Cargando…
Error Analysis for TRIC based Fast BCT acquisitions in the CERN PS ans PSB ejection lines
This paper addresses the Beam Intensity reproducibility as measured by the recently consolidated TRIC based fast BCT acquisition systems, in the ejection lines of CERN PS Booster (PSB) and Proton Synchrotron (PS). The results shown validate the expected measurement precision of 1% as set as a goal f...
Autores principales: | Andersen, M, Belohrad, D, Jensen, L |
---|---|
Lenguaje: | eng |
Publicado: |
2012
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1420562 |
Ejemplares similares
-
FBCT fast intensity measurement using TRIC cards
por: Allica, J C, et al.
Publicado: (2015) -
Upgrade of the CERN PSB/CPS Fast Intensity Measurements
por: Monera Martinez, A, et al.
Publicado: (2011) -
The LHC Fast BCT system: A comparison of Design Parameters with Initial Performance
por: Belohrad, D, et al.
Publicado: (2010) -
The 2010 LHC ring Fast BCT measurement system and its main sources of uncertainties
por: Belohrad, D, et al.
Publicado: (2010) -
The optics of the fast ejections of the CERN PS
por: Risselada, Thys
Publicado: (1989)