Experimental Verifiction of the CLIC two beam Acceleration Technology in CTF3

The Compact Linear Collider international collaboration is pursuing an extensive R&D program towards a multi- TeV electron-positron collider. In particular, the development of two-beam acceleration technology is the focus of the CLIC test facility CTF3. In this paper we summarise the most recent...

Descripción completa

Detalles Bibliográficos
Autores principales: Constance, B, Andersson, A, Barranco, J, Corsini, R, Doebert, S, Dubrovskiy, A, Skowronski, P, Tecker, F, Farabolini, W, Persson, T, Lillestol, R, Ikarios, E, Jacewicz, M, Palaia, A, Ruber, R
Lenguaje:eng
Publicado: 2013
Materias:
Acceso en línea:http://cds.cern.ch/record/1571163
Descripción
Sumario:The Compact Linear Collider international collaboration is pursuing an extensive R&D program towards a multi- TeV electron-positron collider. In particular, the development of two-beam acceleration technology is the focus of the CLIC test facility CTF3. In this paper we summarise the most recent results obtained at CTF3: the results of the studies on the drive beam generation are presented, the achieved two beam acceleration performance is reported and the measured breakdown rates and related observations are summarised. The stability of deceleration process performed over 12 subsequent modules and the comparison of the obtained results with the theoretical expectations are discussed. We also outline and discuss the future experimental program.