Cargando…

Calibration of the RPC working voltage in the CMS experiment

The Resistive Plate Chambers (RPCs) are employed in the CMS experiment at the LHC as dedicated trigger system both in the barrel and in the endcap. The working voltage of all the RPCs installed in CMS has been tuned in 2011 with a dedicated High Voltage scan with LHC collisions during the low lumino...

Descripción completa

Detalles Bibliográficos
Autor principal: Costantini, Silvia
Lenguaje:eng
Publicado: 2012
Materias:
Acceso en línea:http://cds.cern.ch/record/1457409
_version_ 1780925111325425664
author Costantini, Silvia
author_facet Costantini, Silvia
author_sort Costantini, Silvia
collection CERN
description The Resistive Plate Chambers (RPCs) are employed in the CMS experiment at the LHC as dedicated trigger system both in the barrel and in the endcap. The working voltage of all the RPCs installed in CMS has been tuned in 2011 with a dedicated High Voltage scan with LHC collisions during the low luminosity operations. This note presents procedures and results of the High Voltage calibration, with emphasis on the RPC detector uniformity and stability during the 2011 data taking period.
id cern-1457409
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2012
record_format invenio
spelling cern-14574092019-09-30T06:29:59Zhttp://cds.cern.ch/record/1457409engCostantini, SilviaCalibration of the RPC working voltage in the CMS experimentDetectors and Experimental TechniquesThe Resistive Plate Chambers (RPCs) are employed in the CMS experiment at the LHC as dedicated trigger system both in the barrel and in the endcap. The working voltage of all the RPCs installed in CMS has been tuned in 2011 with a dedicated High Voltage scan with LHC collisions during the low luminosity operations. This note presents procedures and results of the High Voltage calibration, with emphasis on the RPC detector uniformity and stability during the 2011 data taking period.CMS-CR-2012-055oai:cds.cern.ch:14574092012-04-30
spellingShingle Detectors and Experimental Techniques
Costantini, Silvia
Calibration of the RPC working voltage in the CMS experiment
title Calibration of the RPC working voltage in the CMS experiment
title_full Calibration of the RPC working voltage in the CMS experiment
title_fullStr Calibration of the RPC working voltage in the CMS experiment
title_full_unstemmed Calibration of the RPC working voltage in the CMS experiment
title_short Calibration of the RPC working voltage in the CMS experiment
title_sort calibration of the rpc working voltage in the cms experiment
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/1457409
work_keys_str_mv AT costantinisilvia calibrationoftherpcworkingvoltageinthecmsexperiment