Cargando…

Electron cloud observations through synchronous phase measurements

The electron cloud in vacuum pipes of accelerators of positively charged particle beams causes a beam energy loss which could be estimated from the synchronous phase. Measurements done with beams of 75 ns, 50 ns, and 25 ns bunch spacing in the LHC for some fills in 2010 and 2011 show that the averag...

Descripción completa

Detalles Bibliográficos
Autores principales: Esteban Müller, J F, Baudrenghien, P, Mastoridis, T, Papotti, G, Shaposhnikova, E, Valuch, D
Lenguaje:eng
Publicado: 2012
Materias:
Acceso en línea:http://cds.cern.ch/record/1436987
_version_ 1780924501428535296
author Esteban Müller, J F
Baudrenghien, P
Mastoridis, T
Papotti, G
Shaposhnikova, E
Valuch, D
author_facet Esteban Müller, J F
Baudrenghien, P
Mastoridis, T
Papotti, G
Shaposhnikova, E
Valuch, D
author_sort Esteban Müller, J F
collection CERN
description The electron cloud in vacuum pipes of accelerators of positively charged particle beams causes a beam energy loss which could be estimated from the synchronous phase. Measurements done with beams of 75 ns, 50 ns, and 25 ns bunch spacing in the LHC for some fills in 2010 and 2011 show that the average energy loss depends on the total beam intensity in the ring. Later measurements during the scrubbing run with 50 ns beams show the reduction of the electron cloud due to scrubbing. Finally, measurements of the individual bunch phase give us information about the electron cloud build-up inside the batch and from batch to batch.
id cern-1436987
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2012
record_format invenio
spelling cern-14369872019-09-30T06:29:59Zhttp://cds.cern.ch/record/1436987engEsteban Müller, J FBaudrenghien, PMastoridis, TPapotti, GShaposhnikova, EValuch, DElectron cloud observations through synchronous phase measurementsAccelerators and Storage RingsThe electron cloud in vacuum pipes of accelerators of positively charged particle beams causes a beam energy loss which could be estimated from the synchronous phase. Measurements done with beams of 75 ns, 50 ns, and 25 ns bunch spacing in the LHC for some fills in 2010 and 2011 show that the average energy loss depends on the total beam intensity in the ring. Later measurements during the scrubbing run with 50 ns beams show the reduction of the electron cloud due to scrubbing. Finally, measurements of the individual bunch phase give us information about the electron cloud build-up inside the batch and from batch to batch.CERN-ATS-Note-2012-036 PERFoai:cds.cern.ch:14369872012-04-03
spellingShingle Accelerators and Storage Rings
Esteban Müller, J F
Baudrenghien, P
Mastoridis, T
Papotti, G
Shaposhnikova, E
Valuch, D
Electron cloud observations through synchronous phase measurements
title Electron cloud observations through synchronous phase measurements
title_full Electron cloud observations through synchronous phase measurements
title_fullStr Electron cloud observations through synchronous phase measurements
title_full_unstemmed Electron cloud observations through synchronous phase measurements
title_short Electron cloud observations through synchronous phase measurements
title_sort electron cloud observations through synchronous phase measurements
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/1436987
work_keys_str_mv AT estebanmullerjf electroncloudobservationsthroughsynchronousphasemeasurements
AT baudrenghienp electroncloudobservationsthroughsynchronousphasemeasurements
AT mastoridist electroncloudobservationsthroughsynchronousphasemeasurements
AT papottig electroncloudobservationsthroughsynchronousphasemeasurements
AT shaposhnikovae electroncloudobservationsthroughsynchronousphasemeasurements
AT valuchd electroncloudobservationsthroughsynchronousphasemeasurements