Cargando…

Overview of the Beam diagnostics in the Medaustron Accelerator:Design choices and test Beam commissioning

The MedAustron centre is a synchrotron based accelerator complex for cancer treatment and clinical and non-clinical research with protons and light ions, currently under construction in Wiener Neustadt, Austria. The accelerator complex is based on the CERN-PIMMS study [1] and its technical implement...

Descripción completa

Detalles Bibliográficos
Autores principales: Osmic, F, Feurstein, M, Gyorgy, A, Kerschbaum, A, Repovz, M, Schwarz, S, Neustadt, W, Burtin, G
Lenguaje:eng
Publicado: 2012
Materias:
Acceso en línea:http://cds.cern.ch/record/1459552
_version_ 1780925190810632192
author Osmic, F
Feurstein, M
Gyorgy, A
Kerschbaum, A
Repovz, M
Schwarz, S
Neustadt, W
Burtin, G
author_facet Osmic, F
Feurstein, M
Gyorgy, A
Kerschbaum, A
Repovz, M
Schwarz, S
Neustadt, W
Burtin, G
author_sort Osmic, F
collection CERN
description The MedAustron centre is a synchrotron based accelerator complex for cancer treatment and clinical and non-clinical research with protons and light ions, currently under construction in Wiener Neustadt, Austria. The accelerator complex is based on the CERN-PIMMS study [1] and its technical implementation by the Italian CNAO foundation in Pavia [2]. The MedAustron beam diagnostics system is based on sixteen different monitor types (153 devices in total) and will allow measuring all relevant beam parameters from the source to the irradiation rooms. The monitors will have to cope with large intensities and energy ranges. Currently, one ion source, the low energy beam transfer line and the RFQ are being commissioned in the Injector Test Stand (ITS) at CERN. This paper gives an overview of all beam monitors foreseen for the MedAustron accelerator, elaborates some of the design choices and reports the first beam commissioning results from the ITS.
id cern-1459552
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2012
record_format invenio
spelling cern-14595522022-08-17T13:25:35Zhttp://cds.cern.ch/record/1459552engOsmic, FFeurstein, MGyorgy, AKerschbaum, ARepovz, MSchwarz, SNeustadt, WBurtin, GOverview of the Beam diagnostics in the Medaustron Accelerator:Design choices and test Beam commissioningAccelerators and Storage RingsThe MedAustron centre is a synchrotron based accelerator complex for cancer treatment and clinical and non-clinical research with protons and light ions, currently under construction in Wiener Neustadt, Austria. The accelerator complex is based on the CERN-PIMMS study [1] and its technical implementation by the Italian CNAO foundation in Pavia [2]. The MedAustron beam diagnostics system is based on sixteen different monitor types (153 devices in total) and will allow measuring all relevant beam parameters from the source to the irradiation rooms. The monitors will have to cope with large intensities and energy ranges. Currently, one ion source, the low energy beam transfer line and the RFQ are being commissioned in the Injector Test Stand (ITS) at CERN. This paper gives an overview of all beam monitors foreseen for the MedAustron accelerator, elaborates some of the design choices and reports the first beam commissioning results from the ITS.CERN-ATS-2012-110oai:cds.cern.ch:14595522012-05-20
spellingShingle Accelerators and Storage Rings
Osmic, F
Feurstein, M
Gyorgy, A
Kerschbaum, A
Repovz, M
Schwarz, S
Neustadt, W
Burtin, G
Overview of the Beam diagnostics in the Medaustron Accelerator:Design choices and test Beam commissioning
title Overview of the Beam diagnostics in the Medaustron Accelerator:Design choices and test Beam commissioning
title_full Overview of the Beam diagnostics in the Medaustron Accelerator:Design choices and test Beam commissioning
title_fullStr Overview of the Beam diagnostics in the Medaustron Accelerator:Design choices and test Beam commissioning
title_full_unstemmed Overview of the Beam diagnostics in the Medaustron Accelerator:Design choices and test Beam commissioning
title_short Overview of the Beam diagnostics in the Medaustron Accelerator:Design choices and test Beam commissioning
title_sort overview of the beam diagnostics in the medaustron accelerator:design choices and test beam commissioning
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/1459552
work_keys_str_mv AT osmicf overviewofthebeamdiagnosticsinthemedaustronacceleratordesignchoicesandtestbeamcommissioning
AT feursteinm overviewofthebeamdiagnosticsinthemedaustronacceleratordesignchoicesandtestbeamcommissioning
AT gyorgya overviewofthebeamdiagnosticsinthemedaustronacceleratordesignchoicesandtestbeamcommissioning
AT kerschbauma overviewofthebeamdiagnosticsinthemedaustronacceleratordesignchoicesandtestbeamcommissioning
AT repovzm overviewofthebeamdiagnosticsinthemedaustronacceleratordesignchoicesandtestbeamcommissioning
AT schwarzs overviewofthebeamdiagnosticsinthemedaustronacceleratordesignchoicesandtestbeamcommissioning
AT neustadtw overviewofthebeamdiagnosticsinthemedaustronacceleratordesignchoicesandtestbeamcommissioning
AT burting overviewofthebeamdiagnosticsinthemedaustronacceleratordesignchoicesandtestbeamcommissioning