Cargando…

Magnetic measurements of a CEA/IPHI 28.5° dipole for the Linac4 diagnostic beam line

This reports summarizes the results of a recent test campaign carried out on a spectrometer dipole for the Linac4 diagnostic line. These results include point-like measurements done with NMR and Hall effect probes and are intended as a cross-check of a more extensive campaign carried out at Sigma Ph...

Descripción completa

Detalles Bibliográficos
Autores principales: Buzio, M, Cote, D, Chritin, R, Galbraith, P, Giloteaux, D
Lenguaje:eng
Publicado: 2012
Materias:
Acceso en línea:http://cds.cern.ch/record/1434711
_version_ 1780924452176920576
author Buzio, M
Cote, D
Chritin, R
Galbraith, P
Giloteaux, D
author_facet Buzio, M
Cote, D
Chritin, R
Galbraith, P
Giloteaux, D
author_sort Buzio, M
collection CERN
description This reports summarizes the results of a recent test campaign carried out on a spectrometer dipole for the Linac4 diagnostic line. These results include point-like measurements done with NMR and Hall effect probes and are intended as a cross-check of a more extensive campaign carried out at Sigma Phi. They are aimed specifically at the issue of the reproducibility of the field on different cycling conditions. In the Appendix, a field control algorithm which can be used to guarantee the requested 0.1% reproducibility is spelled out in full detail.
id cern-1434711
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2012
record_format invenio
spelling cern-14347112019-09-30T06:29:59Zhttp://cds.cern.ch/record/1434711engBuzio, MCote, DChritin, RGalbraith, PGiloteaux, DMagnetic measurements of a CEA/IPHI 28.5° dipole for the Linac4 diagnostic beam lineAccelerators and Storage RingsThis reports summarizes the results of a recent test campaign carried out on a spectrometer dipole for the Linac4 diagnostic line. These results include point-like measurements done with NMR and Hall effect probes and are intended as a cross-check of a more extensive campaign carried out at Sigma Phi. They are aimed specifically at the issue of the reproducibility of the field on different cycling conditions. In the Appendix, a field control algorithm which can be used to guarantee the requested 0.1% reproducibility is spelled out in full detail.CERN-ATS-Note-2012-035 TECHoai:cds.cern.ch:14347112012-03-27
spellingShingle Accelerators and Storage Rings
Buzio, M
Cote, D
Chritin, R
Galbraith, P
Giloteaux, D
Magnetic measurements of a CEA/IPHI 28.5° dipole for the Linac4 diagnostic beam line
title Magnetic measurements of a CEA/IPHI 28.5° dipole for the Linac4 diagnostic beam line
title_full Magnetic measurements of a CEA/IPHI 28.5° dipole for the Linac4 diagnostic beam line
title_fullStr Magnetic measurements of a CEA/IPHI 28.5° dipole for the Linac4 diagnostic beam line
title_full_unstemmed Magnetic measurements of a CEA/IPHI 28.5° dipole for the Linac4 diagnostic beam line
title_short Magnetic measurements of a CEA/IPHI 28.5° dipole for the Linac4 diagnostic beam line
title_sort magnetic measurements of a cea/iphi 28.5° dipole for the linac4 diagnostic beam line
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/1434711
work_keys_str_mv AT buziom magneticmeasurementsofaceaiphi285dipoleforthelinac4diagnosticbeamline
AT coted magneticmeasurementsofaceaiphi285dipoleforthelinac4diagnosticbeamline
AT chritinr magneticmeasurementsofaceaiphi285dipoleforthelinac4diagnosticbeamline
AT galbraithp magneticmeasurementsofaceaiphi285dipoleforthelinac4diagnosticbeamline
AT giloteauxd magneticmeasurementsofaceaiphi285dipoleforthelinac4diagnosticbeamline