Cargando…

A Transparent Detector for n_TOF Neutron Beam Monitoring

In order to obtain high precision cross-section measurements using the time-of-flight technique, it is important to know with good accuracy the neutron fluence at the measuring station. The detector dedicated to these measurements should be placed upstream of the detectors used for capture and fissi...

Descripción completa

Detalles Bibliográficos
Autores principales: Andriamonje, S, Giomataris, Y, Vlachoudis, V, Guerrero, C, Schillebeeckx, P, Losito, R, Sarmento, R, Calviani, M, Giganon, A, Gunsing, F, Berthoumieux, E, Siegler, P, Kadi, Y
Lenguaje:eng
Publicado: 2011
Materias:
XX
Acceso en línea:https://dx.doi.org/10.3938/jkps.59.1597
http://cds.cern.ch/record/1399700
_version_ 1780923610344456192
author Andriamonje, S
Giomataris, Y
Vlachoudis, V
Guerrero, C
Schillebeeckx, P
Losito, R
Sarmento, R
Calviani, M
Giganon, A
Gunsing, F
Berthoumieux, E
Siegler, P
Kadi, Y
author_facet Andriamonje, S
Giomataris, Y
Vlachoudis, V
Guerrero, C
Schillebeeckx, P
Losito, R
Sarmento, R
Calviani, M
Giganon, A
Gunsing, F
Berthoumieux, E
Siegler, P
Kadi, Y
author_sort Andriamonje, S
collection CERN
description In order to obtain high precision cross-section measurements using the time-of-flight technique, it is important to know with good accuracy the neutron fluence at the measuring station. The detector dedicated to these measurements should be placed upstream of the detectors used for capture and fission cross-section measurements. The main requirement is to reduce the material of the detector as much as possible, in order to minimize the perturbation of the neutron beam and, especially, the background produced by the device itself. According to these considerations, a new neutron detector equipped with a small-mass device based on MicroMegas ``Micro-bulk{''} technology has been developed as a monitoring detector for the CERN n\_TOF neutron beam. A description of the different characteristics of tins innovative concept of transparent detector for neutron beam monitoring is presented. The result obtained in the commissioning of the new spallation target of the n\_TOF facility at CERN is shown, compared with simulations performed with the FLUKA code.
id cern-1399700
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2011
record_format invenio
spelling cern-13997002019-09-30T06:29:59Zdoi:10.3938/jkps.59.1597http://cds.cern.ch/record/1399700engAndriamonje, SGiomataris, YVlachoudis, VGuerrero, CSchillebeeckx, PLosito, RSarmento, RCalviani, MGiganon, AGunsing, FBerthoumieux, ESiegler, PKadi, YA Transparent Detector for n_TOF Neutron Beam MonitoringXXIn order to obtain high precision cross-section measurements using the time-of-flight technique, it is important to know with good accuracy the neutron fluence at the measuring station. The detector dedicated to these measurements should be placed upstream of the detectors used for capture and fission cross-section measurements. The main requirement is to reduce the material of the detector as much as possible, in order to minimize the perturbation of the neutron beam and, especially, the background produced by the device itself. According to these considerations, a new neutron detector equipped with a small-mass device based on MicroMegas ``Micro-bulk{''} technology has been developed as a monitoring detector for the CERN n\_TOF neutron beam. A description of the different characteristics of tins innovative concept of transparent detector for neutron beam monitoring is presented. The result obtained in the commissioning of the new spallation target of the n\_TOF facility at CERN is shown, compared with simulations performed with the FLUKA code.oai:cds.cern.ch:13997002011
spellingShingle XX
Andriamonje, S
Giomataris, Y
Vlachoudis, V
Guerrero, C
Schillebeeckx, P
Losito, R
Sarmento, R
Calviani, M
Giganon, A
Gunsing, F
Berthoumieux, E
Siegler, P
Kadi, Y
A Transparent Detector for n_TOF Neutron Beam Monitoring
title A Transparent Detector for n_TOF Neutron Beam Monitoring
title_full A Transparent Detector for n_TOF Neutron Beam Monitoring
title_fullStr A Transparent Detector for n_TOF Neutron Beam Monitoring
title_full_unstemmed A Transparent Detector for n_TOF Neutron Beam Monitoring
title_short A Transparent Detector for n_TOF Neutron Beam Monitoring
title_sort transparent detector for n_tof neutron beam monitoring
topic XX
url https://dx.doi.org/10.3938/jkps.59.1597
http://cds.cern.ch/record/1399700
work_keys_str_mv AT andriamonjes atransparentdetectorforntofneutronbeammonitoring
AT giomatarisy atransparentdetectorforntofneutronbeammonitoring
AT vlachoudisv atransparentdetectorforntofneutronbeammonitoring
AT guerreroc atransparentdetectorforntofneutronbeammonitoring
AT schillebeeckxp atransparentdetectorforntofneutronbeammonitoring
AT lositor atransparentdetectorforntofneutronbeammonitoring
AT sarmentor atransparentdetectorforntofneutronbeammonitoring
AT calvianim atransparentdetectorforntofneutronbeammonitoring
AT giganona atransparentdetectorforntofneutronbeammonitoring
AT gunsingf atransparentdetectorforntofneutronbeammonitoring
AT berthoumieuxe atransparentdetectorforntofneutronbeammonitoring
AT sieglerp atransparentdetectorforntofneutronbeammonitoring
AT kadiy atransparentdetectorforntofneutronbeammonitoring
AT andriamonjes transparentdetectorforntofneutronbeammonitoring
AT giomatarisy transparentdetectorforntofneutronbeammonitoring
AT vlachoudisv transparentdetectorforntofneutronbeammonitoring
AT guerreroc transparentdetectorforntofneutronbeammonitoring
AT schillebeeckxp transparentdetectorforntofneutronbeammonitoring
AT lositor transparentdetectorforntofneutronbeammonitoring
AT sarmentor transparentdetectorforntofneutronbeammonitoring
AT calvianim transparentdetectorforntofneutronbeammonitoring
AT giganona transparentdetectorforntofneutronbeammonitoring
AT gunsingf transparentdetectorforntofneutronbeammonitoring
AT berthoumieuxe transparentdetectorforntofneutronbeammonitoring
AT sieglerp transparentdetectorforntofneutronbeammonitoring
AT kadiy transparentdetectorforntofneutronbeammonitoring