Cargando…

Comparison of LHC collimation setups with manual and semi-automatic collimator alignment

The LHC collimation system beam-based alignment procedure has recently been upgraded to a semi-automatic process in order to increase its efficiency. In this paper, we describe the parameters used to measure the accuracy, stability and performance of the beam-based alignment of the LHC collimation s...

Descripción completa

Detalles Bibliográficos
Autores principales: Valentino, G, Assmann, R W, Bruce, R, Burkart, F, Cauchi, M, Deboy, D, Redaelli, S, Rossi, A, Sammut, N, Wollmann, D
Lenguaje:eng
Publicado: 2011
Materias:
Acceso en línea:http://cds.cern.ch/record/1381561
Descripción
Sumario:The LHC collimation system beam-based alignment procedure has recently been upgraded to a semi-automatic process in order to increase its efficiency. In this paper, we describe the parameters used to measure the accuracy, stability and performance of the beam-based alignment of the LHC collimation system. This is followed by a comparison of the results at 450 GeV and 3.5 TeV with (1) a manual alignment and (2) with the results for semi-automatic alignment.