Cargando…

Comparison of LHC collimator beam-based alignment to BPM-Interpolated centers

The beam centers at the Large Hadron Collider collimators are determined by beam-based alignment, where both jaws of a collimator are moved in separately until a loss spike is detected on a Beam LossMonitor downstream. Orbit drifts of more than a few hundred micrometers cannot be tolerated, as they...

Descripción completa

Detalles Bibliográficos
Autores principales: Valentino, G, Sammut, N, Assmann, R W, Bruce, R, Muller, G J, Redaelli, S, Rossi, A, Lari, L
Lenguaje:eng
Publicado: 2012
Materias:
Acceso en línea:http://cds.cern.ch/record/1464088
_version_ 1780925348923310080
author Valentino, G
Sammut, N
Assmann, R W
Bruce, R
Muller, G J
Redaelli, S
Rossi, A
Lari, L
author_facet Valentino, G
Sammut, N
Assmann, R W
Bruce, R
Muller, G J
Redaelli, S
Rossi, A
Lari, L
author_sort Valentino, G
collection CERN
description The beam centers at the Large Hadron Collider collimators are determined by beam-based alignment, where both jaws of a collimator are moved in separately until a loss spike is detected on a Beam LossMonitor downstream. Orbit drifts of more than a few hundred micrometers cannot be tolerated, as they would compromise the performance of the collimation system. Beam Position Monitors (BPMs) are installed at various locations around the LHC ring, and a linear interpolation of the orbit can be obtained at the collimator positions. In this paper, the results obtained from beam-based alignment are compared with the orbit interpolated from the BPM data throughout the 2011 and 2012 LHC proton runs.
id cern-1464088
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2012
record_format invenio
spelling cern-14640882022-08-17T13:31:44Zhttp://cds.cern.ch/record/1464088engValentino, GSammut, NAssmann, R WBruce, RMuller, G JRedaelli, SRossi, ALari, LComparison of LHC collimator beam-based alignment to BPM-Interpolated centersAccelerators and Storage RingsThe beam centers at the Large Hadron Collider collimators are determined by beam-based alignment, where both jaws of a collimator are moved in separately until a loss spike is detected on a Beam LossMonitor downstream. Orbit drifts of more than a few hundred micrometers cannot be tolerated, as they would compromise the performance of the collimation system. Beam Position Monitors (BPMs) are installed at various locations around the LHC ring, and a linear interpolation of the orbit can be obtained at the collimator positions. In this paper, the results obtained from beam-based alignment are compared with the orbit interpolated from the BPM data throughout the 2011 and 2012 LHC proton runs.CERN-ATS-2012-174oai:cds.cern.ch:14640882012-05-20
spellingShingle Accelerators and Storage Rings
Valentino, G
Sammut, N
Assmann, R W
Bruce, R
Muller, G J
Redaelli, S
Rossi, A
Lari, L
Comparison of LHC collimator beam-based alignment to BPM-Interpolated centers
title Comparison of LHC collimator beam-based alignment to BPM-Interpolated centers
title_full Comparison of LHC collimator beam-based alignment to BPM-Interpolated centers
title_fullStr Comparison of LHC collimator beam-based alignment to BPM-Interpolated centers
title_full_unstemmed Comparison of LHC collimator beam-based alignment to BPM-Interpolated centers
title_short Comparison of LHC collimator beam-based alignment to BPM-Interpolated centers
title_sort comparison of lhc collimator beam-based alignment to bpm-interpolated centers
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/1464088
work_keys_str_mv AT valentinog comparisonoflhccollimatorbeambasedalignmenttobpminterpolatedcenters
AT sammutn comparisonoflhccollimatorbeambasedalignmenttobpminterpolatedcenters
AT assmannrw comparisonoflhccollimatorbeambasedalignmenttobpminterpolatedcenters
AT brucer comparisonoflhccollimatorbeambasedalignmenttobpminterpolatedcenters
AT mullergj comparisonoflhccollimatorbeambasedalignmenttobpminterpolatedcenters
AT redaellis comparisonoflhccollimatorbeambasedalignmenttobpminterpolatedcenters
AT rossia comparisonoflhccollimatorbeambasedalignmenttobpminterpolatedcenters
AT laril comparisonoflhccollimatorbeambasedalignmenttobpminterpolatedcenters