Estimate of Warm Magnets Lifetime in the Betatron and Momentum Cleaning Insertions of the LHC
The CERN LHC collimation system is designed to perform momentum and betatron cleaning in different insertions, respectively IR3 and IR7. The insertions are not perfectly decoupled because the dispersion in IR7 is not null and the beta function in IR3 is not zero. The detailed sharing of losses betwe...
Autores principales: | , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2013
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1574597 |
Sumario: | The CERN LHC collimation system is designed to perform momentum and betatron cleaning in different insertions, respectively IR3 and IR7. The insertions are not perfectly decoupled because the dispersion in IR7 is not null and the beta function in IR3 is not zero. The detailed sharing of losses between the two insertions depends on the relative collimator settings as observed by the change between 2011 and 2012 LHC operation. In this report, using the beam loss measurements at the primary collimators of IR3 and IR7, the total BLM losses in the two insertions are calculated and compared to each other. These studies are also used to quantify the total dose to warm magnets in those IRs with the aim to understand better their lifetime and the implications of the radiation to electronics. This will be of particular importance in view of LHC operating at nominal performance after several years of operation. |
---|