Measuring the bunch frequency multiplication at the 3rd CLIC Test Facility
The CLIC Test Facility 3 (CTF3) is being built and commissioned by an international collaboration to test the feasibility of the proposed Compact Linear Collider (CLIC) drive beam generation scheme. Central to this scheme is the use of RF deflectors to inject bunches into a delay loop and a combiner...
Autores principales: | , , , , , , , , , , , , |
---|---|
Publicado: |
2012
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1088/1748-0221/7/01/P01005 http://cds.cern.ch/record/1559803 |
_version_ | 1780930654068801536 |
---|---|
author | Dabrowski, AE Bettoni, S Bravin, E Corsini, R Dobert, S Lefevre, T Rabiller, A Soby, L Skowronski, P K Tecker, F Egger, D Ferrari, A Welsch, C P |
author_facet | Dabrowski, AE Bettoni, S Bravin, E Corsini, R Dobert, S Lefevre, T Rabiller, A Soby, L Skowronski, P K Tecker, F Egger, D Ferrari, A Welsch, C P |
author_sort | Dabrowski, AE |
collection | CERN |
description | The CLIC Test Facility 3 (CTF3) is being built and commissioned by an international collaboration to test the feasibility of the proposed Compact Linear Collider (CLIC) drive beam generation scheme. Central to this scheme is the use of RF deflectors to inject bunches into a delay loop and a combiner ring, in order to transform the initial bunch frequency of 1.5 GHz from the linac to a final bunch frequency of 12 GHz. To do so, the machine's transverse optics must be tuned to ensure beam isochronicity and each ring's length can finally be adjusted with wiggler magnets to a sub millimeter path length accuracy. Diagnostics based on optical streak camera and RF power measurements, in particular frequency bands, have been designed to measure the longitudinal behaviour of the beam during the combination. This paper presents the diagnostics and recent commissioning measurements. |
id | cern-1559803 |
institution | Organización Europea para la Investigación Nuclear |
publishDate | 2012 |
record_format | invenio |
spelling | cern-15598032019-09-30T06:29:59Zdoi:10.1088/1748-0221/7/01/P01005http://cds.cern.ch/record/1559803Dabrowski, AEBettoni, SBravin, ECorsini, RDobert, SLefevre, TRabiller, ASoby, LSkowronski, P KTecker, FEgger, DFerrari, AWelsch, C PMeasuring the bunch frequency multiplication at the 3rd CLIC Test FacilityAccelerators and Storage RingsThe CLIC Test Facility 3 (CTF3) is being built and commissioned by an international collaboration to test the feasibility of the proposed Compact Linear Collider (CLIC) drive beam generation scheme. Central to this scheme is the use of RF deflectors to inject bunches into a delay loop and a combiner ring, in order to transform the initial bunch frequency of 1.5 GHz from the linac to a final bunch frequency of 12 GHz. To do so, the machine's transverse optics must be tuned to ensure beam isochronicity and each ring's length can finally be adjusted with wiggler magnets to a sub millimeter path length accuracy. Diagnostics based on optical streak camera and RF power measurements, in particular frequency bands, have been designed to measure the longitudinal behaviour of the beam during the combination. This paper presents the diagnostics and recent commissioning measurements.oai:cds.cern.ch:15598032012 |
spellingShingle | Accelerators and Storage Rings Dabrowski, AE Bettoni, S Bravin, E Corsini, R Dobert, S Lefevre, T Rabiller, A Soby, L Skowronski, P K Tecker, F Egger, D Ferrari, A Welsch, C P Measuring the bunch frequency multiplication at the 3rd CLIC Test Facility |
title | Measuring the bunch frequency multiplication at the 3rd CLIC Test Facility |
title_full | Measuring the bunch frequency multiplication at the 3rd CLIC Test Facility |
title_fullStr | Measuring the bunch frequency multiplication at the 3rd CLIC Test Facility |
title_full_unstemmed | Measuring the bunch frequency multiplication at the 3rd CLIC Test Facility |
title_short | Measuring the bunch frequency multiplication at the 3rd CLIC Test Facility |
title_sort | measuring the bunch frequency multiplication at the 3rd clic test facility |
topic | Accelerators and Storage Rings |
url | https://dx.doi.org/10.1088/1748-0221/7/01/P01005 http://cds.cern.ch/record/1559803 |
work_keys_str_mv | AT dabrowskiae measuringthebunchfrequencymultiplicationatthe3rdclictestfacility AT bettonis measuringthebunchfrequencymultiplicationatthe3rdclictestfacility AT bravine measuringthebunchfrequencymultiplicationatthe3rdclictestfacility AT corsinir measuringthebunchfrequencymultiplicationatthe3rdclictestfacility AT doberts measuringthebunchfrequencymultiplicationatthe3rdclictestfacility AT lefevret measuringthebunchfrequencymultiplicationatthe3rdclictestfacility AT rabillera measuringthebunchfrequencymultiplicationatthe3rdclictestfacility AT sobyl measuringthebunchfrequencymultiplicationatthe3rdclictestfacility AT skowronskipk measuringthebunchfrequencymultiplicationatthe3rdclictestfacility AT teckerf measuringthebunchfrequencymultiplicationatthe3rdclictestfacility AT eggerd measuringthebunchfrequencymultiplicationatthe3rdclictestfacility AT ferraria measuringthebunchfrequencymultiplicationatthe3rdclictestfacility AT welschcp measuringthebunchfrequencymultiplicationatthe3rdclictestfacility |