Cargando…
Status of a study of stabilization and fine positioning of CLIC quadrupoles to the nanometre level
Mechanical stability to the nanometre and below is required for the Compact Linear Collider (CLIC) quadrupoles to frequencies as low as 1 Hz. An active stabilization and positioning system based on very stiff piezo electric actuators and inertial reference masses is under study for the Main Beam Qua...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | info:eu-repo/semantics/article |
Lenguaje: | eng |
Publicado: |
2011
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1423005 |
_version_ | 1780924125529767936 |
---|---|
author | Artoos, K Collette, C Esposito, M Fernandez Carmona, P Guinchard, M Hauviller, C Janssens, S Kuzmin, A Leuxe, R Moron Ballester, R |
author_facet | Artoos, K Collette, C Esposito, M Fernandez Carmona, P Guinchard, M Hauviller, C Janssens, S Kuzmin, A Leuxe, R Moron Ballester, R |
author_sort | Artoos, K |
collection | CERN |
description | Mechanical stability to the nanometre and below is required for the Compact Linear Collider (CLIC) quadrupoles to frequencies as low as 1 Hz. An active stabilization and positioning system based on very stiff piezo electric actuators and inertial reference masses is under study for the Main Beam Quadrupoles (MBQ). The stiff support was selected for robustness against direct forces and for the option of incrementally repositioning the magnet with nanometre resolution. The technical feasibility was demonstrated by a representative test mass being stabilized and repositioned to the required level in the vertical and lateral direction. Technical issues were identified and the development programme of the support, sensors, and controller was continued to increase the performance, integrate the system in the overall controller, adapt to the accelerator environment, and reduce costs. The improvements are implemented in models, test benches, and design of the first stabilized prototype CLIC magnet. The characterization of vibration sources was extended to forces acting directly on the magnet, such as water-cooling induced vibrations. This paper shows the achievements, improvements, and an outlook on further R&D. |
format | info:eu-repo/semantics/article |
id | cern-1405003 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2011 |
record_format | invenio |
spelling | cern-14050032023-07-20T15:06:32Z http://cds.cern.ch/record/1423005 eng Artoos, K Collette, C Esposito, M Fernandez Carmona, P Guinchard, M Hauviller, C Janssens, S Kuzmin, A Leuxe, R Moron Ballester, R Status of a study of stabilization and fine positioning of CLIC quadrupoles to the nanometre level Accelerators and Storage Rings 9: Technology for normal conducting higher energy linear accelerators Mechanical stability to the nanometre and below is required for the Compact Linear Collider (CLIC) quadrupoles to frequencies as low as 1 Hz. An active stabilization and positioning system based on very stiff piezo electric actuators and inertial reference masses is under study for the Main Beam Quadrupoles (MBQ). The stiff support was selected for robustness against direct forces and for the option of incrementally repositioning the magnet with nanometre resolution. The technical feasibility was demonstrated by a representative test mass being stabilized and repositioned to the required level in the vertical and lateral direction. Technical issues were identified and the development programme of the support, sensors, and controller was continued to increase the performance, integrate the system in the overall controller, adapt to the accelerator environment, and reduce costs. The improvements are implemented in models, test benches, and design of the first stabilized prototype CLIC magnet. The characterization of vibration sources was extended to forces acting directly on the magnet, such as water-cooling induced vibrations. This paper shows the achievements, improvements, and an outlook on further R&D. info:eu-repo/grantAgreement/EC/FP7/227579 info:eu-repo/semantics/openAccess Education Level info:eu-repo/semantics/article http://cds.cern.ch/record/1423005 2011-12-06 |
spellingShingle | Accelerators and Storage Rings 9: Technology for normal conducting higher energy linear accelerators Artoos, K Collette, C Esposito, M Fernandez Carmona, P Guinchard, M Hauviller, C Janssens, S Kuzmin, A Leuxe, R Moron Ballester, R Status of a study of stabilization and fine positioning of CLIC quadrupoles to the nanometre level |
title | Status of a study of stabilization and fine positioning of CLIC quadrupoles to the nanometre level |
title_full | Status of a study of stabilization and fine positioning of CLIC quadrupoles to the nanometre level |
title_fullStr | Status of a study of stabilization and fine positioning of CLIC quadrupoles to the nanometre level |
title_full_unstemmed | Status of a study of stabilization and fine positioning of CLIC quadrupoles to the nanometre level |
title_short | Status of a study of stabilization and fine positioning of CLIC quadrupoles to the nanometre level |
title_sort | status of a study of stabilization and fine positioning of clic quadrupoles to the nanometre level |
topic | Accelerators and Storage Rings 9: Technology for normal conducting higher energy linear accelerators |
url | http://cds.cern.ch/record/1423005 http://cds.cern.ch/record/1423005 |
work_keys_str_mv | AT artoosk statusofastudyofstabilizationandfinepositioningofclicquadrupolestothenanometrelevel AT collettec statusofastudyofstabilizationandfinepositioningofclicquadrupolestothenanometrelevel AT espositom statusofastudyofstabilizationandfinepositioningofclicquadrupolestothenanometrelevel AT fernandezcarmonap statusofastudyofstabilizationandfinepositioningofclicquadrupolestothenanometrelevel AT guinchardm statusofastudyofstabilizationandfinepositioningofclicquadrupolestothenanometrelevel AT hauvillerc statusofastudyofstabilizationandfinepositioningofclicquadrupolestothenanometrelevel AT janssenss statusofastudyofstabilizationandfinepositioningofclicquadrupolestothenanometrelevel AT kuzmina statusofastudyofstabilizationandfinepositioningofclicquadrupolestothenanometrelevel AT leuxer statusofastudyofstabilizationandfinepositioningofclicquadrupolestothenanometrelevel AT moronballesterr statusofastudyofstabilizationandfinepositioningofclicquadrupolestothenanometrelevel |