Cargando…

Calibration systems of the ATLAS Tile Calorimeter

TileCal is the hadronic calorimeter covering the most central region of the ATLAS experiment at the LHC. This sampling calorimeter uses iron plates as absorber and plastic scintillating tiles as the active material. Scintillation light produced in the tiles is transmitted by wavelength shifting fibe...

Descripción completa

Detalles Bibliográficos
Autor principal: Lundberg, O
Lenguaje:eng
Publicado: 2012
Materias:
Acceso en línea:http://cds.cern.ch/record/1476697
_version_ 1780925557265924096
author Lundberg, O
author_facet Lundberg, O
author_sort Lundberg, O
collection CERN
description TileCal is the hadronic calorimeter covering the most central region of the ATLAS experiment at the LHC. This sampling calorimeter uses iron plates as absorber and plastic scintillating tiles as the active material. Scintillation light produced in the tiles is transmitted by wavelength shifting fibers to photomultiplier tubes (PMTs). The resulting electronic signals from the over 10000 PMTs are measured and digitized before being transferred to off-detector data-acquisition systems. A multi-faceted calibration system allows to monitor and equalize the calorimeter response at each stage of the signal production, from scintillation light to digitization. This calibration system is based on signal generation from different sources: a Cs radioactive source, laser light, charge injection and minimum bias events produced in proton-proton collisions. This talk presents a brief description of the different TileCal calibration systems and presents the latest results on their performance in terms of calibration factors, linearity and stability.
id cern-1476697
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2012
record_format invenio
spelling cern-14766972019-09-30T06:29:59Zhttp://cds.cern.ch/record/1476697engLundberg, OCalibration systems of the ATLAS Tile CalorimeterDetectors and Experimental TechniquesTileCal is the hadronic calorimeter covering the most central region of the ATLAS experiment at the LHC. This sampling calorimeter uses iron plates as absorber and plastic scintillating tiles as the active material. Scintillation light produced in the tiles is transmitted by wavelength shifting fibers to photomultiplier tubes (PMTs). The resulting electronic signals from the over 10000 PMTs are measured and digitized before being transferred to off-detector data-acquisition systems. A multi-faceted calibration system allows to monitor and equalize the calorimeter response at each stage of the signal production, from scintillation light to digitization. This calibration system is based on signal generation from different sources: a Cs radioactive source, laser light, charge injection and minimum bias events produced in proton-proton collisions. This talk presents a brief description of the different TileCal calibration systems and presents the latest results on their performance in terms of calibration factors, linearity and stability.ATL-TILECAL-SLIDE-2012-509oai:cds.cern.ch:14766972012-09-07
spellingShingle Detectors and Experimental Techniques
Lundberg, O
Calibration systems of the ATLAS Tile Calorimeter
title Calibration systems of the ATLAS Tile Calorimeter
title_full Calibration systems of the ATLAS Tile Calorimeter
title_fullStr Calibration systems of the ATLAS Tile Calorimeter
title_full_unstemmed Calibration systems of the ATLAS Tile Calorimeter
title_short Calibration systems of the ATLAS Tile Calorimeter
title_sort calibration systems of the atlas tile calorimeter
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/1476697
work_keys_str_mv AT lundbergo calibrationsystemsoftheatlastilecalorimeter