Cargando…

ALICE spectrometer polarity reversal

The external crossing-angle bump in IR2 of LHC partly compensates the crossing angle created by the ALICE spectrometer. In view of the spectrometer polarity reversal requested by ALICE during the 2011 Pb-Pb run, a fast procedure consisting in reversing IP2 external crossing angle after ramp and sque...

Descripción completa

Detalles Bibliográficos
Autores principales: Alemany-Fernandez, R, Hemelsoet, G H, Jowett, J M, Lamont, M, Manglunki, D, Redaelli, S, Schaumann, M, Versteegen, R, Wenninger, J
Lenguaje:eng
Publicado: 2012
Materias:
Acceso en línea:http://cds.cern.ch/record/1441694
_version_ 1780924680185577472
author Alemany-Fernandez, R
Hemelsoet, G H
Jowett, J M
Lamont, M
Manglunki, D
Redaelli, S
Schaumann, M
Versteegen, R
Wenninger, J
author_facet Alemany-Fernandez, R
Hemelsoet, G H
Jowett, J M
Lamont, M
Manglunki, D
Redaelli, S
Schaumann, M
Versteegen, R
Wenninger, J
author_sort Alemany-Fernandez, R
collection CERN
description The external crossing-angle bump in IR2 of LHC partly compensates the crossing angle created by the ALICE spectrometer. In view of the spectrometer polarity reversal requested by ALICE during the 2011 Pb-Pb run, a fast procedure consisting in reversing IP2 external crossing angle after ramp and squeeze of beams was envisaged. This requires a passage through zero external crossing angle, exposing beams to beam-beam interactions at parasitic encounters where normalized separation is less than one sigma. A test of the reversal at the end of physics fill no. 2319 showed that beam sizes are large enough at these locations not to have significant effects on intensity or emittance. Consequently, the fast polarity reversal procedure was validated and the full operational cycle was tested with a few bunches before adoption in the future physics fills.
id cern-1441694
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2012
record_format invenio
spelling cern-14416942019-09-30T06:29:59Zhttp://cds.cern.ch/record/1441694engAlemany-Fernandez, RHemelsoet, G HJowett, J MLamont, MManglunki, DRedaelli, SSchaumann, MVersteegen, RWenninger, JALICE spectrometer polarity reversalAccelerators and Storage RingsThe external crossing-angle bump in IR2 of LHC partly compensates the crossing angle created by the ALICE spectrometer. In view of the spectrometer polarity reversal requested by ALICE during the 2011 Pb-Pb run, a fast procedure consisting in reversing IP2 external crossing angle after ramp and squeeze of beams was envisaged. This requires a passage through zero external crossing angle, exposing beams to beam-beam interactions at parasitic encounters where normalized separation is less than one sigma. A test of the reversal at the end of physics fill no. 2319 showed that beam sizes are large enough at these locations not to have significant effects on intensity or emittance. Consequently, the fast polarity reversal procedure was validated and the full operational cycle was tested with a few bunches before adoption in the future physics fills.CERN-ATS-Note-2012-039 MDoai:cds.cern.ch:14416942012-04-14
spellingShingle Accelerators and Storage Rings
Alemany-Fernandez, R
Hemelsoet, G H
Jowett, J M
Lamont, M
Manglunki, D
Redaelli, S
Schaumann, M
Versteegen, R
Wenninger, J
ALICE spectrometer polarity reversal
title ALICE spectrometer polarity reversal
title_full ALICE spectrometer polarity reversal
title_fullStr ALICE spectrometer polarity reversal
title_full_unstemmed ALICE spectrometer polarity reversal
title_short ALICE spectrometer polarity reversal
title_sort alice spectrometer polarity reversal
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/1441694
work_keys_str_mv AT alemanyfernandezr alicespectrometerpolarityreversal
AT hemelsoetgh alicespectrometerpolarityreversal
AT jowettjm alicespectrometerpolarityreversal
AT lamontm alicespectrometerpolarityreversal
AT manglunkid alicespectrometerpolarityreversal
AT redaellis alicespectrometerpolarityreversal
AT schaumannm alicespectrometerpolarityreversal
AT versteegenr alicespectrometerpolarityreversal
AT wenningerj alicespectrometerpolarityreversal