Cargando…
LHCb: Upgrade of the LHCb calorimeter electronics
The LHCb collaboration foresees a major upgrade of the detector for the high luminosity run that should take place after 2018. Apart from the increase of the instantaneous luminosity at the interaction point of the experiment, one of the major ingredients of this upgrade is a full readout at 40MHz o...
Autores principales: | , |
---|---|
Lenguaje: | eng |
Publicado: |
2013
|
Acceso en línea: | http://cds.cern.ch/record/1605095 |
_version_ | 1780931617542373376 |
---|---|
author | Mauricio Ferre, J Machefert, F |
author_facet | Mauricio Ferre, J Machefert, F |
author_sort | Mauricio Ferre, J |
collection | CERN |
description | The LHCb collaboration foresees a major upgrade of the detector for the high luminosity run that should take place after 2018. Apart from the increase of the instantaneous luminosity at the interaction point of the experiment, one of the major ingredients of this upgrade is a full readout at 40MHz of the sub-detectors and the acquisition of the data by a large farm of PC. The trigger will be done by this farm and should increase the overall trigger efficiency with respect to the current detector, especially in hadronic B meson decays. A general overview of the modifications foreseen to the calorimeter system and the integration of the electromagnetic and hadronic calorimeters in this new scheme will be described. |
id | cern-1605095 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2013 |
record_format | invenio |
spelling | cern-16050952019-09-30T06:29:59Zhttp://cds.cern.ch/record/1605095engMauricio Ferre, JMachefert, FLHCb: Upgrade of the LHCb calorimeter electronicsThe LHCb collaboration foresees a major upgrade of the detector for the high luminosity run that should take place after 2018. Apart from the increase of the instantaneous luminosity at the interaction point of the experiment, one of the major ingredients of this upgrade is a full readout at 40MHz of the sub-detectors and the acquisition of the data by a large farm of PC. The trigger will be done by this farm and should increase the overall trigger efficiency with respect to the current detector, especially in hadronic B meson decays. A general overview of the modifications foreseen to the calorimeter system and the integration of the electromagnetic and hadronic calorimeters in this new scheme will be described.Poster-2013-284oai:cds.cern.ch:16050952013-09-25 |
spellingShingle | Mauricio Ferre, J Machefert, F LHCb: Upgrade of the LHCb calorimeter electronics |
title | LHCb: Upgrade of the LHCb calorimeter electronics |
title_full | LHCb: Upgrade of the LHCb calorimeter electronics |
title_fullStr | LHCb: Upgrade of the LHCb calorimeter electronics |
title_full_unstemmed | LHCb: Upgrade of the LHCb calorimeter electronics |
title_short | LHCb: Upgrade of the LHCb calorimeter electronics |
title_sort | lhcb: upgrade of the lhcb calorimeter electronics |
url | http://cds.cern.ch/record/1605095 |
work_keys_str_mv | AT mauricioferrej lhcbupgradeofthelhcbcalorimeterelectronics AT machefertf lhcbupgradeofthelhcbcalorimeterelectronics |