Cargando…

Konzeption eines kryogenen Penningfallenaufbaus für SHIPTRAP und Massenbestimmung von Radionukliden um den Z=82–Schalenabschluss an ISOLTRAP

Conceptual Design of a Cryogenic Penning Trap Set–Up for SHIPTRAP and Mass Determination of Radionuclides around the Z = 82 – Shell Closure with ISOLTRAP: The Penning trap mass spectrometers SHIPTRAP/GSI and ISOLTRAP/CERN enable precise mass determination of unstable, exotic nuclei. The following de...

Descripción completa

Detalles Bibliográficos
Autor principal: Weber, Christine
Lenguaje:ger
Publicado: 2012
Materias:
Acceso en línea:http://cds.cern.ch/record/1476093
_version_ 1780925541884362752
author Weber, Christine
author_facet Weber, Christine
author_sort Weber, Christine
collection CERN
description Conceptual Design of a Cryogenic Penning Trap Set–Up for SHIPTRAP and Mass Determination of Radionuclides around the Z = 82 – Shell Closure with ISOLTRAP: The Penning trap mass spectrometers SHIPTRAP/GSI and ISOLTRAP/CERN enable precise mass determination of unstable, exotic nuclei. The following detection methods are presented: the destructive time–of–flight method (TOF–ICR) and the non–destructive Fourier Transform–Ion Cyclotron Resonance method (FT–ICR). Planned experiments with SHIPTRAP focus on transuranium elements whose low production limit their experimental investigation. The sensitive FT–ICR– detection allows the identification of stored ions as well as their mass determination. Within this thesis, a cryogenic Penning trap set–up has been designed and constructed, in order to detect and to observe the cyclotron frequency of a single singly-charged heavy ion. It consists of a vacuum system at liquid nitrogen temperature in the bore of a superconducting magnet housing a double trap set–up, a purification trap and a measurement trap. A superconducting inductance in a liquid-helium Dewar provides extreme sensitivity for detection of the cyclotron frequency. At ISOLTRAP the resonant excitation at the cyclotron frequency is detected by the time– of–flight method. Atomic masses of the radionuclides $^{145,147}\!$Cs , $^{181,183,186m,187x,196m,205}$Tl , $^{187,187m,197,208}$Pb , $^{190−197,209,215,216}$Bi , $^{203,205,229}$Fr and $\,^{214,229,230}$Ra were determined experimentally with a relative mass uncertainty of typically some 10$^{−8}$. The results were included into the atomic mass evaluation and a mass adjustment was conducted. Resulting separation energies show the expected global trend, whereas thallium and mercury isotopes reveal a deviation from this linear behaviour. This could point to unexpected nuclear structure effects as observed in nuclear and laser spectroscopic experiments.
id cern-1476093
institution Organización Europea para la Investigación Nuclear
language ger
publishDate 2012
record_format invenio
spelling cern-14760932019-09-30T06:29:59Zhttp://cds.cern.ch/record/1476093gerWeber, ChristineKonzeption eines kryogenen Penningfallenaufbaus für SHIPTRAP und Massenbestimmung von Radionukliden um den Z=82–Schalenabschluss an ISOLTRAPNuclear Physics - ExperimentDetectors and Experimental TechniquesConceptual Design of a Cryogenic Penning Trap Set–Up for SHIPTRAP and Mass Determination of Radionuclides around the Z = 82 – Shell Closure with ISOLTRAP: The Penning trap mass spectrometers SHIPTRAP/GSI and ISOLTRAP/CERN enable precise mass determination of unstable, exotic nuclei. The following detection methods are presented: the destructive time–of–flight method (TOF–ICR) and the non–destructive Fourier Transform–Ion Cyclotron Resonance method (FT–ICR). Planned experiments with SHIPTRAP focus on transuranium elements whose low production limit their experimental investigation. The sensitive FT–ICR– detection allows the identification of stored ions as well as their mass determination. Within this thesis, a cryogenic Penning trap set–up has been designed and constructed, in order to detect and to observe the cyclotron frequency of a single singly-charged heavy ion. It consists of a vacuum system at liquid nitrogen temperature in the bore of a superconducting magnet housing a double trap set–up, a purification trap and a measurement trap. A superconducting inductance in a liquid-helium Dewar provides extreme sensitivity for detection of the cyclotron frequency. At ISOLTRAP the resonant excitation at the cyclotron frequency is detected by the time– of–flight method. Atomic masses of the radionuclides $^{145,147}\!$Cs , $^{181,183,186m,187x,196m,205}$Tl , $^{187,187m,197,208}$Pb , $^{190−197,209,215,216}$Bi , $^{203,205,229}$Fr and $\,^{214,229,230}$Ra were determined experimentally with a relative mass uncertainty of typically some 10$^{−8}$. The results were included into the atomic mass evaluation and a mass adjustment was conducted. Resulting separation energies show the expected global trend, whereas thallium and mercury isotopes reveal a deviation from this linear behaviour. This could point to unexpected nuclear structure effects as observed in nuclear and laser spectroscopic experiments.oai:cds.cern.ch:14760932012-09-04T15:26:30Z
spellingShingle Nuclear Physics - Experiment
Detectors and Experimental Techniques
Weber, Christine
Konzeption eines kryogenen Penningfallenaufbaus für SHIPTRAP und Massenbestimmung von Radionukliden um den Z=82–Schalenabschluss an ISOLTRAP
title Konzeption eines kryogenen Penningfallenaufbaus für SHIPTRAP und Massenbestimmung von Radionukliden um den Z=82–Schalenabschluss an ISOLTRAP
title_full Konzeption eines kryogenen Penningfallenaufbaus für SHIPTRAP und Massenbestimmung von Radionukliden um den Z=82–Schalenabschluss an ISOLTRAP
title_fullStr Konzeption eines kryogenen Penningfallenaufbaus für SHIPTRAP und Massenbestimmung von Radionukliden um den Z=82–Schalenabschluss an ISOLTRAP
title_full_unstemmed Konzeption eines kryogenen Penningfallenaufbaus für SHIPTRAP und Massenbestimmung von Radionukliden um den Z=82–Schalenabschluss an ISOLTRAP
title_short Konzeption eines kryogenen Penningfallenaufbaus für SHIPTRAP und Massenbestimmung von Radionukliden um den Z=82–Schalenabschluss an ISOLTRAP
title_sort konzeption eines kryogenen penningfallenaufbaus für shiptrap und massenbestimmung von radionukliden um den z=82–schalenabschluss an isoltrap
topic Nuclear Physics - Experiment
Detectors and Experimental Techniques
url http://cds.cern.ch/record/1476093
work_keys_str_mv AT weberchristine konzeptioneineskryogenenpenningfallenaufbausfurshiptrapundmassenbestimmungvonradionuklidenumdenz82schalenabschlussanisoltrap