Cargando…

In Situ Calibration of Rotating Sensor Coils for Magnet Testing

An in situ procedure for calibrating equivalent magnetic area and rotation radius of rotating coils is proposed for testing accelerator magnets shorter than the measuring coil. The procedure exploits measurements of magnetic field and mechanical displacement inside a reference quadrupole magnet. In...

Descripción completa

Detalles Bibliográficos
Autores principales: Arpaia, P, Buzio, M, Golluccio, G, Walckiers, L
Lenguaje:eng
Publicado: 2012
Materias:
Acceso en línea:https://dx.doi.org/10.1063/1.3675578
http://cds.cern.ch/record/1421566
_version_ 1780924163470393344
author Arpaia, P
Buzio, M
Golluccio, G
Walckiers, L
author_facet Arpaia, P
Buzio, M
Golluccio, G
Walckiers, L
author_sort Arpaia, P
collection CERN
description An in situ procedure for calibrating equivalent magnetic area and rotation radius of rotating coils is proposed for testing accelerator magnets shorter than the measuring coil. The procedure exploits measurements of magnetic field and mechanical displacement inside a reference quadrupole magnet. In a quadrupole field, an offset between the magnet and coil rotation axes gives rise to a dipole component in the field series expansion. The measurements of the focusing strength, the displacement, and the resulting dipole term allow the equivalent area and radius of the coil to be determined analytically. The procedure improves the accuracy of coils with large geometrical irregularities in the winding. This is essential for short magnets where the coil dimensions constrain the measurement accuracy. Experimental results on different coils measuring small-aperture permanent magnets are shown.
id cern-1421566
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2012
record_format invenio
spelling cern-14215662019-09-30T06:29:59Zdoi:10.1063/1.3675578http://cds.cern.ch/record/1421566engArpaia, PBuzio, MGolluccio, GWalckiers, LIn Situ Calibration of Rotating Sensor Coils for Magnet TestingAccelerators and Storage RingsAn in situ procedure for calibrating equivalent magnetic area and rotation radius of rotating coils is proposed for testing accelerator magnets shorter than the measuring coil. The procedure exploits measurements of magnetic field and mechanical displacement inside a reference quadrupole magnet. In a quadrupole field, an offset between the magnet and coil rotation axes gives rise to a dipole component in the field series expansion. The measurements of the focusing strength, the displacement, and the resulting dipole term allow the equivalent area and radius of the coil to be determined analytically. The procedure improves the accuracy of coils with large geometrical irregularities in the winding. This is essential for short magnets where the coil dimensions constrain the measurement accuracy. Experimental results on different coils measuring small-aperture permanent magnets are shown.CERN-ATS-2012-018oai:cds.cern.ch:14215662012-02-03
spellingShingle Accelerators and Storage Rings
Arpaia, P
Buzio, M
Golluccio, G
Walckiers, L
In Situ Calibration of Rotating Sensor Coils for Magnet Testing
title In Situ Calibration of Rotating Sensor Coils for Magnet Testing
title_full In Situ Calibration of Rotating Sensor Coils for Magnet Testing
title_fullStr In Situ Calibration of Rotating Sensor Coils for Magnet Testing
title_full_unstemmed In Situ Calibration of Rotating Sensor Coils for Magnet Testing
title_short In Situ Calibration of Rotating Sensor Coils for Magnet Testing
title_sort in situ calibration of rotating sensor coils for magnet testing
topic Accelerators and Storage Rings
url https://dx.doi.org/10.1063/1.3675578
http://cds.cern.ch/record/1421566
work_keys_str_mv AT arpaiap insitucalibrationofrotatingsensorcoilsformagnettesting
AT buziom insitucalibrationofrotatingsensorcoilsformagnettesting
AT gollucciog insitucalibrationofrotatingsensorcoilsformagnettesting
AT walckiersl insitucalibrationofrotatingsensorcoilsformagnettesting