Cargando…
Fabrication, Tuning, Treatment and Testing of Two 3.5 Cell Photo-Injektor Cavities for the ELBE Linac
As part of a CRADA (Cooperative Research and Development Agreement) between Helmholtz-Zentrum Dresden-Rossendorf (HZDR) and Thomas Jefferson Lab National Accelerator Facility (TJNAF) we have fabricated and tested two 1.3 GHz 3.5 cell photo-injector cavities from polycrystalline RRR niobium and large...
Autores principales: | Arnold, A, Murcek, P, Teichert, J, Xiang, R, Eremeev, G V, Kneisel, P, Stirbet, M, Turlington, L |
---|---|
Formato: | info:eu-repo/semantics/article |
Lenguaje: | eng |
Publicado: |
2011
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1436389 |
Ejemplares similares
-
Modified SRF Photoinjector for the ELBE at HZDR
por: Murcek, P, et al.
Publicado: (2012) -
Operation of the superconducting RF photo gun at ELBE
por: Teichert, J, et al.
Publicado: (2011) -
Operation of the superconducting RF photo gun at ELBE
por: Teichert, J, et al.
Publicado: (2012) -
Status of the SRF Gun Operation at ELBE
por: Teichert, J, et al.
Publicado: (2010) -
The elbe accelerator facility starts operation with the superconducting rf gun
por: Xiang, R, et al.
Publicado: (2010)