Cargando…
Characterization of a wide dynamic-range, radiation-tolerant charge-digitizer asic for monitoring of Beam losses
An Application Specific Integrated Circuit (ASIC) has been designed and fabricated to provide a compact solution to digitize current signals from ionization chambers and diamond detectors, employed as beam loss monitors at CERN and several other high energy physics facilities. The circuit topology h...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2012
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1495072 |
_version_ | 1780926574647836672 |
---|---|
author | Guido Venturini, G G Anghinolfi, F Dehning, B Kayal, M |
author_facet | Guido Venturini, G G Anghinolfi, F Dehning, B Kayal, M |
author_sort | Guido Venturini, G G |
collection | CERN |
description | An Application Specific Integrated Circuit (ASIC) has been designed and fabricated to provide a compact solution to digitize current signals from ionization chambers and diamond detectors, employed as beam loss monitors at CERN and several other high energy physics facilities. The circuit topology has been devised to accept positive and negative currents, to have a wide dynamic range (above 120 dB), withstand radiation levels over 10 Mrad and offer different modes of operation, covering a broad range of applications. Furthermore, an internal conversion reference is employed in the digitization, to provide an accurate absolute measurement. This paper discusses the detailed characterization of the first prototype: linearity, radiation tolerance and temperature dependence of the conversion, as well as implications and system-level considerations regarding its use for beam instrumentation applications in a high energy physics facility. |
id | cern-1495072 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2012 |
record_format | invenio |
spelling | cern-14950722019-09-30T06:29:59Zhttp://cds.cern.ch/record/1495072engGuido Venturini, G GAnghinolfi, FDehning, BKayal, MCharacterization of a wide dynamic-range, radiation-tolerant charge-digitizer asic for monitoring of Beam lossesAccelerators and Storage RingsAn Application Specific Integrated Circuit (ASIC) has been designed and fabricated to provide a compact solution to digitize current signals from ionization chambers and diamond detectors, employed as beam loss monitors at CERN and several other high energy physics facilities. The circuit topology has been devised to accept positive and negative currents, to have a wide dynamic range (above 120 dB), withstand radiation levels over 10 Mrad and offer different modes of operation, covering a broad range of applications. Furthermore, an internal conversion reference is employed in the digitization, to provide an accurate absolute measurement. This paper discusses the detailed characterization of the first prototype: linearity, radiation tolerance and temperature dependence of the conversion, as well as implications and system-level considerations regarding its use for beam instrumentation applications in a high energy physics facility.CERN-ATS-2012-281oai:cds.cern.ch:14950722012-10-01 |
spellingShingle | Accelerators and Storage Rings Guido Venturini, G G Anghinolfi, F Dehning, B Kayal, M Characterization of a wide dynamic-range, radiation-tolerant charge-digitizer asic for monitoring of Beam losses |
title | Characterization of a wide dynamic-range, radiation-tolerant charge-digitizer asic for monitoring of Beam losses |
title_full | Characterization of a wide dynamic-range, radiation-tolerant charge-digitizer asic for monitoring of Beam losses |
title_fullStr | Characterization of a wide dynamic-range, radiation-tolerant charge-digitizer asic for monitoring of Beam losses |
title_full_unstemmed | Characterization of a wide dynamic-range, radiation-tolerant charge-digitizer asic for monitoring of Beam losses |
title_short | Characterization of a wide dynamic-range, radiation-tolerant charge-digitizer asic for monitoring of Beam losses |
title_sort | characterization of a wide dynamic-range, radiation-tolerant charge-digitizer asic for monitoring of beam losses |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/1495072 |
work_keys_str_mv | AT guidoventurinigg characterizationofawidedynamicrangeradiationtolerantchargedigitizerasicformonitoringofbeamlosses AT anghinolfif characterizationofawidedynamicrangeradiationtolerantchargedigitizerasicformonitoringofbeamlosses AT dehningb characterizationofawidedynamicrangeradiationtolerantchargedigitizerasicformonitoringofbeamlosses AT kayalm characterizationofawidedynamicrangeradiationtolerantchargedigitizerasicformonitoringofbeamlosses |