Cargando…

CALIBRATION ERRORS IN THE CAVITY BEAM POSITION MONITOR SYSTEM AT THE ATF2

It has been shown at the Accelerator Test Facility at KEK, that it is possible to run a system of 37 cavity beam position monitors (BPMs) and achieve high working resolution. However, stability of the calibration constants (position scale and radio frequency (RF) phase) over a three/four week runnin...

Descripción completa

Detalles Bibliográficos
Autores principales: Cullinan, F, Boogert, S T, Joshi, N, Lyapin, A
Formato: info:eu-repo/semantics/article
Lenguaje:eng
Publicado: 2011
Materias:
Acceso en línea:http://cds.cern.ch/record/1403143
_version_ 1780923718607831040
author Cullinan, F
Boogert, S T
Joshi, N
Lyapin, A
author_facet Cullinan, F
Boogert, S T
Joshi, N
Lyapin, A
author_sort Cullinan, F
collection CERN
description It has been shown at the Accelerator Test Facility at KEK, that it is possible to run a system of 37 cavity beam position monitors (BPMs) and achieve high working resolution. However, stability of the calibration constants (position scale and radio frequency (RF) phase) over a three/four week running period is yet to be demonstrated. During the calibration procedure, random beam jitter gives rise to a statistical error in the position scale and slow orbit drift in position and tilt causes systematic errors in both the position scale and RF phase. These errors are dominant and have been evaluated for each BPM. The results are compared with the errors expected after a tested method of beam jitter subtraction has been applied.
format info:eu-repo/semantics/article
id cern-1403143
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2011
record_format invenio
spelling cern-14031432019-09-30T06:29:59Z http://cds.cern.ch/record/1403143 eng Cullinan, F Boogert, S T Joshi, N Lyapin, A CALIBRATION ERRORS IN THE CAVITY BEAM POSITION MONITOR SYSTEM AT THE ATF2 Accelerators and Storage Rings 9: Technology for normal conducting higher energy linear accelerators It has been shown at the Accelerator Test Facility at KEK, that it is possible to run a system of 37 cavity beam position monitors (BPMs) and achieve high working resolution. However, stability of the calibration constants (position scale and radio frequency (RF) phase) over a three/four week running period is yet to be demonstrated. During the calibration procedure, random beam jitter gives rise to a statistical error in the position scale and slow orbit drift in position and tilt causes systematic errors in both the position scale and RF phase. These errors are dominant and have been evaluated for each BPM. The results are compared with the errors expected after a tested method of beam jitter subtraction has been applied. info:eu-repo/grantAgreement/EC/FP7/227579 info:eu-repo/semantics/openAccess Education Level info:eu-repo/semantics/article http://cds.cern.ch/record/1403143 2011
spellingShingle Accelerators and Storage Rings
9: Technology for normal conducting higher energy linear accelerators
Cullinan, F
Boogert, S T
Joshi, N
Lyapin, A
CALIBRATION ERRORS IN THE CAVITY BEAM POSITION MONITOR SYSTEM AT THE ATF2
title CALIBRATION ERRORS IN THE CAVITY BEAM POSITION MONITOR SYSTEM AT THE ATF2
title_full CALIBRATION ERRORS IN THE CAVITY BEAM POSITION MONITOR SYSTEM AT THE ATF2
title_fullStr CALIBRATION ERRORS IN THE CAVITY BEAM POSITION MONITOR SYSTEM AT THE ATF2
title_full_unstemmed CALIBRATION ERRORS IN THE CAVITY BEAM POSITION MONITOR SYSTEM AT THE ATF2
title_short CALIBRATION ERRORS IN THE CAVITY BEAM POSITION MONITOR SYSTEM AT THE ATF2
title_sort calibration errors in the cavity beam position monitor system at the atf2
topic Accelerators and Storage Rings
9: Technology for normal conducting higher energy linear accelerators
url http://cds.cern.ch/record/1403143
http://cds.cern.ch/record/1403143
work_keys_str_mv AT cullinanf calibrationerrorsinthecavitybeampositionmonitorsystemattheatf2
AT boogertst calibrationerrorsinthecavitybeampositionmonitorsystemattheatf2
AT joshin calibrationerrorsinthecavitybeampositionmonitorsystemattheatf2
AT lyapina calibrationerrorsinthecavitybeampositionmonitorsystemattheatf2