Loss of Landau Damping for Inductive Impedance in a Double RF System
In this paper the thresholds of the loss of Landau damping due to the presence of inductive impedance in a single and double harmonic RF systems are determined, both from calculations and particle simulations. A high harmonic RF system, operating in bunch lengthening mode is used in many accelerator...