Cargando…
Development of a Cavity Beam Position Monitor for CLIC
The Compact Linear Collider (CLIC) project presents many challenges to its subsystems and the beam diagnostics in particular must perform beyond current limitations. The requirements for the CLIC main beam position monitors foresee a spacial resolution of 50 nm while delivering a 50 ns temporal reso...
Autores principales: | , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2012
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1558308 |
_version_ | 1780930570273947648 |
---|---|
author | Cullinan, F Boogert, S T Joshi, N Lyapin, A Calvo, E Chritin, N Guillot-Vignot, F Lefevre, T Søby, L Lunin, A Wendt, M Yakovlev, V P Smith, S |
author_facet | Cullinan, F Boogert, S T Joshi, N Lyapin, A Calvo, E Chritin, N Guillot-Vignot, F Lefevre, T Søby, L Lunin, A Wendt, M Yakovlev, V P Smith, S |
author_sort | Cullinan, F |
collection | CERN |
description | The Compact Linear Collider (CLIC) project presents many challenges to its subsystems and the beam diagnostics in particular must perform beyond current limitations. The requirements for the CLIC main beam position monitors foresee a spacial resolution of 50 nm while delivering a 50 ns temporal resolution within the bunch train. We discuss the design of the microwave cavity pick-up and associated electronics, bench top tests with the first prototype cavity, as well as some of the machine-specific integration and operational issues. |
id | cern-1558308 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2012 |
record_format | invenio |
spelling | cern-15583082019-09-30T06:29:59Zhttp://cds.cern.ch/record/1558308engCullinan, FBoogert, S TJoshi, NLyapin, ACalvo, EChritin, NGuillot-Vignot, FLefevre, TSøby, LLunin, AWendt, MYakovlev, V PSmith, SDevelopment of a Cavity Beam Position Monitor for CLICAccelerators and Storage RingsThe Compact Linear Collider (CLIC) project presents many challenges to its subsystems and the beam diagnostics in particular must perform beyond current limitations. The requirements for the CLIC main beam position monitors foresee a spacial resolution of 50 nm while delivering a 50 ns temporal resolution within the bunch train. We discuss the design of the microwave cavity pick-up and associated electronics, bench top tests with the first prototype cavity, as well as some of the machine-specific integration and operational issues.oai:cds.cern.ch:15583082012 |
spellingShingle | Accelerators and Storage Rings Cullinan, F Boogert, S T Joshi, N Lyapin, A Calvo, E Chritin, N Guillot-Vignot, F Lefevre, T Søby, L Lunin, A Wendt, M Yakovlev, V P Smith, S Development of a Cavity Beam Position Monitor for CLIC |
title | Development of a Cavity Beam Position Monitor for CLIC |
title_full | Development of a Cavity Beam Position Monitor for CLIC |
title_fullStr | Development of a Cavity Beam Position Monitor for CLIC |
title_full_unstemmed | Development of a Cavity Beam Position Monitor for CLIC |
title_short | Development of a Cavity Beam Position Monitor for CLIC |
title_sort | development of a cavity beam position monitor for clic |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/1558308 |
work_keys_str_mv | AT cullinanf developmentofacavitybeampositionmonitorforclic AT boogertst developmentofacavitybeampositionmonitorforclic AT joshin developmentofacavitybeampositionmonitorforclic AT lyapina developmentofacavitybeampositionmonitorforclic AT calvoe developmentofacavitybeampositionmonitorforclic AT chritinn developmentofacavitybeampositionmonitorforclic AT guillotvignotf developmentofacavitybeampositionmonitorforclic AT lefevret developmentofacavitybeampositionmonitorforclic AT søbyl developmentofacavitybeampositionmonitorforclic AT lunina developmentofacavitybeampositionmonitorforclic AT wendtm developmentofacavitybeampositionmonitorforclic AT yakovlevvp developmentofacavitybeampositionmonitorforclic AT smiths developmentofacavitybeampositionmonitorforclic |