Cargando…
A Comparative Study for the Clic Drive Beam Decelerator Optics
The baseline for the CLIC drive beam decelerator optics consists of a 2 m long FODO cell. This solution was adopted to have strong focusing in order to mitigate the effect of the PETS wake fields and to minimize the drive beam envelope. Taking into account the most recent PETS design, we compare the...
Autores principales: | , , |
---|---|
Lenguaje: | eng |
Publicado: |
2012
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1460134 |
_version_ | 1780925217463336960 |
---|---|
author | Sterbini, G Schulte, D Adli, E |
author_facet | Sterbini, G Schulte, D Adli, E |
author_sort | Sterbini, G |
collection | CERN |
description | The baseline for the CLIC drive beam decelerator optics consists of a 2 m long FODO cell. This solution was adopted to have strong focusing in order to mitigate the effect of the PETS wake fields and to minimize the drive beam envelope. Taking into account the most recent PETS design, we compare the performance of the baseline FODO cell with a proposal that consider twice longer FODO cell. Despite of the expected cost in terms of performance, the reduction of the complexity of the system due to the halving of the number of quadrupoles can be beneficial for the overall optimization of the decelerator design. |
id | cern-1460134 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2012 |
record_format | invenio |
spelling | cern-14601342023-07-20T15:07:23Zhttp://cds.cern.ch/record/1460134engSterbini, GSchulte, DAdli, EA Comparative Study for the Clic Drive Beam Decelerator OpticsAccelerators and Storage RingsThe baseline for the CLIC drive beam decelerator optics consists of a 2 m long FODO cell. This solution was adopted to have strong focusing in order to mitigate the effect of the PETS wake fields and to minimize the drive beam envelope. Taking into account the most recent PETS design, we compare the performance of the baseline FODO cell with a proposal that consider twice longer FODO cell. Despite of the expected cost in terms of performance, the reduction of the complexity of the system due to the halving of the number of quadrupoles can be beneficial for the overall optimization of the decelerator design.CERN-ATS-2012-143CLIC-Note-955oai:cds.cern.ch:14601342012-05-20 |
spellingShingle | Accelerators and Storage Rings Sterbini, G Schulte, D Adli, E A Comparative Study for the Clic Drive Beam Decelerator Optics |
title | A Comparative Study for the Clic Drive Beam Decelerator Optics |
title_full | A Comparative Study for the Clic Drive Beam Decelerator Optics |
title_fullStr | A Comparative Study for the Clic Drive Beam Decelerator Optics |
title_full_unstemmed | A Comparative Study for the Clic Drive Beam Decelerator Optics |
title_short | A Comparative Study for the Clic Drive Beam Decelerator Optics |
title_sort | comparative study for the clic drive beam decelerator optics |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/1460134 |
work_keys_str_mv | AT sterbinig acomparativestudyfortheclicdrivebeamdeceleratoroptics AT schulted acomparativestudyfortheclicdrivebeamdeceleratoroptics AT adlie acomparativestudyfortheclicdrivebeamdeceleratoroptics AT sterbinig comparativestudyfortheclicdrivebeamdeceleratoroptics AT schulted comparativestudyfortheclicdrivebeamdeceleratoroptics AT adlie comparativestudyfortheclicdrivebeamdeceleratoroptics |