Pixel sensitivity variations in a CdTe-Medipix2 detector using poly-energetic x-rays

We have a 1-mm-thick cadmium telluride (CdTe) sensor bump-bonded to a Medipix2 readout chip. This detector has been characterized using a poly-energetic x-ray beam. Open beam images (i.e. without an attenuating specimen between the x-ray source and the detector) have been acquired at room temperatur...

Descripción completa

Detalles Bibliográficos
Autores principales: Aamir, R, Butler, P H, Greiffenberg, D, Lansley, S P, Butler, A P H, Zainon, R, Fauler, A, Fiederle, M
Lenguaje:eng
Publicado: 2011
Materias:
Acceso en línea:https://dx.doi.org/10.1088/1748-0221/6/01/C01059
http://cds.cern.ch/record/1399883
_version_ 1780923642436124672
author Aamir, R
Butler, P H
Greiffenberg, D
Lansley, S P
Butler, A P H
Zainon, R
Fauler, A
Fiederle, M
author_facet Aamir, R
Butler, P H
Greiffenberg, D
Lansley, S P
Butler, A P H
Zainon, R
Fauler, A
Fiederle, M
author_sort Aamir, R
collection CERN
description We have a 1-mm-thick cadmium telluride (CdTe) sensor bump-bonded to a Medipix2 readout chip. This detector has been characterized using a poly-energetic x-ray beam. Open beam images (i.e. without an attenuating specimen between the x-ray source and the detector) have been acquired at room temperature using the MARS-CT system. Profiles of various rows and columns were analyzed for one hundred, 35-ms exposures taken with a bias voltage of -300 V (operating in electron collection mode). A region of increased sensitivity is observed around the edges of the detector. A reasonably periodic, repeatable variation in pixel sensitivity is observed. Some small regions with very low sensitivity and others with zero signals are also observed. Surrounding these regions are circular rings of pixels with higher counts. At higher flux (higher tube current in the x-ray source) there is evidence of saturation of the detector assembly. In this paper we present our understanding of the origin of these features and demonstrate the improved image quality obtained after correcting for these variations.
id cern-1399883
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2011
record_format invenio
spelling cern-13998832019-09-30T06:29:59Zdoi:10.1088/1748-0221/6/01/C01059http://cds.cern.ch/record/1399883engAamir, RButler, P HGreiffenberg, DLansley, S PButler, A P HZainon, RFauler, AFiederle, MPixel sensitivity variations in a CdTe-Medipix2 detector using poly-energetic x-raysDetectors and Experimental TechniquesWe have a 1-mm-thick cadmium telluride (CdTe) sensor bump-bonded to a Medipix2 readout chip. This detector has been characterized using a poly-energetic x-ray beam. Open beam images (i.e. without an attenuating specimen between the x-ray source and the detector) have been acquired at room temperature using the MARS-CT system. Profiles of various rows and columns were analyzed for one hundred, 35-ms exposures taken with a bias voltage of -300 V (operating in electron collection mode). A region of increased sensitivity is observed around the edges of the detector. A reasonably periodic, repeatable variation in pixel sensitivity is observed. Some small regions with very low sensitivity and others with zero signals are also observed. Surrounding these regions are circular rings of pixels with higher counts. At higher flux (higher tube current in the x-ray source) there is evidence of saturation of the detector assembly. In this paper we present our understanding of the origin of these features and demonstrate the improved image quality obtained after correcting for these variations.oai:cds.cern.ch:13998832011
spellingShingle Detectors and Experimental Techniques
Aamir, R
Butler, P H
Greiffenberg, D
Lansley, S P
Butler, A P H
Zainon, R
Fauler, A
Fiederle, M
Pixel sensitivity variations in a CdTe-Medipix2 detector using poly-energetic x-rays
title Pixel sensitivity variations in a CdTe-Medipix2 detector using poly-energetic x-rays
title_full Pixel sensitivity variations in a CdTe-Medipix2 detector using poly-energetic x-rays
title_fullStr Pixel sensitivity variations in a CdTe-Medipix2 detector using poly-energetic x-rays
title_full_unstemmed Pixel sensitivity variations in a CdTe-Medipix2 detector using poly-energetic x-rays
title_short Pixel sensitivity variations in a CdTe-Medipix2 detector using poly-energetic x-rays
title_sort pixel sensitivity variations in a cdte-medipix2 detector using poly-energetic x-rays
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1088/1748-0221/6/01/C01059
http://cds.cern.ch/record/1399883
work_keys_str_mv AT aamirr pixelsensitivityvariationsinacdtemedipix2detectorusingpolyenergeticxrays
AT butlerph pixelsensitivityvariationsinacdtemedipix2detectorusingpolyenergeticxrays
AT greiffenbergd pixelsensitivityvariationsinacdtemedipix2detectorusingpolyenergeticxrays
AT lansleysp pixelsensitivityvariationsinacdtemedipix2detectorusingpolyenergeticxrays
AT butleraph pixelsensitivityvariationsinacdtemedipix2detectorusingpolyenergeticxrays
AT zainonr pixelsensitivityvariationsinacdtemedipix2detectorusingpolyenergeticxrays
AT faulera pixelsensitivityvariationsinacdtemedipix2detectorusingpolyenergeticxrays
AT fiederlem pixelsensitivityvariationsinacdtemedipix2detectorusingpolyenergeticxrays