Cargando…
A novel High-Voltage System for a triple GEM detector
A novel High-Voltage System for a triple GEM detector has been designed and realized in Frascati within the LHCb muon detector framework. The system is built with seven floating power supply, with a maximum of 1200 V each, and controlled via CANbus, for voltage settings and monitoring. Several HV mo...
Autores principales: | , , |
---|---|
Formato: | info:eu-repo/semantics/article |
Lenguaje: | eng |
Publicado: |
Nucl. Instrum. Methods Phys. Res., A
2007
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1496409 |
_version_ | 1780926643751092224 |
---|---|
author | Corradi, Giovanni Murtas, Fabrizio Tagnani, Diego |
author_facet | Corradi, Giovanni Murtas, Fabrizio Tagnani, Diego |
author_sort | Corradi, Giovanni |
collection | CERN |
description | A novel High-Voltage System for a triple GEM detector has been designed and realized in Frascati within the LHCb muon detector framework. The system is built with seven floating power supply, with a maximum of 1200 V each, and controlled via CANbus, for voltage settings and monitoring. Several HV modules can be installed in a nano-ammeter mainframe already developed in Frascati, realizing a HV crate able to supply up to 24 triple GEM chambers with a 1 nA resolution monitoring system. |
format | info:eu-repo/semantics/article |
id | cern-1496409 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2007 |
publisher | Nucl. Instrum. Methods Phys. Res., A |
record_format | invenio |
spelling | cern-14964092019-09-30T06:29:59Z http://cds.cern.ch/record/1496409 eng Corradi, Giovanni Murtas, Fabrizio Tagnani, Diego A novel High-Voltage System for a triple GEM detector Detectors and Experimental Techniques A novel High-Voltage System for a triple GEM detector has been designed and realized in Frascati within the LHCb muon detector framework. The system is built with seven floating power supply, with a maximum of 1200 V each, and controlled via CANbus, for voltage settings and monitoring. Several HV modules can be installed in a nano-ammeter mainframe already developed in Frascati, realizing a HV crate able to supply up to 24 triple GEM chambers with a 1 nA resolution monitoring system. info:eu-repo/grantAgreement/EC/FP7/289198 info:eu-repo/semantics/openAccess Education Level info:eu-repo/semantics/article http://cds.cern.ch/record/1496409 Nucl. Instrum. Methods Phys. Res., A info:doi/10.1016/j.nima.2006.10.166 Nucl. Instrum. Methods Phys. Res., A, 1 (2007) pp. 96-97 2007 |
spellingShingle | Detectors and Experimental Techniques Corradi, Giovanni Murtas, Fabrizio Tagnani, Diego A novel High-Voltage System for a triple GEM detector |
title | A novel High-Voltage System for a triple GEM detector |
title_full | A novel High-Voltage System for a triple GEM detector |
title_fullStr | A novel High-Voltage System for a triple GEM detector |
title_full_unstemmed | A novel High-Voltage System for a triple GEM detector |
title_short | A novel High-Voltage System for a triple GEM detector |
title_sort | novel high-voltage system for a triple gem detector |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/1496409 http://cds.cern.ch/record/1496409 |
work_keys_str_mv | AT corradigiovanni anovelhighvoltagesystemforatriplegemdetector AT murtasfabrizio anovelhighvoltagesystemforatriplegemdetector AT tagnanidiego anovelhighvoltagesystemforatriplegemdetector AT corradigiovanni novelhighvoltagesystemforatriplegemdetector AT murtasfabrizio novelhighvoltagesystemforatriplegemdetector AT tagnanidiego novelhighvoltagesystemforatriplegemdetector |