Cargando…
The CMS ECAL Barrel HV system
The CMS electro-magnetic calorimeter comprises 75848 scintillating lead tungstate crystals. 61200 crystals are contained in the ECAL Barrel section and these are readout by avalanche photodiodes (APD) with internal gain. The APD gain strongly depends on the bias voltage that, for a gain G=50, is aro...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2012
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1494501 |
_version_ | 1780926551853891584 |
---|---|
author | Bartoloni, Alessandro |
author_facet | Bartoloni, Alessandro |
author_sort | Bartoloni, Alessandro |
collection | CERN |
description | The CMS electro-magnetic calorimeter comprises 75848 scintillating lead tungstate crystals. 61200 crystals are contained in the ECAL Barrel section and these are readout by avalanche photodiodes (APD) with internal gain. The APD gain strongly depends on the bias voltage that, for a gain G=50, is around 400 V. In order to match the requirements for gain stability, the power supply voltage must be stable to within 0.01\%. In this talk we describe our experience with the installed Barrel HV power supply system which has been used for data taking at the LHC since 2008. |
id | cern-1494501 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2012 |
record_format | invenio |
spelling | cern-14945012019-09-30T06:29:59Zhttp://cds.cern.ch/record/1494501engBartoloni, AlessandroThe CMS ECAL Barrel HV systemDetectors and Experimental TechniquesThe CMS electro-magnetic calorimeter comprises 75848 scintillating lead tungstate crystals. 61200 crystals are contained in the ECAL Barrel section and these are readout by avalanche photodiodes (APD) with internal gain. The APD gain strongly depends on the bias voltage that, for a gain G=50, is around 400 V. In order to match the requirements for gain stability, the power supply voltage must be stable to within 0.01\%. In this talk we describe our experience with the installed Barrel HV power supply system which has been used for data taking at the LHC since 2008.CMS-CR-2012-285oai:cds.cern.ch:14945012012-10-25 |
spellingShingle | Detectors and Experimental Techniques Bartoloni, Alessandro The CMS ECAL Barrel HV system |
title | The CMS ECAL Barrel HV system |
title_full | The CMS ECAL Barrel HV system |
title_fullStr | The CMS ECAL Barrel HV system |
title_full_unstemmed | The CMS ECAL Barrel HV system |
title_short | The CMS ECAL Barrel HV system |
title_sort | cms ecal barrel hv system |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/1494501 |
work_keys_str_mv | AT bartolonialessandro thecmsecalbarrelhvsystem AT bartolonialessandro cmsecalbarrelhvsystem |