Cargando…

2 MW Active Bouncer Converter Design for Long Pulse Klystron Modulators

This paper presents some design issues of a 2 MW interleaved buck converter which is used as an active bouncer droop compensator for a 5.5MW long pulse klystron modulator. This novel design concept presents many challenges in terms of voltage ripple versus pulse rise-time. Issues related to the volt...

Descripción completa

Detalles Bibliográficos
Autor principal: Aguglia, D
Lenguaje:eng
Publicado: 2012
Materias:
Acceso en línea:http://cds.cern.ch/record/1419793
Descripción
Sumario:This paper presents some design issues of a 2 MW interleaved buck converter which is used as an active bouncer droop compensator for a 5.5MW long pulse klystron modulator. This novel design concept presents many challenges in terms of voltage ripple versus pulse rise-time. Issues related to the voltage ripple specification versus output filter design are discussed in detail. The design study is analyzed analytically, simulated numerically and is validated by experimental results obtained from a full power prototype.