Study of Transverse Pulse-to-Pulse Orbit Jitter at the KEK Accelerator Test Facility 2 (ATF2)
For future linear colliders the precise control and mitigation of pulse-to-pulse orbit jitter will be very important to achieve the required luminosity. Diagnostic techniques for the orbit jitter measurement and correction for multibunch operation are being addressed at the KEK Accelerator Test Faci...
Autores principales: | , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2012
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1558311 |
_version_ | 1780930570491002880 |
---|---|
author | Resta-Lopez, J Alabau-Gonzalvo, J Bett, D R Burrows, P N Christian, G B Davis, M R Perry, C Apsimon, R Constance, B Gerbershagen, A |
author_facet | Resta-Lopez, J Alabau-Gonzalvo, J Bett, D R Burrows, P N Christian, G B Davis, M R Perry, C Apsimon, R Constance, B Gerbershagen, A |
author_sort | Resta-Lopez, J |
collection | CERN |
description | For future linear colliders the precise control and mitigation of pulse-to-pulse orbit jitter will be very important to achieve the required luminosity. Diagnostic techniques for the orbit jitter measurement and correction for multibunch operation are being addressed at the KEK Accelerator Test Facility 2 (ATF2). In this paper we present recent studies on the vertical jitter propagation through the ATF2 extraction line and final focus system. For these studies the vertical pulse-to-pulse position and angle jitter have been measured using the available stripline beam position monitors in the beamline. The cases with and without intra-train orbit feedback correction in the ATF2 extraction line are compared. I |
id | cern-1558311 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2012 |
record_format | invenio |
spelling | cern-15583112019-09-30T06:29:59Zhttp://cds.cern.ch/record/1558311engResta-Lopez, JAlabau-Gonzalvo, JBett, D RBurrows, P NChristian, G BDavis, M RPerry, CApsimon, RConstance, BGerbershagen, AStudy of Transverse Pulse-to-Pulse Orbit Jitter at the KEK Accelerator Test Facility 2 (ATF2)Accelerators and Storage RingsFor future linear colliders the precise control and mitigation of pulse-to-pulse orbit jitter will be very important to achieve the required luminosity. Diagnostic techniques for the orbit jitter measurement and correction for multibunch operation are being addressed at the KEK Accelerator Test Facility 2 (ATF2). In this paper we present recent studies on the vertical jitter propagation through the ATF2 extraction line and final focus system. For these studies the vertical pulse-to-pulse position and angle jitter have been measured using the available stripline beam position monitors in the beamline. The cases with and without intra-train orbit feedback correction in the ATF2 extraction line are compared. Ioai:cds.cern.ch:15583112012 |
spellingShingle | Accelerators and Storage Rings Resta-Lopez, J Alabau-Gonzalvo, J Bett, D R Burrows, P N Christian, G B Davis, M R Perry, C Apsimon, R Constance, B Gerbershagen, A Study of Transverse Pulse-to-Pulse Orbit Jitter at the KEK Accelerator Test Facility 2 (ATF2) |
title | Study of Transverse Pulse-to-Pulse Orbit Jitter at the KEK Accelerator Test Facility 2 (ATF2) |
title_full | Study of Transverse Pulse-to-Pulse Orbit Jitter at the KEK Accelerator Test Facility 2 (ATF2) |
title_fullStr | Study of Transverse Pulse-to-Pulse Orbit Jitter at the KEK Accelerator Test Facility 2 (ATF2) |
title_full_unstemmed | Study of Transverse Pulse-to-Pulse Orbit Jitter at the KEK Accelerator Test Facility 2 (ATF2) |
title_short | Study of Transverse Pulse-to-Pulse Orbit Jitter at the KEK Accelerator Test Facility 2 (ATF2) |
title_sort | study of transverse pulse-to-pulse orbit jitter at the kek accelerator test facility 2 (atf2) |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/1558311 |
work_keys_str_mv | AT restalopezj studyoftransversepulsetopulseorbitjitteratthekekacceleratortestfacility2atf2 AT alabaugonzalvoj studyoftransversepulsetopulseorbitjitteratthekekacceleratortestfacility2atf2 AT bettdr studyoftransversepulsetopulseorbitjitteratthekekacceleratortestfacility2atf2 AT burrowspn studyoftransversepulsetopulseorbitjitteratthekekacceleratortestfacility2atf2 AT christiangb studyoftransversepulsetopulseorbitjitteratthekekacceleratortestfacility2atf2 AT davismr studyoftransversepulsetopulseorbitjitteratthekekacceleratortestfacility2atf2 AT perryc studyoftransversepulsetopulseorbitjitteratthekekacceleratortestfacility2atf2 AT apsimonr studyoftransversepulsetopulseorbitjitteratthekekacceleratortestfacility2atf2 AT constanceb studyoftransversepulsetopulseorbitjitteratthekekacceleratortestfacility2atf2 AT gerbershagena studyoftransversepulsetopulseorbitjitteratthekekacceleratortestfacility2atf2 |