Validation of a Micrometric remotely controlled pre-alignment system for the CLIC Linear Collider using a test setup (Mock-Up) with 5 degrees of freedom

The CLIC main beam quadrupoles need to be prealigned within 17 um rms with respect to a straight reference line along a sliding window of 200 m. A readjustment system based on eccentric cam movers, which will provide stiffness to the support assembly, is being studied. The cam movers were qualified...

Descripción completa

Detalles Bibliográficos
Autores principales: Mainaud Durand, H, Anastasopoulos, M, Griffet, S, Kemppinen, J, Leuxe, R, Sosin, M
Formato: info:eu-repo/semantics/article
Lenguaje:eng
Publicado: 2011
Materias:
Acceso en línea:http://cds.cern.ch/record/1427722
_version_ 1780924228791435264
author Mainaud Durand, H
Anastasopoulos, M
Griffet, S
Kemppinen, J
Leuxe, R
Sosin, M
author_facet Mainaud Durand, H
Anastasopoulos, M
Griffet, S
Kemppinen, J
Leuxe, R
Sosin, M
author_sort Mainaud Durand, H
collection CERN
description The CLIC main beam quadrupoles need to be prealigned within 17 um rms with respect to a straight reference line along a sliding window of 200 m. A readjustment system based on eccentric cam movers, which will provide stiffness to the support assembly, is being studied. The cam movers were qualified on a 1 degree of freedom (DOF) test setup, where a repeatability of adjustment below 1um was measured along their whole range. This paper presents the 5 DOF mock-up, built for the validation of the eccentric cam movers, as well as the first results of tests carried out: resolution of displacement along the whole range, measurements of the support eigenfrequencies.
format info:eu-repo/semantics/article
id cern-1380316
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2011
record_format invenio
spelling cern-13803162023-07-20T15:01:52Z http://cds.cern.ch/record/1427722 eng Mainaud Durand, H Anastasopoulos, M Griffet, S Kemppinen, J Leuxe, R Sosin, M Validation of a Micrometric remotely controlled pre-alignment system for the CLIC Linear Collider using a test setup (Mock-Up) with 5 degrees of freedom Accelerators and Storage Rings 9: Technology for normal conducting higher energy linear accelerators The CLIC main beam quadrupoles need to be prealigned within 17 um rms with respect to a straight reference line along a sliding window of 200 m. A readjustment system based on eccentric cam movers, which will provide stiffness to the support assembly, is being studied. The cam movers were qualified on a 1 degree of freedom (DOF) test setup, where a repeatability of adjustment below 1um was measured along their whole range. This paper presents the 5 DOF mock-up, built for the validation of the eccentric cam movers, as well as the first results of tests carried out: resolution of displacement along the whole range, measurements of the support eigenfrequencies. info:eu-repo/grantAgreement/EC/FP7/227579 info:eu-repo/semantics/openAccess Education Level info:eu-repo/semantics/article http://cds.cern.ch/record/1427722 2011-09-07
spellingShingle Accelerators and Storage Rings
9: Technology for normal conducting higher energy linear accelerators
Mainaud Durand, H
Anastasopoulos, M
Griffet, S
Kemppinen, J
Leuxe, R
Sosin, M
Validation of a Micrometric remotely controlled pre-alignment system for the CLIC Linear Collider using a test setup (Mock-Up) with 5 degrees of freedom
title Validation of a Micrometric remotely controlled pre-alignment system for the CLIC Linear Collider using a test setup (Mock-Up) with 5 degrees of freedom
title_full Validation of a Micrometric remotely controlled pre-alignment system for the CLIC Linear Collider using a test setup (Mock-Up) with 5 degrees of freedom
title_fullStr Validation of a Micrometric remotely controlled pre-alignment system for the CLIC Linear Collider using a test setup (Mock-Up) with 5 degrees of freedom
title_full_unstemmed Validation of a Micrometric remotely controlled pre-alignment system for the CLIC Linear Collider using a test setup (Mock-Up) with 5 degrees of freedom
title_short Validation of a Micrometric remotely controlled pre-alignment system for the CLIC Linear Collider using a test setup (Mock-Up) with 5 degrees of freedom
title_sort validation of a micrometric remotely controlled pre-alignment system for the clic linear collider using a test setup (mock-up) with 5 degrees of freedom
topic Accelerators and Storage Rings
9: Technology for normal conducting higher energy linear accelerators
url http://cds.cern.ch/record/1427722
http://cds.cern.ch/record/1427722
work_keys_str_mv AT mainauddurandh validationofamicrometricremotelycontrolledprealignmentsystemforthecliclinearcolliderusingatestsetupmockupwith5degreesoffreedom
AT anastasopoulosm validationofamicrometricremotelycontrolledprealignmentsystemforthecliclinearcolliderusingatestsetupmockupwith5degreesoffreedom
AT griffets validationofamicrometricremotelycontrolledprealignmentsystemforthecliclinearcolliderusingatestsetupmockupwith5degreesoffreedom
AT kemppinenj validationofamicrometricremotelycontrolledprealignmentsystemforthecliclinearcolliderusingatestsetupmockupwith5degreesoffreedom
AT leuxer validationofamicrometricremotelycontrolledprealignmentsystemforthecliclinearcolliderusingatestsetupmockupwith5degreesoffreedom
AT sosinm validationofamicrometricremotelycontrolledprealignmentsystemforthecliclinearcolliderusingatestsetupmockupwith5degreesoffreedom