Cargando…
Simulations of the impedance of the new PS wire scanner tank
The CERN Proton Synchrotron (PS) is equipped with 4 Fast Wire Scanners (FWS). It was identified that the small aperture of the current wire scanner tank causes beam losses and a new tank design was needed. The interaction of the PS bunches with the beam coupling impedance of this new tank may lead t...
Autores principales: | , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2011
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1381510 |
_version_ | 1780923090701647872 |
---|---|
author | Salvant, B Andreazza, W Caspers, F Grudiev, A Herranz Alvarez, J Métral, E Rumolo, G |
author_facet | Salvant, B Andreazza, W Caspers, F Grudiev, A Herranz Alvarez, J Métral, E Rumolo, G |
author_sort | Salvant, B |
collection | CERN |
description | The CERN Proton Synchrotron (PS) is equipped with 4 Fast Wire Scanners (FWS). It was identified that the small aperture of the current wire scanner tank causes beam losses and a new tank design was needed. The interaction of the PS bunches with the beam coupling impedance of this new tank may lead to beam degradation and wire damage. This contribution presents impedance studies of the current PS tank as well as the new design in order to assess the need to modify the design and/or install lossy materials plates dedicated to damp higher order cavity modes and reduce the total power deposited by the beam in the tank |
id | cern-1381510 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2011 |
record_format | invenio |
spelling | cern-13815102022-08-17T13:31:08Zhttp://cds.cern.ch/record/1381510engSalvant, BAndreazza, WCaspers, FGrudiev, AHerranz Alvarez, JMétral, ERumolo, GSimulations of the impedance of the new PS wire scanner tankAccelerators and Storage RingsThe CERN Proton Synchrotron (PS) is equipped with 4 Fast Wire Scanners (FWS). It was identified that the small aperture of the current wire scanner tank causes beam losses and a new tank design was needed. The interaction of the PS bunches with the beam coupling impedance of this new tank may lead to beam degradation and wire damage. This contribution presents impedance studies of the current PS tank as well as the new design in order to assess the need to modify the design and/or install lossy materials plates dedicated to damp higher order cavity modes and reduce the total power deposited by the beam in the tankCERN-ATS-2011-096oai:cds.cern.ch:13815102011-09-13 |
spellingShingle | Accelerators and Storage Rings Salvant, B Andreazza, W Caspers, F Grudiev, A Herranz Alvarez, J Métral, E Rumolo, G Simulations of the impedance of the new PS wire scanner tank |
title | Simulations of the impedance of the new PS wire scanner tank |
title_full | Simulations of the impedance of the new PS wire scanner tank |
title_fullStr | Simulations of the impedance of the new PS wire scanner tank |
title_full_unstemmed | Simulations of the impedance of the new PS wire scanner tank |
title_short | Simulations of the impedance of the new PS wire scanner tank |
title_sort | simulations of the impedance of the new ps wire scanner tank |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/1381510 |
work_keys_str_mv | AT salvantb simulationsoftheimpedanceofthenewpswirescannertank AT andreazzaw simulationsoftheimpedanceofthenewpswirescannertank AT caspersf simulationsoftheimpedanceofthenewpswirescannertank AT grudieva simulationsoftheimpedanceofthenewpswirescannertank AT herranzalvarezj simulationsoftheimpedanceofthenewpswirescannertank AT metrale simulationsoftheimpedanceofthenewpswirescannertank AT rumolog simulationsoftheimpedanceofthenewpswirescannertank |