Cargando…

Measurement of the CMS Magnetic Field

The measurement of the magnetic field in the tracking volume inside the superconducting coil of the Compact Muon Solenoid (CMS) detector under construction at CERN is done with a fieldmapper designed and produced at Fermilab. The fieldmapper uses 10 3-D B-sensors (Hall probes) developed at NIKHEF an...

Descripción completa

Detalles Bibliográficos
Autores principales: Klyukhin, V.I., Ball, A., Bergsma, F., Campi, D., Cure, B., Gaddi, A., Gerwig, H., Herve, A., Korienek, J., Linde, F., Lindenmeyer, C., Loveless, R., Mulders, M., Nebel, T., Smith, R.P., Stickland, D., Teafoe, G., Veillet, L., Zimmerman, J.K.
Lenguaje:eng
Publicado: 2011
Materias:
Acceso en línea:https://dx.doi.org/10.1109/TASC.2008.921242
http://cds.cern.ch/record/1387345
_version_ 1780923243483365376
author Klyukhin, V.I.
Ball, A.
Bergsma, F.
Campi, D.
Cure, B.
Gaddi, A.
Gerwig, H.
Herve, A.
Korienek, J.
Linde, F.
Lindenmeyer, C.
Loveless, R.
Mulders, M.
Nebel, T.
Smith, R.P.
Stickland, D.
Teafoe, G.
Veillet, L.
Zimmerman, J.K.
author_facet Klyukhin, V.I.
Ball, A.
Bergsma, F.
Campi, D.
Cure, B.
Gaddi, A.
Gerwig, H.
Herve, A.
Korienek, J.
Linde, F.
Lindenmeyer, C.
Loveless, R.
Mulders, M.
Nebel, T.
Smith, R.P.
Stickland, D.
Teafoe, G.
Veillet, L.
Zimmerman, J.K.
author_sort Klyukhin, V.I.
collection CERN
description The measurement of the magnetic field in the tracking volume inside the superconducting coil of the Compact Muon Solenoid (CMS) detector under construction at CERN is done with a fieldmapper designed and produced at Fermilab. The fieldmapper uses 10 3-D B-sensors (Hall probes) developed at NIKHEF and calibrated at CERN to precision 0.05% for a nominal 4 T field. The precise fieldmapper measurements are done in 33840 points inside a cylinder of 1.724 m radius and 7 m long at central fields of 2, 3, 3.5, 3.8, and 4 T. Three components of the magnetic flux density at the CMS coil maximum excitation and the remanent fields on the steel-air interface after discharge of the coil are measured in check-points with 95 3-D B-sensors located near the magnetic flux return yoke elements. Voltages induced in 22 flux-loops made of 405-turn installed on selected segments of the yoke are sampled online during the entire fast discharge (190 s time-constant) of the CMS coil and integrated offline to provide a measurement of the initial magnetic flux density in steel at the maximum field to an accuracy of a few percent. The results of the measurements made at 4 T are reported and compared with a three-dimensional model of the CMS magnet system calculated with TOSCA.
id cern-1387345
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2011
record_format invenio
spelling cern-13873452023-03-14T20:52:36Zdoi:10.1109/TASC.2008.921242http://cds.cern.ch/record/1387345engKlyukhin, V.I.Ball, A.Bergsma, F.Campi, D.Cure, B.Gaddi, A.Gerwig, H.Herve, A.Korienek, J.Linde, F.Lindenmeyer, C.Loveless, R.Mulders, M.Nebel, T.Smith, R.P.Stickland, D.Teafoe, G.Veillet, L.Zimmerman, J.K.Measurement of the CMS Magnetic FieldDetectors and Experimental TechniquesDetectors and Experimental TechniquesThe measurement of the magnetic field in the tracking volume inside the superconducting coil of the Compact Muon Solenoid (CMS) detector under construction at CERN is done with a fieldmapper designed and produced at Fermilab. The fieldmapper uses 10 3-D B-sensors (Hall probes) developed at NIKHEF and calibrated at CERN to precision 0.05% for a nominal 4 T field. The precise fieldmapper measurements are done in 33840 points inside a cylinder of 1.724 m radius and 7 m long at central fields of 2, 3, 3.5, 3.8, and 4 T. Three components of the magnetic flux density at the CMS coil maximum excitation and the remanent fields on the steel-air interface after discharge of the coil are measured in check-points with 95 3-D B-sensors located near the magnetic flux return yoke elements. Voltages induced in 22 flux-loops made of 405-turn installed on selected segments of the yoke are sampled online during the entire fast discharge (190 s time-constant) of the CMS coil and integrated offline to provide a measurement of the initial magnetic flux density in steel at the maximum field to an accuracy of a few percent. The results of the measurements made at 4 T are reported and compared with a three-dimensional model of the CMS magnet system calculated with TOSCA.The measurement of the magnetic field in the tracking volume inside the superconducting coil of the Compact Muon Solenoid (CMS) detector under construction at CERN is done with a fieldmapper designed and produced at Fermilab. The fieldmapper uses 10 3-D B-sensors (Hall probes) developed at NIKHEF and calibrated at CERN to precision 0.05% for a nominal 4 T field. The precise fieldmapper measurements are done in 33840 points inside a cylinder of 1.724 m radius and 7 m long at central fields of 2, 3, 3.5, 3.8, and 4 T. Three components of the magnetic flux density at the CMS coil maximum excitation and the remanent fields on the steel-air interface after discharge of the coil are measured in check-points with 95 3-D B-sensors located near the magnetic flux return yoke elements. Voltages induced in 22 flux-loops made of 405-turn installed on selected segments of the yoke are sampled online during the entire fast discharge (190 s time-constant) of the CMS coil and integrated offline to provide a measurement of the initial magnetic flux density in steel at the maximum field to an accuracy of a few percent. The results of the measurements made at 4 T are reported and compared with a three-dimensional model of the CMS magnet system calculated with TOSCA.arXiv:1110.0306oai:cds.cern.ch:13873452011-10-04
spellingShingle Detectors and Experimental Techniques
Detectors and Experimental Techniques
Klyukhin, V.I.
Ball, A.
Bergsma, F.
Campi, D.
Cure, B.
Gaddi, A.
Gerwig, H.
Herve, A.
Korienek, J.
Linde, F.
Lindenmeyer, C.
Loveless, R.
Mulders, M.
Nebel, T.
Smith, R.P.
Stickland, D.
Teafoe, G.
Veillet, L.
Zimmerman, J.K.
Measurement of the CMS Magnetic Field
title Measurement of the CMS Magnetic Field
title_full Measurement of the CMS Magnetic Field
title_fullStr Measurement of the CMS Magnetic Field
title_full_unstemmed Measurement of the CMS Magnetic Field
title_short Measurement of the CMS Magnetic Field
title_sort measurement of the cms magnetic field
topic Detectors and Experimental Techniques
Detectors and Experimental Techniques
url https://dx.doi.org/10.1109/TASC.2008.921242
http://cds.cern.ch/record/1387345
work_keys_str_mv AT klyukhinvi measurementofthecmsmagneticfield
AT balla measurementofthecmsmagneticfield
AT bergsmaf measurementofthecmsmagneticfield
AT campid measurementofthecmsmagneticfield
AT cureb measurementofthecmsmagneticfield
AT gaddia measurementofthecmsmagneticfield
AT gerwigh measurementofthecmsmagneticfield
AT hervea measurementofthecmsmagneticfield
AT korienekj measurementofthecmsmagneticfield
AT lindef measurementofthecmsmagneticfield
AT lindenmeyerc measurementofthecmsmagneticfield
AT lovelessr measurementofthecmsmagneticfield
AT muldersm measurementofthecmsmagneticfield
AT nebelt measurementofthecmsmagneticfield
AT smithrp measurementofthecmsmagneticfield
AT sticklandd measurementofthecmsmagneticfield
AT teafoeg measurementofthecmsmagneticfield
AT veilletl measurementofthecmsmagneticfield
AT zimmermanjk measurementofthecmsmagneticfield