Cargando…

A DC-DC Conversion Powering Scheme for the CMS Phase-1 Pixel Upgrade

The CMS pixel detector was designed for a nominal instantaneous LHC luminosity of $1\cdot 10^{34}$\,cm$^{-2}$s$^{-1}$. During Phase-1 of the LHC upgrade, the instantaneous luminosity will be increased to about twice this value. To preserve the excellent performance of the pixel detector despite the...

Descripción completa

Detalles Bibliográficos
Autores principales: Feld, Lutz Werner, Martin Fleck, Marcel Friedrichs, Richard Hensch, Karpinski, Waclaw, Klein, Katja, Sammet, Jan Domenik, Wlochal, Michael
Lenguaje:eng
Publicado: 2012
Materias:
Acceso en línea:http://cds.cern.ch/record/1498686
_version_ 1780926731546263552
author Feld, Lutz Werner
Martin Fleck
Marcel Friedrichs
Richard Hensch
Karpinski, Waclaw
Klein, Katja
Sammet, Jan Domenik
Wlochal, Michael
author_facet Feld, Lutz Werner
Martin Fleck
Marcel Friedrichs
Richard Hensch
Karpinski, Waclaw
Klein, Katja
Sammet, Jan Domenik
Wlochal, Michael
author_sort Feld, Lutz Werner
collection CERN
description The CMS pixel detector was designed for a nominal instantaneous LHC luminosity of $1\cdot 10^{34}$\,cm$^{-2}$s$^{-1}$. During Phase-1 of the LHC upgrade, the instantaneous luminosity will be increased to about twice this value. To preserve the excellent performance of the pixel detector despite the increase in particle rates and track densities, the CMS Collaboration foresees the exchange of its pixel detector in the shutdown 2016/2017. The new pixel detector will be improved in many respects, and will comprise twice the number of readout channels. A powering scheme based on DC-DC conversion will be adopted, which will enable the provision of the required power with the present cable plant. \\ The powering scheme of the CMS pixel detector will be described, and the performance of prototype DC-DC buck converters will be presented, including power efficiency, system tests with DC-DC converters and pixel modules, thermal management, reliability at low temperature, and studies of potential frequency locking between DC-DC converters.
id cern-1498686
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2012
record_format invenio
spelling cern-14986862019-09-30T06:29:59Zhttp://cds.cern.ch/record/1498686engFeld, Lutz WernerMartin FleckMarcel FriedrichsRichard HenschKarpinski, WaclawKlein, KatjaSammet, Jan DomenikWlochal, MichaelA DC-DC Conversion Powering Scheme for the CMS Phase-1 Pixel UpgradeDetectors and Experimental TechniquesThe CMS pixel detector was designed for a nominal instantaneous LHC luminosity of $1\cdot 10^{34}$\,cm$^{-2}$s$^{-1}$. During Phase-1 of the LHC upgrade, the instantaneous luminosity will be increased to about twice this value. To preserve the excellent performance of the pixel detector despite the increase in particle rates and track densities, the CMS Collaboration foresees the exchange of its pixel detector in the shutdown 2016/2017. The new pixel detector will be improved in many respects, and will comprise twice the number of readout channels. A powering scheme based on DC-DC conversion will be adopted, which will enable the provision of the required power with the present cable plant. \\ The powering scheme of the CMS pixel detector will be described, and the performance of prototype DC-DC buck converters will be presented, including power efficiency, system tests with DC-DC converters and pixel modules, thermal management, reliability at low temperature, and studies of potential frequency locking between DC-DC converters.CMS-CR-2012-372oai:cds.cern.ch:14986862012-12-07
spellingShingle Detectors and Experimental Techniques
Feld, Lutz Werner
Martin Fleck
Marcel Friedrichs
Richard Hensch
Karpinski, Waclaw
Klein, Katja
Sammet, Jan Domenik
Wlochal, Michael
A DC-DC Conversion Powering Scheme for the CMS Phase-1 Pixel Upgrade
title A DC-DC Conversion Powering Scheme for the CMS Phase-1 Pixel Upgrade
title_full A DC-DC Conversion Powering Scheme for the CMS Phase-1 Pixel Upgrade
title_fullStr A DC-DC Conversion Powering Scheme for the CMS Phase-1 Pixel Upgrade
title_full_unstemmed A DC-DC Conversion Powering Scheme for the CMS Phase-1 Pixel Upgrade
title_short A DC-DC Conversion Powering Scheme for the CMS Phase-1 Pixel Upgrade
title_sort dc-dc conversion powering scheme for the cms phase-1 pixel upgrade
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/1498686
work_keys_str_mv AT feldlutzwerner adcdcconversionpoweringschemeforthecmsphase1pixelupgrade
AT martinfleck adcdcconversionpoweringschemeforthecmsphase1pixelupgrade
AT marcelfriedrichs adcdcconversionpoweringschemeforthecmsphase1pixelupgrade
AT richardhensch adcdcconversionpoweringschemeforthecmsphase1pixelupgrade
AT karpinskiwaclaw adcdcconversionpoweringschemeforthecmsphase1pixelupgrade
AT kleinkatja adcdcconversionpoweringschemeforthecmsphase1pixelupgrade
AT sammetjandomenik adcdcconversionpoweringschemeforthecmsphase1pixelupgrade
AT wlochalmichael adcdcconversionpoweringschemeforthecmsphase1pixelupgrade
AT feldlutzwerner dcdcconversionpoweringschemeforthecmsphase1pixelupgrade
AT martinfleck dcdcconversionpoweringschemeforthecmsphase1pixelupgrade
AT marcelfriedrichs dcdcconversionpoweringschemeforthecmsphase1pixelupgrade
AT richardhensch dcdcconversionpoweringschemeforthecmsphase1pixelupgrade
AT karpinskiwaclaw dcdcconversionpoweringschemeforthecmsphase1pixelupgrade
AT kleinkatja dcdcconversionpoweringschemeforthecmsphase1pixelupgrade
AT sammetjandomenik dcdcconversionpoweringschemeforthecmsphase1pixelupgrade
AT wlochalmichael dcdcconversionpoweringschemeforthecmsphase1pixelupgrade