Cargando…

Fast readout of the COMPASS RICH CsI-MWPC chambers

A new readout system for CsI-coated MWPCs, used in the COMPASS RICH detector, has been proposed and tested in nominal high-rate conditions. It is based on the APV25-S1 analog sampling chip, and will replace the Gassiplex chip readout used up to now. The APV chip, originally designed for silicon micr...

Descripción completa

Detalles Bibliográficos
Autores principales: Abbon, P, Delagnes, E, Deschampbs, H, Kunne, F, Gerasimov, S, Ketzer, B, Konorov, I, Kravtchuk, N, Magnon, A, Neyret, D, Panebianco, S, Paul, S, Rebourgeard, P, Tessaroto, F
Lenguaje:eng
Publicado: 2006
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2006.05.118
http://cds.cern.ch/record/1500061
_version_ 1780926834119016448
author Abbon, P
Delagnes, E
Deschampbs, H
Kunne, F
Gerasimov, S
Ketzer, B
Konorov, I
Kravtchuk, N
Magnon, A
Neyret, D
Panebianco, S
Paul, S
Rebourgeard, P
Tessaroto, F
author_facet Abbon, P
Delagnes, E
Deschampbs, H
Kunne, F
Gerasimov, S
Ketzer, B
Konorov, I
Kravtchuk, N
Magnon, A
Neyret, D
Panebianco, S
Paul, S
Rebourgeard, P
Tessaroto, F
author_sort Abbon, P
collection CERN
description A new readout system for CsI-coated MWPCs, used in the COMPASS RICH detector, has been proposed and tested in nominal high-rate conditions. It is based on the APV25-S1 analog sampling chip, and will replace the Gassiplex chip readout used up to now. The APV chip, originally designed for silicon microstrip detectors, is shown to perform well even with “slow” signals from a MWPC, keeping a signal-to-noise ratio of 9. For every trigger the system reads three consecutive in-time samples, thus allowing to extract information on the signal shape and its timing. The effective time window is reduced from ∼3 μs for the Gassiplex to below 400 ns for the APV25-S1 chip, reducing pile-up events at high particle rate. A significant improvement of the signal-to-background ratio by a factor 5–6 with respect to the original readout has been measured in the central region of the RICH detector. Due to its pipelined architecture, the new readout system also considerably reduces the dead time per event, allowing efficient data taking at higher trigger rate.
id cern-1500061
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2006
record_format invenio
spelling cern-15000612019-09-30T06:29:59Zdoi:10.1016/j.nima.2006.05.118http://cds.cern.ch/record/1500061engAbbon, PDelagnes, EDeschampbs, HKunne, FGerasimov, SKetzer, BKonorov, IKravtchuk, NMagnon, ANeyret, DPanebianco, SPaul, SRebourgeard, PTessaroto, FFast readout of the COMPASS RICH CsI-MWPC chambersParticle Physics - ExperimentA new readout system for CsI-coated MWPCs, used in the COMPASS RICH detector, has been proposed and tested in nominal high-rate conditions. It is based on the APV25-S1 analog sampling chip, and will replace the Gassiplex chip readout used up to now. The APV chip, originally designed for silicon microstrip detectors, is shown to perform well even with “slow” signals from a MWPC, keeping a signal-to-noise ratio of 9. For every trigger the system reads three consecutive in-time samples, thus allowing to extract information on the signal shape and its timing. The effective time window is reduced from ∼3 μs for the Gassiplex to below 400 ns for the APV25-S1 chip, reducing pile-up events at high particle rate. A significant improvement of the signal-to-background ratio by a factor 5–6 with respect to the original readout has been measured in the central region of the RICH detector. Due to its pipelined architecture, the new readout system also considerably reduces the dead time per event, allowing efficient data taking at higher trigger rate.oai:cds.cern.ch:15000612006
spellingShingle Particle Physics - Experiment
Abbon, P
Delagnes, E
Deschampbs, H
Kunne, F
Gerasimov, S
Ketzer, B
Konorov, I
Kravtchuk, N
Magnon, A
Neyret, D
Panebianco, S
Paul, S
Rebourgeard, P
Tessaroto, F
Fast readout of the COMPASS RICH CsI-MWPC chambers
title Fast readout of the COMPASS RICH CsI-MWPC chambers
title_full Fast readout of the COMPASS RICH CsI-MWPC chambers
title_fullStr Fast readout of the COMPASS RICH CsI-MWPC chambers
title_full_unstemmed Fast readout of the COMPASS RICH CsI-MWPC chambers
title_short Fast readout of the COMPASS RICH CsI-MWPC chambers
title_sort fast readout of the compass rich csi-mwpc chambers
topic Particle Physics - Experiment
url https://dx.doi.org/10.1016/j.nima.2006.05.118
http://cds.cern.ch/record/1500061
work_keys_str_mv AT abbonp fastreadoutofthecompassrichcsimwpcchambers
AT delagnese fastreadoutofthecompassrichcsimwpcchambers
AT deschampbsh fastreadoutofthecompassrichcsimwpcchambers
AT kunnef fastreadoutofthecompassrichcsimwpcchambers
AT gerasimovs fastreadoutofthecompassrichcsimwpcchambers
AT ketzerb fastreadoutofthecompassrichcsimwpcchambers
AT konorovi fastreadoutofthecompassrichcsimwpcchambers
AT kravtchukn fastreadoutofthecompassrichcsimwpcchambers
AT magnona fastreadoutofthecompassrichcsimwpcchambers
AT neyretd fastreadoutofthecompassrichcsimwpcchambers
AT panebiancos fastreadoutofthecompassrichcsimwpcchambers
AT pauls fastreadoutofthecompassrichcsimwpcchambers
AT rebourgeardp fastreadoutofthecompassrichcsimwpcchambers
AT tessarotof fastreadoutofthecompassrichcsimwpcchambers