Development of a Readout Link Board for theTileCal Phase 2 Demonstrator

The ATLAS Tile Calorimeter phase 2 upgrade demonstrator aims at installing a hybrid on-detector electronic system replacing 1-4 adjacent TileCal drawers in ATLAS starting end of phase 0, combining a fully functional phase 2 system with circuitry making it compatible with the present system. We are r...

Descripción completa

Detalles Bibliográficos
Autores principales: Muschter, S, Anderson, K, Bohm, C, Eriksson, D, Oreglia, M, Tang, F
Lenguaje:eng
Publicado: 2012
Materias:
Acceso en línea:http://cds.cern.ch/record/1478201
_version_ 1780925591173726208
author Muschter, S
Anderson, K
Bohm, C
Eriksson, D
Oreglia, M
Tang, F
author_facet Muschter, S
Anderson, K
Bohm, C
Eriksson, D
Oreglia, M
Tang, F
author_sort Muschter, S
collection CERN
description The ATLAS Tile Calorimeter phase 2 upgrade demonstrator aims at installing a hybrid on-detector electronic system replacing 1-4 adjacent TileCal drawers in ATLAS starting end of phase 0, combining a fully functional phase 2 system with circuitry making it compatible with the present system. We are reporting a second generation prototype link and controller board connecting the drawer to off-detector electronics in USA-15. The new boards main logic component is a XILINX Kintex7 FPGA connected to an 12x5 Gb/s AVAGO opto transmitter and a 4x10 Gb/s QSFP+ connector. One of the latter will be chosen for the final design
id cern-1478201
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2012
record_format invenio
spelling cern-14782012019-09-30T06:29:59Zhttp://cds.cern.ch/record/1478201engMuschter, SAnderson, KBohm, CEriksson, DOreglia, MTang, FDevelopment of a Readout Link Board for theTileCal Phase 2 DemonstratorDetectors and Experimental TechniquesThe ATLAS Tile Calorimeter phase 2 upgrade demonstrator aims at installing a hybrid on-detector electronic system replacing 1-4 adjacent TileCal drawers in ATLAS starting end of phase 0, combining a fully functional phase 2 system with circuitry making it compatible with the present system. We are reporting a second generation prototype link and controller board connecting the drawer to off-detector electronics in USA-15. The new boards main logic component is a XILINX Kintex7 FPGA connected to an 12x5 Gb/s AVAGO opto transmitter and a 4x10 Gb/s QSFP+ connector. One of the latter will be chosen for the final designATL-TILECAL-SLIDE-2012-525oai:cds.cern.ch:14782012012-09-15
spellingShingle Detectors and Experimental Techniques
Muschter, S
Anderson, K
Bohm, C
Eriksson, D
Oreglia, M
Tang, F
Development of a Readout Link Board for theTileCal Phase 2 Demonstrator
title Development of a Readout Link Board for theTileCal Phase 2 Demonstrator
title_full Development of a Readout Link Board for theTileCal Phase 2 Demonstrator
title_fullStr Development of a Readout Link Board for theTileCal Phase 2 Demonstrator
title_full_unstemmed Development of a Readout Link Board for theTileCal Phase 2 Demonstrator
title_short Development of a Readout Link Board for theTileCal Phase 2 Demonstrator
title_sort development of a readout link board for thetilecal phase 2 demonstrator
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/1478201
work_keys_str_mv AT muschters developmentofareadoutlinkboardforthetilecalphase2demonstrator
AT andersonk developmentofareadoutlinkboardforthetilecalphase2demonstrator
AT bohmc developmentofareadoutlinkboardforthetilecalphase2demonstrator
AT erikssond developmentofareadoutlinkboardforthetilecalphase2demonstrator
AT oregliam developmentofareadoutlinkboardforthetilecalphase2demonstrator
AT tangf developmentofareadoutlinkboardforthetilecalphase2demonstrator