Cargando…
Injection MD
This note summarizes the results obtained at injection during the 2nd MD block and the floating MD block in July. Highlights are presented for injection in the LHC with the Q20 SPS optics, influence of the supercycle and injection with 25 ns bunch spacing. Beams were successfully injected into the L...
Autores principales: | , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2012
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1491672 |
_version_ | 1780926433164525568 |
---|---|
author | Bartmann, W Bartosik, H Bracco, C Drosdal, L Gianfelice, E Goddard, B Kain, V Papaphilippou, Y Vanbavinckhove, G |
author_facet | Bartmann, W Bartosik, H Bracco, C Drosdal, L Gianfelice, E Goddard, B Kain, V Papaphilippou, Y Vanbavinckhove, G |
author_sort | Bartmann, W |
collection | CERN |
description | This note summarizes the results obtained at injection during the 2nd MD block and the floating MD block in July. Highlights are presented for injection in the LHC with the Q20 SPS optics, influence of the supercycle and injection with 25 ns bunch spacing. Beams were successfully injected into the LHC using the Q20 optics [1, 3]. Small corrections were needed to steer the beam in the transfer lines. Dispersion measurements were conducted for both beams. The horizontal normalized dispersion in TI2 was a factor 2 smaller for Q20 with respect to Q26, for TI8 on the other hand the opposite was observed. The results for injection loss dependency on super cycle composition show only a small increase in losses for beam 2. The losses observed must therefore mainly come from other sources such as shot-by-shot stability or quality of scraping. For the injection with 25 ns bunch spacing bunches were injected for both beams. For B1 up to the maximum of 288 bunches. For B2 on the other only up to 144 bunches were injected, due to the higher number of voltage breakdowns for a P8 injection kicker magnet. There is enough margin for increasing the bunch intensity and at the same time keeping losses below 30% for operational flexibility. |
id | cern-1491672 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2012 |
record_format | invenio |
spelling | cern-14916722019-09-30T06:29:59Zhttp://cds.cern.ch/record/1491672engBartmann, WBartosik, HBracco, CDrosdal, LGianfelice, EGoddard, BKain, VPapaphilippou, YVanbavinckhove, GInjection MDAccelerators and Storage RingsThis note summarizes the results obtained at injection during the 2nd MD block and the floating MD block in July. Highlights are presented for injection in the LHC with the Q20 SPS optics, influence of the supercycle and injection with 25 ns bunch spacing. Beams were successfully injected into the LHC using the Q20 optics [1, 3]. Small corrections were needed to steer the beam in the transfer lines. Dispersion measurements were conducted for both beams. The horizontal normalized dispersion in TI2 was a factor 2 smaller for Q20 with respect to Q26, for TI8 on the other hand the opposite was observed. The results for injection loss dependency on super cycle composition show only a small increase in losses for beam 2. The losses observed must therefore mainly come from other sources such as shot-by-shot stability or quality of scraping. For the injection with 25 ns bunch spacing bunches were injected for both beams. For B1 up to the maximum of 288 bunches. For B2 on the other only up to 144 bunches were injected, due to the higher number of voltage breakdowns for a P8 injection kicker magnet. There is enough margin for increasing the bunch intensity and at the same time keeping losses below 30% for operational flexibility.CERN-ATS-Note-2012-090 MDoai:cds.cern.ch:14916722012-11-05 |
spellingShingle | Accelerators and Storage Rings Bartmann, W Bartosik, H Bracco, C Drosdal, L Gianfelice, E Goddard, B Kain, V Papaphilippou, Y Vanbavinckhove, G Injection MD |
title | Injection MD |
title_full | Injection MD |
title_fullStr | Injection MD |
title_full_unstemmed | Injection MD |
title_short | Injection MD |
title_sort | injection md |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/1491672 |
work_keys_str_mv | AT bartmannw injectionmd AT bartosikh injectionmd AT braccoc injectionmd AT drosdall injectionmd AT gianfelicee injectionmd AT goddardb injectionmd AT kainv injectionmd AT papaphilippouy injectionmd AT vanbavinckhoveg injectionmd |