This report discusses my project, as a summer student, in PH-DT-DI department at CERN. My study was about the operation of a single wire chamber. The final goal was the characterization of the detector performances versus time. The study aims in a future use of the single wire detector as a gas mixt...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2013
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1596279 |
_version_ | 1780931167574294528 |
---|---|
author | Vitoratou, Niki |
author_facet | Vitoratou, Niki |
author_sort | Vitoratou, Niki |
collection | CERN |
description | This report discusses my project, as a summer student, in PH-DT-DI department at CERN. My study was about the operation of a single wire chamber. The final goal was the characterization of the detector performances versus time. The study aims in a future use of the single wire detector as a gas mixture monitoring tool. After a first period of operation, where a worsening of the detector performances has been observed, some components were replaces and finally a stable operation was achieved allowing to validate the complete setup. A new single wire chamber has been built and it will soon replace the one used during the present study. A dedicated DAQ (VME, NIM, National Instrument) and data analysis (ROOT macros) system have been developed and the first results are here presented. |
id | cern-1596279 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2013 |
record_format | invenio |
spelling | cern-15962792019-09-30T06:29:59Zhttp://cds.cern.ch/record/1596279engVitoratou, NikiValidation of single wire proportional chamber for long term operationParticle Physics - ExperimentThis report discusses my project, as a summer student, in PH-DT-DI department at CERN. My study was about the operation of a single wire chamber. The final goal was the characterization of the detector performances versus time. The study aims in a future use of the single wire detector as a gas mixture monitoring tool. After a first period of operation, where a worsening of the detector performances has been observed, some components were replaces and finally a stable operation was achieved allowing to validate the complete setup. A new single wire chamber has been built and it will soon replace the one used during the present study. A dedicated DAQ (VME, NIM, National Instrument) and data analysis (ROOT macros) system have been developed and the first results are here presented.CERN-STUDENTS-Note-2013-155oai:cds.cern.ch:15962792013-08-30 |
spellingShingle | Particle Physics - Experiment Vitoratou, Niki Validation of single wire proportional chamber for long term operation |
title | Validation of single wire proportional chamber for long term operation |
title_full | Validation of single wire proportional chamber for long term operation |
title_fullStr | Validation of single wire proportional chamber for long term operation |
title_full_unstemmed | Validation of single wire proportional chamber for long term operation |
title_short | Validation of single wire proportional chamber for long term operation |
title_sort | validation of single wire proportional chamber for long term operation |
topic | Particle Physics - Experiment |
url | http://cds.cern.ch/record/1596279 |
work_keys_str_mv | AT vitoratouniki validationofsinglewireproportionalchamberforlongtermoperation |