Cargando…
Magnetic measurements of a CEA/IPHI 28.5° dipole for the Linac4 diagnostic beam line
This reports summarizes the results of a recent test campaign carried out on a spectrometer dipole for the Linac4 diagnostic line. These results include point-like measurements done with NMR and Hall effect probes and are intended as a cross-check of a more extensive campaign carried out at Sigma Ph...
Autores principales: | , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2012
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1434711 |
Sumario: | This reports summarizes the results of a recent test campaign carried out on a spectrometer dipole for the Linac4 diagnostic line. These results include point-like measurements done with NMR and Hall effect probes and are intended as a cross-check of a more extensive campaign carried out at Sigma Phi. They are aimed specifically at the issue of the reproducibility of the field on different cycling conditions. In the Appendix, a field control algorithm which can be used to guarantee the requested 0.1% reproducibility is spelled out in full detail. |
---|