Cargando…
A Study of Beam Position Diagnostics with Beam-excited Dipole Higher Order Modes using a Downconverter Test Electronics in Third Harmonic 3.9 GHz Superconducting Accelerating Cavities at FLASH
Beam-excited higher order modes (HOM) in accelerating cavities contain transverse beam position information. Previous studies have narrowed down three modal options for beam position diagnostics in the third harmonic 3.9 GHz cavities at FLASH. Localized modes in the beam pipes at approximately 4.1 G...
Autores principales: | , , , , , , , |
---|---|
Formato: | info:eu-repo/semantics/article |
Lenguaje: | eng |
Publicado: |
2012
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1550975 |
_version_ | 1780930218713677824 |
---|---|
author | Zhang, P Baboi, N Eddy, N Fellenz, B Jones, R M Lorbeer, B Wamsat, T Wendt, M |
author_facet | Zhang, P Baboi, N Eddy, N Fellenz, B Jones, R M Lorbeer, B Wamsat, T Wendt, M |
author_sort | Zhang, P |
collection | CERN |
description | Beam-excited higher order modes (HOM) in accelerating cavities contain transverse beam position information. Previous studies have narrowed down three modal options for beam position diagnostics in the third harmonic 3.9 GHz cavities at FLASH. Localized modes in the beam pipes at approximately 4.1 GHz and in the fifth cavity dipole band at approximately 9 GHz were found, that can provide a local measurement of the beam position. In contrast, propagating modes in the first and second dipole bands between 4.2 and 5.5 GHz can reach a better resolution. All the options were assessed with a specially designed test electronics built by Fermilab. The aim is to define a mode or spectral region suitable for the HOM electronics. Two data analysis techniques are used and compared in extracting beam position information from the dipole HOMs: direct linear regression and singular value decomposition. Current experiments suggest a resolution of 50 micron accuracy in predicting local beam position using modes in the fifth dipole band, and a global resolution of 20 micron over the complete module. Based on these results we decided to build a HOM electronics for the second dipole band and the fifth dipole band, so that we will have both high resolution measurements for the whole module, and localized measurements for individual cavity. The prototype electronics is being built by Fermilab and planned to be tested in FLASH by the end of 2012. |
format | info:eu-repo/semantics/article |
id | cern-1550975 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2012 |
record_format | invenio |
spelling | cern-15509752019-09-30T06:29:59Z http://cds.cern.ch/record/1550975 eng Zhang, P Baboi, N Eddy, N Fellenz, B Jones, R M Lorbeer, B Wamsat, T Wendt, M A Study of Beam Position Diagnostics with Beam-excited Dipole Higher Order Modes using a Downconverter Test Electronics in Third Harmonic 3.9 GHz Superconducting Accelerating Cavities at FLASH Accelerators and Storage Rings 10: SC RF technology for higher intensity proton accelerators and higher energy electron linacs Beam-excited higher order modes (HOM) in accelerating cavities contain transverse beam position information. Previous studies have narrowed down three modal options for beam position diagnostics in the third harmonic 3.9 GHz cavities at FLASH. Localized modes in the beam pipes at approximately 4.1 GHz and in the fifth cavity dipole band at approximately 9 GHz were found, that can provide a local measurement of the beam position. In contrast, propagating modes in the first and second dipole bands between 4.2 and 5.5 GHz can reach a better resolution. All the options were assessed with a specially designed test electronics built by Fermilab. The aim is to define a mode or spectral region suitable for the HOM electronics. Two data analysis techniques are used and compared in extracting beam position information from the dipole HOMs: direct linear regression and singular value decomposition. Current experiments suggest a resolution of 50 micron accuracy in predicting local beam position using modes in the fifth dipole band, and a global resolution of 20 micron over the complete module. Based on these results we decided to build a HOM electronics for the second dipole band and the fifth dipole band, so that we will have both high resolution measurements for the whole module, and localized measurements for individual cavity. The prototype electronics is being built by Fermilab and planned to be tested in FLASH by the end of 2012. info:eu-repo/grantAgreement/EC/FP7/227579 info:eu-repo/semantics/openAccess Education Level info:eu-repo/semantics/article http://cds.cern.ch/record/1550975 2012 |
spellingShingle | Accelerators and Storage Rings 10: SC RF technology for higher intensity proton accelerators and higher energy electron linacs Zhang, P Baboi, N Eddy, N Fellenz, B Jones, R M Lorbeer, B Wamsat, T Wendt, M A Study of Beam Position Diagnostics with Beam-excited Dipole Higher Order Modes using a Downconverter Test Electronics in Third Harmonic 3.9 GHz Superconducting Accelerating Cavities at FLASH |
title | A Study of Beam Position Diagnostics with Beam-excited Dipole Higher Order Modes using a Downconverter Test Electronics in Third Harmonic 3.9 GHz Superconducting Accelerating Cavities at FLASH |
title_full | A Study of Beam Position Diagnostics with Beam-excited Dipole Higher Order Modes using a Downconverter Test Electronics in Third Harmonic 3.9 GHz Superconducting Accelerating Cavities at FLASH |
title_fullStr | A Study of Beam Position Diagnostics with Beam-excited Dipole Higher Order Modes using a Downconverter Test Electronics in Third Harmonic 3.9 GHz Superconducting Accelerating Cavities at FLASH |
title_full_unstemmed | A Study of Beam Position Diagnostics with Beam-excited Dipole Higher Order Modes using a Downconverter Test Electronics in Third Harmonic 3.9 GHz Superconducting Accelerating Cavities at FLASH |
title_short | A Study of Beam Position Diagnostics with Beam-excited Dipole Higher Order Modes using a Downconverter Test Electronics in Third Harmonic 3.9 GHz Superconducting Accelerating Cavities at FLASH |
title_sort | study of beam position diagnostics with beam-excited dipole higher order modes using a downconverter test electronics in third harmonic 3.9 ghz superconducting accelerating cavities at flash |
topic | Accelerators and Storage Rings 10: SC RF technology for higher intensity proton accelerators and higher energy electron linacs |
url | http://cds.cern.ch/record/1550975 http://cds.cern.ch/record/1550975 |
work_keys_str_mv | AT zhangp astudyofbeampositiondiagnosticswithbeamexciteddipolehigherordermodesusingadownconvertertestelectronicsinthirdharmonic39ghzsuperconductingacceleratingcavitiesatflash AT baboin astudyofbeampositiondiagnosticswithbeamexciteddipolehigherordermodesusingadownconvertertestelectronicsinthirdharmonic39ghzsuperconductingacceleratingcavitiesatflash AT eddyn astudyofbeampositiondiagnosticswithbeamexciteddipolehigherordermodesusingadownconvertertestelectronicsinthirdharmonic39ghzsuperconductingacceleratingcavitiesatflash AT fellenzb astudyofbeampositiondiagnosticswithbeamexciteddipolehigherordermodesusingadownconvertertestelectronicsinthirdharmonic39ghzsuperconductingacceleratingcavitiesatflash AT jonesrm astudyofbeampositiondiagnosticswithbeamexciteddipolehigherordermodesusingadownconvertertestelectronicsinthirdharmonic39ghzsuperconductingacceleratingcavitiesatflash AT lorbeerb astudyofbeampositiondiagnosticswithbeamexciteddipolehigherordermodesusingadownconvertertestelectronicsinthirdharmonic39ghzsuperconductingacceleratingcavitiesatflash AT wamsatt astudyofbeampositiondiagnosticswithbeamexciteddipolehigherordermodesusingadownconvertertestelectronicsinthirdharmonic39ghzsuperconductingacceleratingcavitiesatflash AT wendtm astudyofbeampositiondiagnosticswithbeamexciteddipolehigherordermodesusingadownconvertertestelectronicsinthirdharmonic39ghzsuperconductingacceleratingcavitiesatflash AT zhangp studyofbeampositiondiagnosticswithbeamexciteddipolehigherordermodesusingadownconvertertestelectronicsinthirdharmonic39ghzsuperconductingacceleratingcavitiesatflash AT baboin studyofbeampositiondiagnosticswithbeamexciteddipolehigherordermodesusingadownconvertertestelectronicsinthirdharmonic39ghzsuperconductingacceleratingcavitiesatflash AT eddyn studyofbeampositiondiagnosticswithbeamexciteddipolehigherordermodesusingadownconvertertestelectronicsinthirdharmonic39ghzsuperconductingacceleratingcavitiesatflash AT fellenzb studyofbeampositiondiagnosticswithbeamexciteddipolehigherordermodesusingadownconvertertestelectronicsinthirdharmonic39ghzsuperconductingacceleratingcavitiesatflash AT jonesrm studyofbeampositiondiagnosticswithbeamexciteddipolehigherordermodesusingadownconvertertestelectronicsinthirdharmonic39ghzsuperconductingacceleratingcavitiesatflash AT lorbeerb studyofbeampositiondiagnosticswithbeamexciteddipolehigherordermodesusingadownconvertertestelectronicsinthirdharmonic39ghzsuperconductingacceleratingcavitiesatflash AT wamsatt studyofbeampositiondiagnosticswithbeamexciteddipolehigherordermodesusingadownconvertertestelectronicsinthirdharmonic39ghzsuperconductingacceleratingcavitiesatflash AT wendtm studyofbeampositiondiagnosticswithbeamexciteddipolehigherordermodesusingadownconvertertestelectronicsinthirdharmonic39ghzsuperconductingacceleratingcavitiesatflash |