Cargando…

Characterization of 900 four-anode photomultiplier tubes for use in 2013 hadronic forward calorimeter upgrade.

The first 900 four-anode Photomultiplier Tubes (PMTs) have been evaluated for use in the 2013 Hadronic Forward (HF) calorimeter upgrade. HF is a part of the Compact Muon Solenoid (CMS), which is one of the two large general-purpose particle detectors of the Large Hadron Collider (LHC) at CERN in Gen...

Descripción completa

Detalles Bibliográficos
Autor principal: Tiras, Emrah
Lenguaje:eng
Publicado: 2013
Materias:
Acceso en línea:http://cds.cern.ch/record/1574445
_version_ 1780931045388976128
author Tiras, Emrah
author_facet Tiras, Emrah
author_sort Tiras, Emrah
collection CERN
description The first 900 four-anode Photomultiplier Tubes (PMTs) have been evaluated for use in the 2013 Hadronic Forward (HF) calorimeter upgrade. HF is a part of the Compact Muon Solenoid (CMS), which is one of the two large general-purpose particle detectors of the Large Hadron Collider (LHC) at CERN in Geneva, Switzerland. HF requires 1728 PMTs. These small tubes are the sensitive light detectors that provide the output signals of HF. Before installing PMTs in HF, their quality control demands need to be satisfied. These tests, done at the University of Iowa, are designed in three categories to test seventeen different parameters for each PMT. The three most basic and most important groups of parameters are: dark current, gain (anode and cathode), and timing. There are secondary tests which are performed on a smaller percentage of the PMTs such as surface uniformity, double pulse and single photo-electron resolution. The PMTs that meet the specifications of HF will be sent to CERN where they are expected to be in use for at least a decade.
id cern-1574445
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2013
record_format invenio
spelling cern-15744452019-09-30T06:29:59Zhttp://cds.cern.ch/record/1574445engTiras, EmrahCharacterization of 900 four-anode photomultiplier tubes for use in 2013 hadronic forward calorimeter upgrade.Detectors and Experimental TechniquesThe first 900 four-anode Photomultiplier Tubes (PMTs) have been evaluated for use in the 2013 Hadronic Forward (HF) calorimeter upgrade. HF is a part of the Compact Muon Solenoid (CMS), which is one of the two large general-purpose particle detectors of the Large Hadron Collider (LHC) at CERN in Geneva, Switzerland. HF requires 1728 PMTs. These small tubes are the sensitive light detectors that provide the output signals of HF. Before installing PMTs in HF, their quality control demands need to be satisfied. These tests, done at the University of Iowa, are designed in three categories to test seventeen different parameters for each PMT. The three most basic and most important groups of parameters are: dark current, gain (anode and cathode), and timing. There are secondary tests which are performed on a smaller percentage of the PMTs such as surface uniformity, double pulse and single photo-electron resolution. The PMTs that meet the specifications of HF will be sent to CERN where they are expected to be in use for at least a decade.CERN-THESIS-2012-337oai:cds.cern.ch:15744452013-08-13T17:36:54Z
spellingShingle Detectors and Experimental Techniques
Tiras, Emrah
Characterization of 900 four-anode photomultiplier tubes for use in 2013 hadronic forward calorimeter upgrade.
title Characterization of 900 four-anode photomultiplier tubes for use in 2013 hadronic forward calorimeter upgrade.
title_full Characterization of 900 four-anode photomultiplier tubes for use in 2013 hadronic forward calorimeter upgrade.
title_fullStr Characterization of 900 four-anode photomultiplier tubes for use in 2013 hadronic forward calorimeter upgrade.
title_full_unstemmed Characterization of 900 four-anode photomultiplier tubes for use in 2013 hadronic forward calorimeter upgrade.
title_short Characterization of 900 four-anode photomultiplier tubes for use in 2013 hadronic forward calorimeter upgrade.
title_sort characterization of 900 four-anode photomultiplier tubes for use in 2013 hadronic forward calorimeter upgrade.
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/1574445
work_keys_str_mv AT tirasemrah characterizationof900fouranodephotomultipliertubesforusein2013hadronicforwardcalorimeterupgrade