosin, M |
author_facet | Mainaud Durand, H Anastasopoulos, M Griffet, S Kemppinen, J Leuxe, R Sosin, M |
author_sort | Mainaud Durand, H |
collection | CERN |
description | The CLIC main beam quadrupoles need to be prealigned within 17 um rms with respect to a straight reference line along a sliding window of 200 m. A readjustment system based on eccentric cam movers, which will provide stiffness to the support assembly, is being studied. The cam movers were qualified on a 1 degree of freedom (DOF) test setup, where a repeatability of adjustment below 1um was measured along their whole range. This paper presents the 5 DOF mock-up, built for the validation of the eccentric cam movers, as well as the first results of tests carried out: resolution of displacement along the whole range, measurements of the support eigenfrequencies. |
format | info:eu-repo/semantics/article |
id | cern-1380316 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2011 |
record_format | invenio |
spelling | cern-13803162023-07-20T15:01:52Z http://cds.cern.ch/record/1427722 eng Mainaud Durand, H Anastasopoulos, M Griffet, S Kemppinen, J Leuxe, R Sosin, M Validation of a Micrometric remotely controlled pre-alignment system for the CLIC Linear Collider using a test setup (Mock-Up) with 5 degrees of freedom Accelerators and Storage Rings 9: Technology for normal conducting higher energy linear accelerators The CLIC main beam quadrupoles need to be prealigned within 17 um rms with respect to a straight reference line along a sliding window of 200 m. A readjustment system based on eccentric cam movers, which will provide stiffness to the support assembly, is being studied. The cam movers were qualified on a 1 degree of freedom (DOF) test setup, where a repeatability of adjustment below 1um was measured along their whole range. This paper presents the 5 DOF mock-up, built for the validation of the eccentric cam movers, as well as the first results of tests carried out: resolution of displacement along the whole range, measurements of the support eigenfrequencies. info:eu-repo/grantAgreement/EC/FP7/227579 info:eu-repo/semantics/openAccess Education Level info:eu-repo/semantics/article http://cds.cern.ch/record/1427722 2011-09-07 |
spellingShingle | Accelerators and Storage Rings 9: Technology for normal conducting higher energy linear accelerators Mainaud Durand, H Anastasopoulos, M Griffet, S Kemppinen, J Leuxe, R Sosin, M Validation of a Micrometric remotely controlled pre-alignment system for the CLIC Linear Collider using a test setup (Mock-Up) with 5 degrees of freedom |
title | Validation of a Micrometric remotely controlled pre-alignment system for the CLIC Linear Collider using a test setup (Mock-Up) with 5 degrees of freedom |
title_full | Validation of a Micrometric remotely controlled pre-alignment system for the CLIC Linear Collider using a test setup (Mock-Up) with 5 degrees of freedom |
title_fullStr | Validation of a Micrometric remotely controlled pre-alignment system for the CLIC Linear Collider using a test setup (Mock-Up) with 5 degrees of freedom |
title_full_unstemmed | Validation of a Micrometric remotely controlled pre-alignment system for the CLIC Linear Collider using a test setup (Mock-Up) with 5 degrees of freedom |
title_short | Validation of a Micrometric remotely controlled pre-alignment system for the CLIC Linear Collider using a test setup (Mock-Up) with 5 degrees of freedom |
title_sort | validation of a micrometric remotely controlled pre-alignment system for the clic linear collider using a test setup (mock-up) with 5 degrees of freedom |
topic | Accelerators and Storage Rings 9: Technology for normal conducting higher energy linear accelerators |
url | http://cds.cern.ch/record/1427722 http://cds.cern.ch/record/1427722 |
work_keys_str_mv | AT mainauddurandh validationofamicrometricremotelycontrolledprealignmentsystemforthecliclinearcolliderusingatestsetupmockupwith5degreesoffreedom AT anastasopoulosm validationofamicrometricremotelycontrolledprealignmentsystemforthecliclinearcolliderusingatestsetupmockupwith5degreesoffreedom AT griffets validationofamicrometricremotelycontrolledprealignmentsystemforthecliclinearcolliderusingatestsetupmockupwith5degreesoffreedom AT kemppinenj validationofamicrometricremotelycontrolledprealignmentsystemforthecliclinearcolliderusingatestsetupmockupwith5degreesoffreedom AT leuxer validationofamicrometricremotelycontrolledprealignmentsystemforthecliclinearcolliderusingatestsetupmockupwith5degreesoffreedom AT sosinm validationofamicrometricremotelycontrolledprealignmentsystemforthecliclinearcolliderusingatestsetupmockupwith5degreesoffreedom |