Cargando…
A Transparent Detector for n_TOF Neutron Beam Monitoring
In order to obtain high precision cross-section measurements using the time-of-flight technique, it is important to know with good accuracy the neutron fluence at the measuring station. The detector dedicated to these measurements should be placed upstream of the detectors used for capture and fissi...
Autores principales: | , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2011
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.3938/jkps.59.1597 http://cds.cern.ch/record/1399700 |
_version_ | 1780923610344456192 |
---|---|
author | Andriamonje, S Giomataris, Y Vlachoudis, V Guerrero, C Schillebeeckx, P Losito, R Sarmento, R Calviani, M Giganon, A Gunsing, F Berthoumieux, E Siegler, P Kadi, Y |
author_facet | Andriamonje, S Giomataris, Y Vlachoudis, V Guerrero, C Schillebeeckx, P Losito, R Sarmento, R Calviani, M Giganon, A Gunsing, F Berthoumieux, E Siegler, P Kadi, Y |
author_sort | Andriamonje, S |
collection | CERN |
description | In order to obtain high precision cross-section measurements using the time-of-flight technique, it is important to know with good accuracy the neutron fluence at the measuring station. The detector dedicated to these measurements should be placed upstream of the detectors used for capture and fission cross-section measurements. The main requirement is to reduce the material of the detector as much as possible, in order to minimize the perturbation of the neutron beam and, especially, the background produced by the device itself. According to these considerations, a new neutron detector equipped with a small-mass device based on MicroMegas ``Micro-bulk{''} technology has been developed as a monitoring detector for the CERN n\_TOF neutron beam. A description of the different characteristics of tins innovative concept of transparent detector for neutron beam monitoring is presented. The result obtained in the commissioning of the new spallation target of the n\_TOF facility at CERN is shown, compared with simulations performed with the FLUKA code. |
id | cern-1399700 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2011 |
record_format | invenio |
spelling | cern-13997002019-09-30T06:29:59Zdoi:10.3938/jkps.59.1597http://cds.cern.ch/record/1399700engAndriamonje, SGiomataris, YVlachoudis, VGuerrero, CSchillebeeckx, PLosito, RSarmento, RCalviani, MGiganon, AGunsing, FBerthoumieux, ESiegler, PKadi, YA Transparent Detector for n_TOF Neutron Beam MonitoringXXIn order to obtain high precision cross-section measurements using the time-of-flight technique, it is important to know with good accuracy the neutron fluence at the measuring station. The detector dedicated to these measurements should be placed upstream of the detectors used for capture and fission cross-section measurements. The main requirement is to reduce the material of the detector as much as possible, in order to minimize the perturbation of the neutron beam and, especially, the background produced by the device itself. According to these considerations, a new neutron detector equipped with a small-mass device based on MicroMegas ``Micro-bulk{''} technology has been developed as a monitoring detector for the CERN n\_TOF neutron beam. A description of the different characteristics of tins innovative concept of transparent detector for neutron beam monitoring is presented. The result obtained in the commissioning of the new spallation target of the n\_TOF facility at CERN is shown, compared with simulations performed with the FLUKA code.oai:cds.cern.ch:13997002011 |
spellingShingle | XX Andriamonje, S Giomataris, Y Vlachoudis, V Guerrero, C Schillebeeckx, P Losito, R Sarmento, R Calviani, M Giganon, A Gunsing, F Berthoumieux, E Siegler, P Kadi, Y A Transparent Detector for n_TOF Neutron Beam Monitoring |
title | A Transparent Detector for n_TOF Neutron Beam Monitoring |
title_full | A Transparent Detector for n_TOF Neutron Beam Monitoring |
title_fullStr | A Transparent Detector for n_TOF Neutron Beam Monitoring |
title_full_unstemmed | A Transparent Detector for n_TOF Neutron Beam Monitoring |
title_short | A Transparent Detector for n_TOF Neutron Beam Monitoring |
title_sort | transparent detector for n_tof neutron beam monitoring |
topic | XX |
url | https://dx.doi.org/10.3938/jkps.59.1597 http://cds.cern.ch/record/1399700 |
work_keys_str_mv | AT andriamonjes atransparentdetectorforntofneutronbeammonitoring AT giomatarisy atransparentdetectorforntofneutronbeammonitoring AT vlachoudisv atransparentdetectorforntofneutronbeammonitoring AT guerreroc atransparentdetectorforntofneutronbeammonitoring AT schillebeeckxp atransparentdetectorforntofneutronbeammonitoring AT lositor atransparentdetectorforntofneutronbeammonitoring AT sarmentor atransparentdetectorforntofneutronbeammonitoring AT calvianim atransparentdetectorforntofneutronbeammonitoring AT giganona atransparentdetectorforntofneutronbeammonitoring AT gunsingf atransparentdetectorforntofneutronbeammonitoring AT berthoumieuxe atransparentdetectorforntofneutronbeammonitoring AT sieglerp atransparentdetectorforntofneutronbeammonitoring AT kadiy atransparentdetectorforntofneutronbeammonitoring AT andriamonjes transparentdetectorforntofneutronbeammonitoring AT giomatarisy transparentdetectorforntofneutronbeammonitoring AT vlachoudisv transparentdetectorforntofneutronbeammonitoring AT guerreroc transparentdetectorforntofneutronbeammonitoring AT schillebeeckxp transparentdetectorforntofneutronbeammonitoring AT lositor transparentdetectorforntofneutronbeammonitoring AT sarmentor transparentdetectorforntofneutronbeammonitoring AT calvianim transparentdetectorforntofneutronbeammonitoring AT giganona transparentdetectorforntofneutronbeammonitoring AT gunsingf transparentdetectorforntofneutronbeammonitoring AT berthoumieuxe transparentdetectorforntofneutronbeammonitoring AT sieglerp transparentdetectorforntofneutronbeammonitoring AT kadiy transparentdetectorforntofneutronbeammonitoring |