Cargando…

CMS Technical Design Report for the Phase 1 Upgrade of the Hadron Calorimeter

This report describes the technical design and outlines the expected performance of the Phase 1 Upgrade of the CMS Hadron Calorimeters. The upgrade is designed to improve the performance of the calorimeters at high luminosity with large numbers of pileup events by increasing the depth-segmentation o...

Descripción completa

Detalles Bibliográficos
Autores principales: Mans, J, Anderson, J, Dahmes, B, de Barbaro, P, Freeman, J, Grassi, T, Hazen, E, Ruchti, R, Schimdt, I, Shaw, T, Tully, C, Whitmore, J, Yetkin, T
Lenguaje:eng
Publicado: 2012
Materias:
Acceso en línea:http://cds.cern.ch/record/1481837
_version_ 1780925981161160704
author Mans, J
Anderson, J
Dahmes, B
de Barbaro, P
Freeman, J
Grassi, T
Hazen, E
Mans, J
Ruchti, R
Schimdt, I
Shaw, T
Tully, C
Whitmore, J
Yetkin, T
author_facet Mans, J
Anderson, J
Dahmes, B
de Barbaro, P
Freeman, J
Grassi, T
Hazen, E
Mans, J
Ruchti, R
Schimdt, I
Shaw, T
Tully, C
Whitmore, J
Yetkin, T
author_sort Mans, J
collection CERN
description This report describes the technical design and outlines the expected performance of the Phase 1 Upgrade of the CMS Hadron Calorimeters. The upgrade is designed to improve the performance of the calorimeters at high luminosity with large numbers of pileup events by increasing the depth-segmentation of the calorimeter and providing new capabilities for anomalous background rejection. The photodetectors of the CMS Barrel and Endcap Hadron Calorimeters, currently hybrid photodiodes (HPDs), will be replaced by silicon photomultiplier (SiPM) devices. The single-channel phototubes of the Forward Hadron Calorimeter will be replaced by multi-anode phototubes operated in a dual-anode configuration. The readout electronics for all three calorimeter systems will also be replaced. A new charge-integrating ADC, the QIE10, with an integrated TDC will be used along with a 4.8 Gbps data-link. The off-detector electronics will also be substantially upgraded to handle higher data volumes and improve the information sent to the calorimeter trigger system. The expected performance of these upgrades is discussed, including a detailed study of several Higgs and SUSY analyses. The planning for the implementation of this upgrade is presented, including construction, testing, and installation.
id cern-1481837
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2012
record_format invenio
spelling cern-14818372022-05-06T08:10:50Zhttp://cds.cern.ch/record/1481837engMans, JAnderson, JDahmes, Bde Barbaro, PFreeman, JGrassi, THazen, EMans, JRuchti, RSchimdt, IShaw, TTully, CWhitmore, JYetkin, TCMS Technical Design Report for the Phase 1 Upgrade of the Hadron CalorimeterDetectors and Experimental TechniquesThis report describes the technical design and outlines the expected performance of the Phase 1 Upgrade of the CMS Hadron Calorimeters. The upgrade is designed to improve the performance of the calorimeters at high luminosity with large numbers of pileup events by increasing the depth-segmentation of the calorimeter and providing new capabilities for anomalous background rejection. The photodetectors of the CMS Barrel and Endcap Hadron Calorimeters, currently hybrid photodiodes (HPDs), will be replaced by silicon photomultiplier (SiPM) devices. The single-channel phototubes of the Forward Hadron Calorimeter will be replaced by multi-anode phototubes operated in a dual-anode configuration. The readout electronics for all three calorimeter systems will also be replaced. A new charge-integrating ADC, the QIE10, with an integrated TDC will be used along with a 4.8 Gbps data-link. The off-detector electronics will also be substantially upgraded to handle higher data volumes and improve the information sent to the calorimeter trigger system. The expected performance of these upgrades is discussed, including a detailed study of several Higgs and SUSY analyses. The planning for the implementation of this upgrade is presented, including construction, testing, and installation.CERN-LHCC-2012-015CMS-TDR-10oai:cds.cern.ch:14818372012-09-27
spellingShingle Detectors and Experimental Techniques
Mans, J
Anderson, J
Dahmes, B
de Barbaro, P
Freeman, J
Grassi, T
Hazen, E
Mans, J
Ruchti, R
Schimdt, I
Shaw, T
Tully, C
Whitmore, J
Yetkin, T
CMS Technical Design Report for the Phase 1 Upgrade of the Hadron Calorimeter
title CMS Technical Design Report for the Phase 1 Upgrade of the Hadron Calorimeter
title_full CMS Technical Design Report for the Phase 1 Upgrade of the Hadron Calorimeter
title_fullStr CMS Technical Design Report for the Phase 1 Upgrade of the Hadron Calorimeter
title_full_unstemmed CMS Technical Design Report for the Phase 1 Upgrade of the Hadron Calorimeter
title_short CMS Technical Design Report for the Phase 1 Upgrade of the Hadron Calorimeter
title_sort cms technical design report for the phase 1 upgrade of the hadron calorimeter
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/1481837
work_keys_str_mv AT mansj cmstechnicaldesignreportforthephase1upgradeofthehadroncalorimeter
AT andersonj cmstechnicaldesignreportforthephase1upgradeofthehadroncalorimeter
AT dahmesb cmstechnicaldesignreportforthephase1upgradeofthehadroncalorimeter
AT debarbarop cmstechnicaldesignreportforthephase1upgradeofthehadroncalorimeter
AT freemanj cmstechnicaldesignreportforthephase1upgradeofthehadroncalorimeter
AT grassit cmstechnicaldesignreportforthephase1upgradeofthehadroncalorimeter
AT hazene cmstechnicaldesignreportforthephase1upgradeofthehadroncalorimeter
AT mansj cmstechnicaldesignreportforthephase1upgradeofthehadroncalorimeter
AT ruchtir cmstechnicaldesignreportforthephase1upgradeofthehadroncalorimeter
AT schimdti cmstechnicaldesignreportforthephase1upgradeofthehadroncalorimeter
AT shawt cmstechnicaldesignreportforthephase1upgradeofthehadroncalorimeter
AT tullyc cmstechnicaldesignreportforthephase1upgradeofthehadroncalorimeter
AT whitmorej cmstechnicaldesignreportforthephase1upgradeofthehadroncalorimeter
AT yetkint cmstechnicaldesignreportforthephase1upgradeofthehadroncalorimeter