Radiation Protection Study for the Shielding Design of the LINAC4 Beam Dump at CERN
The aim of this study is to determine an optimal shielding of the LINAC4 beam dump fulfilling the radiation protection requirements. Therefore a detailed Monte-Carlo calculation using FLUKA particle transport and interaction code has been performed and the relevant physics quantities, such as partic...
Autores principales: | Blaha, Jan, Vollaire, Joachim |
---|---|
Lenguaje: | eng |
Publicado: |
2013
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1594959 |
Ejemplares similares
-
Shielding of an internal dumping facility for the PS; results of experiments in the SE 62 test beam and comparison with Monte Carlo calculations
por: Gouiran, R, et al.
Publicado: (1974) -
Gas bremsstrahlung considerations in the shielding design of the advanced photon source synchrotron radiation beam lines
por: Ipe, N E, et al.
Publicado: (1994) -
The handling equipment for the radiation shielding blocks of the CERN Proton Synchrotron
por: Achermann, A H
Publicado: (1958) -
21st Century Challenges in Radiation Protection and Shielding
Publicado: (2005) -
Radiation shielding
por: Shultis, J Kenneth, et al.
Publicado: (2000)