LINAC4 is part of the CERN Large Hadron Collider injector chain upgrade (LIU) and will accelerate H- ions from 45 keV to 160 MeV, it will be the rst step of the upgrade with the replacement of LINAC2 in 2018. In order to measure beam proles along the LINAC, several SEM grid and wire beam scanner (WS...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2013
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1503551 |
_version_ | 1780927130783186944 |
---|---|
author | Cheymol, Benjamin |
author_facet | Cheymol, Benjamin |
author_sort | Cheymol, Benjamin |
collection | CERN |
description | LINAC4 is part of the CERN Large Hadron Collider injector chain upgrade (LIU) and will accelerate H- ions from 45 keV to 160 MeV, it will be the rst step of the upgrade with the replacement of LINAC2 in 2018. In order to measure beam proles along the LINAC, several SEM grid and wire beam scanner (WS) monitors will be installed between the RF cavities from 50 MeV to 160 MeV. This thesis covers all monitor design aspects intended to cope with the required specications. In particular, the overall measurement robust- ness, accuracy and sensitivity must be satised for dierent commissioning and operational scenarios. The physics mechanisms generating the wire signals and the wire resistance to beam induced thermal loads have been considered in order to determine the most appropriate monitor design in terms of wire material and dimensions. In addition, for the commissioning phase, a movable diagnostics test bench will be used to adjust the machine parameters during dierent stages of installation. One of the main instruments on this movable bench is a transverse emittance me- ter. This thesis presents the dierent studies done for the mechanical design of the slit and for the estimation of the systematical error on the measurement due to space charge and multiple scattering. To complete this section, the rst results of the commissioning of the LINAC4 ions source and LEBT are presented, together with results form emittance measurement taken at the Spallation Neutron Source in Oak Ridge (Tennessee, USA). This last part ot the thesis presents dierent studies done for a beam proles and emittance measurements with a laser wire, with a large input from the SNS beam diagnostic group. |
id | cern-1503551 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2013 |
record_format | invenio |
spelling | cern-15035512021-07-30T13:54:53Zhttp://cds.cern.ch/record/1503551engCheymol, BenjaminDevelopment of beam transverse profile and emittance monitors for the CERN LINAC4Accelerators and Storage RingsLINAC4 is part of the CERN Large Hadron Collider injector chain upgrade (LIU) and will accelerate H- ions from 45 keV to 160 MeV, it will be the rst step of the upgrade with the replacement of LINAC2 in 2018. In order to measure beam proles along the LINAC, several SEM grid and wire beam scanner (WS) monitors will be installed between the RF cavities from 50 MeV to 160 MeV. This thesis covers all monitor design aspects intended to cope with the required specications. In particular, the overall measurement robust- ness, accuracy and sensitivity must be satised for dierent commissioning and operational scenarios. The physics mechanisms generating the wire signals and the wire resistance to beam induced thermal loads have been considered in order to determine the most appropriate monitor design in terms of wire material and dimensions. In addition, for the commissioning phase, a movable diagnostics test bench will be used to adjust the machine parameters during dierent stages of installation. One of the main instruments on this movable bench is a transverse emittance me- ter. This thesis presents the dierent studies done for the mechanical design of the slit and for the estimation of the systematical error on the measurement due to space charge and multiple scattering. To complete this section, the rst results of the commissioning of the LINAC4 ions source and LEBT are presented, together with results form emittance measurement taken at the Spallation Neutron Source in Oak Ridge (Tennessee, USA). This last part ot the thesis presents dierent studies done for a beam proles and emittance measurements with a laser wire, with a large input from the SNS beam diagnostic group.CERN-THESIS-2011-289oai:cds.cern.ch:15035512013-01-08T14:49:02Z |
spellingShingle | Accelerators and Storage Rings Cheymol, Benjamin Development of beam transverse profile and emittance monitors for the CERN LINAC4 |
title | Development of beam transverse profile and emittance monitors for the CERN LINAC4 |
title_full | Development of beam transverse profile and emittance monitors for the CERN LINAC4 |
title_fullStr | Development of beam transverse profile and emittance monitors for the CERN LINAC4 |
title_full_unstemmed | Development of beam transverse profile and emittance monitors for the CERN LINAC4 |
title_short | Development of beam transverse profile and emittance monitors for the CERN LINAC4 |
title_sort | development of beam transverse profile and emittance monitors for the cern linac4 |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/1503551 |
work_keys_str_mv | AT cheymolbenjamin developmentofbeamtransverseprofileandemittancemonitorsforthecernlinac4 |