COLDDIAG: A Cold Vacuum Chamber for Diagnostics

One of the still open issues for the development of superconducting insertion devices is the understanding of the beam heat load. With the aim of measuring the beam heat load to a cold bore and the hope to gain a deeper understanding in the beam heat load mechanisms, a cold vacuum chamber for diagno...

Descripción completa

Detalles Bibliográficos
Autores principales: Casalbuoni, S, Baumbach, T, Gerstl, S, Grau, A W, Hagelstein, M, Saez de Jauregui, D, Boffo, C, Sikler, G, Baglin, V, Cox, M P, Schouten, J C, Cimino, R, Commisso, M, Spataro, B, Mostacci, A, Wallen, E J, Weigel, R, Clarke, J, Scott, D, Bradshaw, T, Jones, R, Shinton, I
Lenguaje:eng
Publicado: 2011
Materias:
Acceso en línea:https://dx.doi.org/10.1109/TASC.2010.2096176
http://cds.cern.ch/record/1398232
_version_ 1780923552818528256
author Casalbuoni, S
Baumbach, T
Gerstl, S
Grau, A W
Hagelstein, M
Saez de Jauregui, D
Boffo, C
Sikler, G
Baglin, V
Cox, M P
Schouten, J C
Cimino, R
Commisso, M
Spataro, B
Mostacci, A
Wallen, E J
Weigel, R
Clarke, J
Scott, D
Bradshaw, T
Jones, R
Shinton, I
author_facet Casalbuoni, S
Baumbach, T
Gerstl, S
Grau, A W
Hagelstein, M
Saez de Jauregui, D
Boffo, C
Sikler, G
Baglin, V
Cox, M P
Schouten, J C
Cimino, R
Commisso, M
Spataro, B
Mostacci, A
Wallen, E J
Weigel, R
Clarke, J
Scott, D
Bradshaw, T
Jones, R
Shinton, I
author_sort Casalbuoni, S
collection CERN
description One of the still open issues for the development of superconducting insertion devices is the understanding of the beam heat load. With the aim of measuring the beam heat load to a cold bore and the hope to gain a deeper understanding in the beam heat load mechanisms, a cold vacuum chamber for diagnostics is under construction. The following diagnostics will be implemented: i) retarding field analyzers to measure the electron energy and flux, ii) temperature sensors to measure the total heat load, iii) pressure gauges, iv) and mass spectrometers to measure the gas content. The inner vacuum chamber will be removable in order to test different geometries and materials. This will allow the installation of the cryostat in different synchrotron light sources. COLDDIAG will be built to fit in a short straight section at ANKA. A first installation at the synchrotron light source Diamond is foreseen in June 2011. Here we describe the technical design report of this device and the planned measurements with beam.
id cern-1398232
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2011
record_format invenio
spelling cern-13982322019-09-30T06:29:59Zdoi:10.1109/TASC.2010.2096176http://cds.cern.ch/record/1398232engCasalbuoni, SBaumbach, TGerstl, SGrau, A WHagelstein, MSaez de Jauregui, DBoffo, CSikler, GBaglin, VCox, M PSchouten, J CCimino, RCommisso, MSpataro, BMostacci, AWallen, E JWeigel, RClarke, JScott, DBradshaw, TJones, RShinton, ICOLDDIAG: A Cold Vacuum Chamber for Diagnostics Accelerators and Storage RingsOne of the still open issues for the development of superconducting insertion devices is the understanding of the beam heat load. With the aim of measuring the beam heat load to a cold bore and the hope to gain a deeper understanding in the beam heat load mechanisms, a cold vacuum chamber for diagnostics is under construction. The following diagnostics will be implemented: i) retarding field analyzers to measure the electron energy and flux, ii) temperature sensors to measure the total heat load, iii) pressure gauges, iv) and mass spectrometers to measure the gas content. The inner vacuum chamber will be removable in order to test different geometries and materials. This will allow the installation of the cryostat in different synchrotron light sources. COLDDIAG will be built to fit in a short straight section at ANKA. A first installation at the synchrotron light source Diamond is foreseen in June 2011. Here we describe the technical design report of this device and the planned measurements with beam.oai:cds.cern.ch:13982322011
spellingShingle Accelerators and Storage Rings
Casalbuoni, S
Baumbach, T
Gerstl, S
Grau, A W
Hagelstein, M
Saez de Jauregui, D
Boffo, C
Sikler, G
Baglin, V
Cox, M P
Schouten, J C
Cimino, R
Commisso, M
Spataro, B
Mostacci, A
Wallen, E J
Weigel, R
Clarke, J
Scott, D
Bradshaw, T
Jones, R
Shinton, I
COLDDIAG: A Cold Vacuum Chamber for Diagnostics
title COLDDIAG: A Cold Vacuum Chamber for Diagnostics
title_full COLDDIAG: A Cold Vacuum Chamber for Diagnostics
title_fullStr COLDDIAG: A Cold Vacuum Chamber for Diagnostics
title_full_unstemmed COLDDIAG: A Cold Vacuum Chamber for Diagnostics
title_short COLDDIAG: A Cold Vacuum Chamber for Diagnostics
title_sort colddiag: a cold vacuum chamber for diagnostics
topic Accelerators and Storage Rings
url https://dx.doi.org/10.1109/TASC.2010.2096176
http://cds.cern.ch/record/1398232
work_keys_str_mv AT casalbuonis colddiagacoldvacuumchamberfordiagnostics
AT baumbacht colddiagacoldvacuumchamberfordiagnostics
AT gerstls colddiagacoldvacuumchamberfordiagnostics
AT grauaw colddiagacoldvacuumchamberfordiagnostics
AT hagelsteinm colddiagacoldvacuumchamberfordiagnostics
AT saezdejaureguid colddiagacoldvacuumchamberfordiagnostics
AT boffoc colddiagacoldvacuumchamberfordiagnostics
AT siklerg colddiagacoldvacuumchamberfordiagnostics
AT baglinv colddiagacoldvacuumchamberfordiagnostics
AT coxmp colddiagacoldvacuumchamberfordiagnostics
AT schoutenjc colddiagacoldvacuumchamberfordiagnostics
AT ciminor colddiagacoldvacuumchamberfordiagnostics
AT commissom colddiagacoldvacuumchamberfordiagnostics
AT spatarob colddiagacoldvacuumchamberfordiagnostics
AT mostaccia colddiagacoldvacuumchamberfordiagnostics
AT wallenej colddiagacoldvacuumchamberfordiagnostics
AT weigelr colddiagacoldvacuumchamberfordiagnostics
AT clarkej colddiagacoldvacuumchamberfordiagnostics
AT scottd colddiagacoldvacuumchamberfordiagnostics
AT bradshawt colddiagacoldvacuumchamberfordiagnostics
AT jonesr colddiagacoldvacuumchamberfordiagnostics
AT shintoni colddiagacoldvacuumchamberfordiagnostics