Cargando…
Design of an on-line dynamic magnetic flux analyzer based on double-buffer sliding DFT
An on-line dynamic magnetic flux analyzer for magnetic measurement is presented. The instrument achieves on-line harmonic analysis by means of an improved implementation of the sliding DFT algorithm on the basis of the Fast Digital Integrator [1]. In particular, the round-off error, unacceptable in...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2011
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1385018 |
_version_ | 1780923188918616064 |
---|---|
author | Arpaia, P Fiscarelli, L Petrone, C Cardines, N |
author_facet | Arpaia, P Fiscarelli, L Petrone, C Cardines, N |
author_sort | Arpaia, P |
collection | CERN |
description | An on-line dynamic magnetic flux analyzer for magnetic measurement is presented. The instrument achieves on-line harmonic analysis by means of an improved implementation of the sliding DFT algorithm on the basis of the Fast Digital Integrator [1]. In particular, the round-off error, unacceptable in digital integrators, is corrected by employing two buffers alternatively. Details about the structure of the instrument and the algorithm implementation are pointed out, and some experimental results are analyzed in order to validate the proposal. |
id | cern-1385018 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2011 |
record_format | invenio |
spelling | cern-13850182019-09-30T06:29:59Zhttp://cds.cern.ch/record/1385018engArpaia, PFiscarelli, LPetrone, CCardines, NDesign of an on-line dynamic magnetic flux analyzer based on double-buffer sliding DFTAccelerators and Storage RingsAn on-line dynamic magnetic flux analyzer for magnetic measurement is presented. The instrument achieves on-line harmonic analysis by means of an improved implementation of the sliding DFT algorithm on the basis of the Fast Digital Integrator [1]. In particular, the round-off error, unacceptable in digital integrators, is corrected by employing two buffers alternatively. Details about the structure of the instrument and the algorithm implementation are pointed out, and some experimental results are analyzed in order to validate the proposal.CERN-ATS-2011-188oai:cds.cern.ch:13850182011-09-01 |
spellingShingle | Accelerators and Storage Rings Arpaia, P Fiscarelli, L Petrone, C Cardines, N Design of an on-line dynamic magnetic flux analyzer based on double-buffer sliding DFT |
title | Design of an on-line dynamic magnetic flux analyzer based on double-buffer sliding DFT |
title_full | Design of an on-line dynamic magnetic flux analyzer based on double-buffer sliding DFT |
title_fullStr | Design of an on-line dynamic magnetic flux analyzer based on double-buffer sliding DFT |
title_full_unstemmed | Design of an on-line dynamic magnetic flux analyzer based on double-buffer sliding DFT |
title_short | Design of an on-line dynamic magnetic flux analyzer based on double-buffer sliding DFT |
title_sort | design of an on-line dynamic magnetic flux analyzer based on double-buffer sliding dft |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/1385018 |
work_keys_str_mv | AT arpaiap designofanonlinedynamicmagneticfluxanalyzerbasedondoublebufferslidingdft AT fiscarellil designofanonlinedynamicmagneticfluxanalyzerbasedondoublebufferslidingdft AT petronec designofanonlinedynamicmagneticfluxanalyzerbasedondoublebufferslidingdft AT cardinesn designofanonlinedynamicmagneticfluxanalyzerbasedondoublebufferslidingdft |