Cargando…

Development of a Cavity Beam Position Monitor for CLIC

The Compact Linear Collider (CLIC) project presents many challenges to its subsystems and the beam diagnostics in particular must perform beyond current limitations. The requirements for the CLIC main beam position monitors foresee a spacial resolution of 50 nm while delivering a 50 ns temporal reso...

Descripción completa

Detalles Bibliográficos
Autores principales: Cullinan, F, Boogert, S T, Joshi, N, Lyapin, A, Calvo, E, Chritin, N, Guillot-Vignot, F, Lefevre, T, Søby, L, Lunin, A, Wendt, M, Yakovlev, V P, Smith, S
Lenguaje:eng
Publicado: 2012
Materias:
Acceso en línea:http://cds.cern.ch/record/1558308
_version_ 1780930570273947648
author Cullinan, F
Boogert, S T
Joshi, N
Lyapin, A
Calvo, E
Chritin, N
Guillot-Vignot, F
Lefevre, T
Søby, L
Lunin, A
Wendt, M
Yakovlev, V P
Smith, S
author_facet Cullinan, F
Boogert, S T
Joshi, N
Lyapin, A
Calvo, E
Chritin, N
Guillot-Vignot, F
Lefevre, T
Søby, L
Lunin, A
Wendt, M
Yakovlev, V P
Smith, S
author_sort Cullinan, F
collection CERN
description The Compact Linear Collider (CLIC) project presents many challenges to its subsystems and the beam diagnostics in particular must perform beyond current limitations. The requirements for the CLIC main beam position monitors foresee a spacial resolution of 50 nm while delivering a 50 ns temporal resolution within the bunch train. We discuss the design of the microwave cavity pick-up and associated electronics, bench top tests with the first prototype cavity, as well as some of the machine-specific integration and operational issues.
id cern-1558308
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2012
record_format invenio
spelling cern-15583082019-09-30T06:29:59Zhttp://cds.cern.ch/record/1558308engCullinan, FBoogert, S TJoshi, NLyapin, ACalvo, EChritin, NGuillot-Vignot, FLefevre, TSøby, LLunin, AWendt, MYakovlev, V PSmith, SDevelopment of a Cavity Beam Position Monitor for CLICAccelerators and Storage RingsThe Compact Linear Collider (CLIC) project presents many challenges to its subsystems and the beam diagnostics in particular must perform beyond current limitations. The requirements for the CLIC main beam position monitors foresee a spacial resolution of 50 nm while delivering a 50 ns temporal resolution within the bunch train. We discuss the design of the microwave cavity pick-up and associated electronics, bench top tests with the first prototype cavity, as well as some of the machine-specific integration and operational issues.oai:cds.cern.ch:15583082012
spellingShingle Accelerators and Storage Rings
Cullinan, F
Boogert, S T
Joshi, N
Lyapin, A
Calvo, E
Chritin, N
Guillot-Vignot, F
Lefevre, T
Søby, L
Lunin, A
Wendt, M
Yakovlev, V P
Smith, S
Development of a Cavity Beam Position Monitor for CLIC
title Development of a Cavity Beam Position Monitor for CLIC
title_full Development of a Cavity Beam Position Monitor for CLIC
title_fullStr Development of a Cavity Beam Position Monitor for CLIC
title_full_unstemmed Development of a Cavity Beam Position Monitor for CLIC
title_short Development of a Cavity Beam Position Monitor for CLIC
title_sort development of a cavity beam position monitor for clic
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/1558308
work_keys_str_mv AT cullinanf developmentofacavitybeampositionmonitorforclic
AT boogertst developmentofacavitybeampositionmonitorforclic
AT joshin developmentofacavitybeampositionmonitorforclic
AT lyapina developmentofacavitybeampositionmonitorforclic
AT calvoe developmentofacavitybeampositionmonitorforclic
AT chritinn developmentofacavitybeampositionmonitorforclic
AT guillotvignotf developmentofacavitybeampositionmonitorforclic
AT lefevret developmentofacavitybeampositionmonitorforclic
AT søbyl developmentofacavitybeampositionmonitorforclic
AT lunina developmentofacavitybeampositionmonitorforclic
AT wendtm developmentofacavitybeampositionmonitorforclic
AT yakovlevvp developmentofacavitybeampositionmonitorforclic
AT smiths developmentofacavitybeampositionmonitorforclic