Cargando…

Reference masses for precision mass spectrometry: design and implementation of a Pierce geometry to the cluster Ion source at ISOLTRAP

At the mass spectrometer ISOLTRAP carbon clusters ($^{12}$Cn, 1$\leqslant$n$\leqslant$25) are provided as reference masses, which are of particular importance in higher mass ranges (m $\geqslant$ 200u). In this mass range the measurlment uncertainty is increasingly dominated by the difference of the...

Descripción completa

Detalles Bibliográficos
Autor principal: Lommen, Jonathan
Lenguaje:eng
Publicado: 2013
Materias:
Acceso en línea:http://cds.cern.ch/record/1523784
_version_ 1780929253763710976
author Lommen, Jonathan
author_facet Lommen, Jonathan
author_sort Lommen, Jonathan
collection CERN
description At the mass spectrometer ISOLTRAP carbon clusters ($^{12}$Cn, 1$\leqslant$n$\leqslant$25) are provided as reference masses, which are of particular importance in higher mass ranges (m $\geqslant$ 200u). In this mass range the measurlment uncertainty is increasingly dominated by the difference of the reference mass and the mass of the ion of interest. Using carbon clusters instead of the common $^{133}$Cs ions, this difference decreases. The carbon clusters are produced in a laser ion source which has been improved in the frame of this thesis. The fluctuations of the count rate have been investigated as a function of the laser energy. Furthermore, the energy density at the target has been increased by implementation of a telescope into the laser beam line, which leads to a more narrow energy distribution of the ions. Through the exact adjustment of timing and length of a pulsed cavity an energy range with constant count rate could be selected. In order to provide ideal starting conditions during and after the laser ablation, a new extraction has been designed. The parts were manufactured according to technical drawings which have been produced. Moreover, by performing a precision mass measurement during an on-line run, the uncertainty of $^{208}$Fr was decreased almost one order of magnitude to less than 7 keV.
id cern-1523784
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2013
record_format invenio
spelling cern-15237842019-09-30T06:29:59Zhttp://cds.cern.ch/record/1523784engLommen, JonathanReference masses for precision mass spectrometry: design and implementation of a Pierce geometry to the cluster Ion source at ISOLTRAPNuclear Physics - ExperimentAt the mass spectrometer ISOLTRAP carbon clusters ($^{12}$Cn, 1$\leqslant$n$\leqslant$25) are provided as reference masses, which are of particular importance in higher mass ranges (m $\geqslant$ 200u). In this mass range the measurlment uncertainty is increasingly dominated by the difference of the reference mass and the mass of the ion of interest. Using carbon clusters instead of the common $^{133}$Cs ions, this difference decreases. The carbon clusters are produced in a laser ion source which has been improved in the frame of this thesis. The fluctuations of the count rate have been investigated as a function of the laser energy. Furthermore, the energy density at the target has been increased by implementation of a telescope into the laser beam line, which leads to a more narrow energy distribution of the ions. Through the exact adjustment of timing and length of a pulsed cavity an energy range with constant count rate could be selected. In order to provide ideal starting conditions during and after the laser ablation, a new extraction has been designed. The parts were manufactured according to technical drawings which have been produced. Moreover, by performing a precision mass measurement during an on-line run, the uncertainty of $^{208}$Fr was decreased almost one order of magnitude to less than 7 keV.CERN-THESIS-2011-310oai:cds.cern.ch:15237842013-03-07T12:31:09Z
spellingShingle Nuclear Physics - Experiment
Lommen, Jonathan
Reference masses for precision mass spectrometry: design and implementation of a Pierce geometry to the cluster Ion source at ISOLTRAP
title Reference masses for precision mass spectrometry: design and implementation of a Pierce geometry to the cluster Ion source at ISOLTRAP
title_full Reference masses for precision mass spectrometry: design and implementation of a Pierce geometry to the cluster Ion source at ISOLTRAP
title_fullStr Reference masses for precision mass spectrometry: design and implementation of a Pierce geometry to the cluster Ion source at ISOLTRAP
title_full_unstemmed Reference masses for precision mass spectrometry: design and implementation of a Pierce geometry to the cluster Ion source at ISOLTRAP
title_short Reference masses for precision mass spectrometry: design and implementation of a Pierce geometry to the cluster Ion source at ISOLTRAP
title_sort reference masses for precision mass spectrometry: design and implementation of a pierce geometry to the cluster ion source at isoltrap
topic Nuclear Physics - Experiment
url http://cds.cern.ch/record/1523784
work_keys_str_mv AT lommenjonathan referencemassesforprecisionmassspectrometrydesignandimplementationofapiercegeometrytotheclusterionsourceatisoltrap