Cargando…

Strategy and validation of fiducialisation for the pre-alignment of CLIC components

The feasibility of the high energy e+ e- linear collider CLIC (Compact Linear Collider) is very dependent on the ability to accurately pre-align its components. There are two 20 km long Main Linacs which meet in an interaction point (IP). The Main Linacs are composed of thousands of 2 m long modules...

Descripción completa

Detalles Bibliográficos
Autores principales: Griffet, S, Cherif, A, Kemppinen, J, Mainaud Durand, H, Rude, V, Sterbini, G
Lenguaje:eng
Publicado: 2012
Materias:
Acceso en línea:http://cds.cern.ch/record/1451293
_version_ 1780924935121666048
author Griffet, S
Cherif, A
Kemppinen, J
Mainaud Durand, H
Rude, V
Sterbini, G
author_facet Griffet, S
Cherif, A
Kemppinen, J
Mainaud Durand, H
Rude, V
Sterbini, G
author_sort Griffet, S
collection CERN
description The feasibility of the high energy e+ e- linear collider CLIC (Compact Linear Collider) is very dependent on the ability to accurately pre-align its components. There are two 20 km long Main Linacs which meet in an interaction point (IP). The Main Linacs are composed of thousands of 2 m long modules. One of the challenges is to meet very tight alignment tolerances at the level of CLIC module: for example, the magnetic centre of a Drive Beam Quad needs to be aligned within 20 µm rms with respect to a straight line. Such accuracies cannot be achieved using usual measurement devices. Thus it is necessary to work in close collaboration with the metrology lab. To test and improve many critical points, including alignment, a CLIC mock-up is being assembled at CERN. This paper describes the application of the strategy of fiducialisation for the pre-alignment of CLIC mock-up components. It also deals with the first results obtained by performing measurements using a CMM (Coordinate Measuring Machine) to ensure the fiducialisation, using a Laser Tracker to adjust or check components’ positions on a girder and finally using a Measuring Arm to perform dimensional control after assembling steps.
id cern-1451293
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2012
record_format invenio
spelling cern-14512932023-07-20T15:05:48Zhttp://cds.cern.ch/record/1451293engGriffet, SCherif, AKemppinen, JMainaud Durand, HRude, VSterbini, GStrategy and validation of fiducialisation for the pre-alignment of CLIC componentsAccelerators and Storage RingsThe feasibility of the high energy e+ e- linear collider CLIC (Compact Linear Collider) is very dependent on the ability to accurately pre-align its components. There are two 20 km long Main Linacs which meet in an interaction point (IP). The Main Linacs are composed of thousands of 2 m long modules. One of the challenges is to meet very tight alignment tolerances at the level of CLIC module: for example, the magnetic centre of a Drive Beam Quad needs to be aligned within 20 µm rms with respect to a straight line. Such accuracies cannot be achieved using usual measurement devices. Thus it is necessary to work in close collaboration with the metrology lab. To test and improve many critical points, including alignment, a CLIC mock-up is being assembled at CERN. This paper describes the application of the strategy of fiducialisation for the pre-alignment of CLIC mock-up components. It also deals with the first results obtained by performing measurements using a CMM (Coordinate Measuring Machine) to ensure the fiducialisation, using a Laser Tracker to adjust or check components’ positions on a girder and finally using a Measuring Arm to perform dimensional control after assembling steps.CERN-ATS-2012-078CLIC-Note-963oai:cds.cern.ch:14512932012-05-23
spellingShingle Accelerators and Storage Rings
Griffet, S
Cherif, A
Kemppinen, J
Mainaud Durand, H
Rude, V
Sterbini, G
Strategy and validation of fiducialisation for the pre-alignment of CLIC components
title Strategy and validation of fiducialisation for the pre-alignment of CLIC components
title_full Strategy and validation of fiducialisation for the pre-alignment of CLIC components
title_fullStr Strategy and validation of fiducialisation for the pre-alignment of CLIC components
title_full_unstemmed Strategy and validation of fiducialisation for the pre-alignment of CLIC components
title_short Strategy and validation of fiducialisation for the pre-alignment of CLIC components
title_sort strategy and validation of fiducialisation for the pre-alignment of clic components
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/1451293
work_keys_str_mv AT griffets strategyandvalidationoffiducialisationfortheprealignmentofcliccomponents
AT cherifa strategyandvalidationoffiducialisationfortheprealignmentofcliccomponents
AT kemppinenj strategyandvalidationoffiducialisationfortheprealignmentofcliccomponents
AT mainauddurandh strategyandvalidationoffiducialisationfortheprealignmentofcliccomponents
AT rudev strategyandvalidationoffiducialisationfortheprealignmentofcliccomponents
AT sterbinig strategyandvalidationoffiducialisationfortheprealignmentofcliccomponents