Cooling of electrically insulated high voltage electrodes down to 30 mK: Dynamic measurements

AEgIS [1] is an antimatter experiment, using high voltage electrodes at 100 mK. Two possible principles to cool these electrodes with a dilution refrigerator are investigated: the Rod and the Sandwich. Both designs are described in detail in [2]. The Sandwich design is discussed in the present work....

Descripción completa

Detalles Bibliográficos
Autores principales: Eisel, T, Bremer, J, Burghart, G, Feigl, S, Haug, F, Koettig, T
Lenguaje:eng
Publicado: 2011
Materias:
Acceso en línea:http://cds.cern.ch/record/1446621
_version_ 1780924801932591104
author Eisel, T
Bremer, J
Burghart, G
Feigl, S
Haug, F
Koettig, T
author_facet Eisel, T
Bremer, J
Burghart, G
Feigl, S
Haug, F
Koettig, T
author_sort Eisel, T
collection CERN
description AEgIS [1] is an antimatter experiment, using high voltage electrodes at 100 mK. Two possible principles to cool these electrodes with a dilution refrigerator are investigated: the Rod and the Sandwich. Both designs are described in detail in [2]. The Sandwich design is discussed in the present work. It consists of an electrically insulating sapphire plate covered with indium on both sides. Dynamic measurements are performed in order to estimate the influence of time depending heat loads on different Sandwich designs. From these data the Sandwich’s thermal diffusivity is derived and compared to previous measurements using a static heat load. The lowest resistivity of the Sandwich is achieved with an indium vapor deposition onto polished sapphire (26 cm2K4/W at 30 mK). The same sandwich shows the best, i.e. highest thermal diffusivity (0.23 mm2/s at 70 mK). However, the results of the static and the dynamic measurements show some interesting and contrary tendencies.
id cern-1446621
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2011
record_format invenio
spelling cern-14466212019-09-30T06:29:59Zhttp://cds.cern.ch/record/1446621engEisel, TBremer, JBurghart, GFeigl, SHaug, FKoettig, TCooling of electrically insulated high voltage electrodes down to 30 mK: Dynamic measurementsEngineeringAEgIS [1] is an antimatter experiment, using high voltage electrodes at 100 mK. Two possible principles to cool these electrodes with a dilution refrigerator are investigated: the Rod and the Sandwich. Both designs are described in detail in [2]. The Sandwich design is discussed in the present work. It consists of an electrically insulating sapphire plate covered with indium on both sides. Dynamic measurements are performed in order to estimate the influence of time depending heat loads on different Sandwich designs. From these data the Sandwich’s thermal diffusivity is derived and compared to previous measurements using a static heat load. The lowest resistivity of the Sandwich is achieved with an indium vapor deposition onto polished sapphire (26 cm2K4/W at 30 mK). The same sandwich shows the best, i.e. highest thermal diffusivity (0.23 mm2/s at 70 mK). However, the results of the static and the dynamic measurements show some interesting and contrary tendencies.oai:cds.cern.ch:14466212011-08-01
spellingShingle Engineering
Eisel, T
Bremer, J
Burghart, G
Feigl, S
Haug, F
Koettig, T
Cooling of electrically insulated high voltage electrodes down to 30 mK: Dynamic measurements
title Cooling of electrically insulated high voltage electrodes down to 30 mK: Dynamic measurements
title_full Cooling of electrically insulated high voltage electrodes down to 30 mK: Dynamic measurements
title_fullStr Cooling of electrically insulated high voltage electrodes down to 30 mK: Dynamic measurements
title_full_unstemmed Cooling of electrically insulated high voltage electrodes down to 30 mK: Dynamic measurements
title_short Cooling of electrically insulated high voltage electrodes down to 30 mK: Dynamic measurements
title_sort cooling of electrically insulated high voltage electrodes down to 30 mk: dynamic measurements
topic Engineering
url http://cds.cern.ch/record/1446621
work_keys_str_mv AT eiselt coolingofelectricallyinsulatedhighvoltageelectrodesdownto30mkdynamicmeasurements
AT bremerj coolingofelectricallyinsulatedhighvoltageelectrodesdownto30mkdynamicmeasurements
AT burghartg coolingofelectricallyinsulatedhighvoltageelectrodesdownto30mkdynamicmeasurements
AT feigls coolingofelectricallyinsulatedhighvoltageelectrodesdownto30mkdynamicmeasurements
AT haugf coolingofelectricallyinsulatedhighvoltageelectrodesdownto30mkdynamicmeasurements
AT koettigt coolingofelectricallyinsulatedhighvoltageelectrodesdownto30mkdynamicmeasurements