Cargando…
CMS Technical Design Report for the Phase 1 Upgrade of the Hadron Calorimeter
This report describes the technical design and outlines the expected performance of the Phase 1 Upgrade of the CMS Hadron Calorimeters. The upgrade is designed to improve the performance of the calorimeters at high luminosity with large numbers of pileup events by increasing the depth-segmentation o...
Autores principales: | , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2012
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1481837 |
_version_ | 1780925981161160704 |
---|---|
author | Mans, J Anderson, J Dahmes, B de Barbaro, P Freeman, J Grassi, T Hazen, E Mans, J Ruchti, R Schimdt, I Shaw, T Tully, C Whitmore, J Yetkin, T |
author_facet | Mans, J Anderson, J Dahmes, B de Barbaro, P Freeman, J Grassi, T Hazen, E Mans, J Ruchti, R Schimdt, I Shaw, T Tully, C Whitmore, J Yetkin, T |
author_sort | Mans, J |
collection | CERN |
description | This report describes the technical design and outlines the expected performance of the Phase 1 Upgrade of the CMS Hadron Calorimeters. The upgrade is designed to improve the performance of the calorimeters at high luminosity with large numbers of pileup events by increasing the depth-segmentation of the calorimeter and providing new capabilities for anomalous background rejection. The photodetectors of the CMS Barrel and Endcap Hadron Calorimeters, currently hybrid photodiodes (HPDs), will be replaced by silicon photomultiplier (SiPM) devices. The single-channel phototubes of the Forward Hadron Calorimeter will be replaced by multi-anode phototubes operated in a dual-anode configuration. The readout electronics for all three calorimeter systems will also be replaced. A new charge-integrating ADC, the QIE10, with an integrated TDC will be used along with a 4.8 Gbps data-link. The off-detector electronics will also be substantially upgraded to handle higher data volumes and improve the information sent to the calorimeter trigger system. The expected performance of these upgrades is discussed, including a detailed study of several Higgs and SUSY analyses. The planning for the implementation of this upgrade is presented, including construction, testing, and installation. |
id | cern-1481837 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2012 |
record_format | invenio |
spelling | cern-14818372022-05-06T08:10:50Zhttp://cds.cern.ch/record/1481837engMans, JAnderson, JDahmes, Bde Barbaro, PFreeman, JGrassi, THazen, EMans, JRuchti, RSchimdt, IShaw, TTully, CWhitmore, JYetkin, TCMS Technical Design Report for the Phase 1 Upgrade of the Hadron CalorimeterDetectors and Experimental TechniquesThis report describes the technical design and outlines the expected performance of the Phase 1 Upgrade of the CMS Hadron Calorimeters. The upgrade is designed to improve the performance of the calorimeters at high luminosity with large numbers of pileup events by increasing the depth-segmentation of the calorimeter and providing new capabilities for anomalous background rejection. The photodetectors of the CMS Barrel and Endcap Hadron Calorimeters, currently hybrid photodiodes (HPDs), will be replaced by silicon photomultiplier (SiPM) devices. The single-channel phototubes of the Forward Hadron Calorimeter will be replaced by multi-anode phototubes operated in a dual-anode configuration. The readout electronics for all three calorimeter systems will also be replaced. A new charge-integrating ADC, the QIE10, with an integrated TDC will be used along with a 4.8 Gbps data-link. The off-detector electronics will also be substantially upgraded to handle higher data volumes and improve the information sent to the calorimeter trigger system. The expected performance of these upgrades is discussed, including a detailed study of several Higgs and SUSY analyses. The planning for the implementation of this upgrade is presented, including construction, testing, and installation.CERN-LHCC-2012-015CMS-TDR-10oai:cds.cern.ch:14818372012-09-27 |
spellingShingle | Detectors and Experimental Techniques Mans, J Anderson, J Dahmes, B de Barbaro, P Freeman, J Grassi, T Hazen, E Mans, J Ruchti, R Schimdt, I Shaw, T Tully, C Whitmore, J Yetkin, T CMS Technical Design Report for the Phase 1 Upgrade of the Hadron Calorimeter |
title | CMS Technical Design Report for the Phase 1 Upgrade of the Hadron Calorimeter |
title_full | CMS Technical Design Report for the Phase 1 Upgrade of the Hadron Calorimeter |
title_fullStr | CMS Technical Design Report for the Phase 1 Upgrade of the Hadron Calorimeter |
title_full_unstemmed | CMS Technical Design Report for the Phase 1 Upgrade of the Hadron Calorimeter |
title_short | CMS Technical Design Report for the Phase 1 Upgrade of the Hadron Calorimeter |
title_sort | cms technical design report for the phase 1 upgrade of the hadron calorimeter |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/1481837 |
work_keys_str_mv | AT mansj cmstechnicaldesignreportforthephase1upgradeofthehadroncalorimeter AT andersonj cmstechnicaldesignreportforthephase1upgradeofthehadroncalorimeter AT dahmesb cmstechnicaldesignreportforthephase1upgradeofthehadroncalorimeter AT debarbarop cmstechnicaldesignreportforthephase1upgradeofthehadroncalorimeter AT freemanj cmstechnicaldesignreportforthephase1upgradeofthehadroncalorimeter AT grassit cmstechnicaldesignreportforthephase1upgradeofthehadroncalorimeter AT hazene cmstechnicaldesignreportforthephase1upgradeofthehadroncalorimeter AT mansj cmstechnicaldesignreportforthephase1upgradeofthehadroncalorimeter AT ruchtir cmstechnicaldesignreportforthephase1upgradeofthehadroncalorimeter AT schimdti cmstechnicaldesignreportforthephase1upgradeofthehadroncalorimeter AT shawt cmstechnicaldesignreportforthephase1upgradeofthehadroncalorimeter AT tullyc cmstechnicaldesignreportforthephase1upgradeofthehadroncalorimeter AT whitmorej cmstechnicaldesignreportforthephase1upgradeofthehadroncalorimeter AT yetkint cmstechnicaldesignreportforthephase1upgradeofthehadroncalorimeter |